Difference between revisions of "Mammography Acquisition Workflow"

From IHE Wiki
Jump to navigation Jump to search
Line 50: Line 50:
 
'''Documents:'''  
 
'''Documents:'''  
  
''<Provide direct links to the specific volumes or supplements, and list the volume sections relevant to this profile.  This is a simple inventory of official normative and informative text.  If you would like to provide a reading guide or walkthrough of what is in each of the different sections for implementers or users, do that in the Profile FAQ or the Profile Implementation Page linked below.  If the profile uses transactions from multiple Tech. Frameworks, repeat the structure below.>''
 
  
[http://www.ihe.net/Technical_Framework/index.cfm#radiology IHE Radiology Technical Framework:]
+
[http://www.ihe.net/Technical_Framework/upload/IHE-RAD_TF_Suppl_Mammo-Acquisition-Workflow_TI_2008-07-03.pdf Supplement MAWF]
:* [http://www.ihe.net/Technical_Framework/upload/ihe_tf_rev8.pdf Vol. 1] - Section 5 (SWF Profile)
+
 
:* [http://www.ihe.net/Technical_Framework/upload/ihe_tf_rev8-2.pdf Vol. 2] - Sections 4.8 to 4.10, 4.14 to 4.19, and 4.23
 
:* [http://www.ihe.net/Technical_Framework/upload/ihe_tf_rev8-3.pdf Vol. 3] - Appendix E
 
  
 
'''Underlying Standards:'''
 
'''Underlying Standards:'''
  
''<list all the standards on which the profile is based; if possible with links to sources>''
 
 
:* [http://dicom.nema.org DICOM]
 
:* [http://dicom.nema.org DICOM]
 
:* [http://www.hl7.org HL7]
 
:* [http://www.hl7.org HL7]
Line 66: Line 62:
 
==See Also==
 
==See Also==
  
''<The following sections can be left out if there is nothing to point to.  This is just to show where such information can go.>''
+
 
  
  
 
'''Related Profiles'''
 
'''Related Profiles'''
  
''<List profiles this one depends on, profiles that depend on this one, profiles that are synergistic with this one.  Start with the name of the other profile as a link and then explain the relationship.>''
 
  
* ''[[Reporting Workflow]] [RWF] may use Evidence Documents as inputs to the reporting process.''
+
 
* ''[[Simple Image & Numeric Reports]] [SINR] may include data copied from Evidence Documents.''
+
* ''[[Scheduled Workflow]] [SWF] required for workflow management.''
* ''[[Cross-enterprise Document Sharing for Imaging]] [XDS-I] can be used to share Evidence Documents between sites over a network.''
+
* ''[[Mammography Image]] [MAMMO] required for content creation and presentation of mammography images.''
* ''[[Portable Data for Imaging]] [PDI] can store Evidence Documents on media such as CDs.''
+
* ''[[Key Image Note]] [KIN] uses same mechanism for marking images in a study.''
* ''[[Import Reconciliation Workflow]] [IRWF] can fix patient ids, etc. of Evidence Documents when importing.''
 
  
  
 
'''Consumer Information'''
 
'''Consumer Information'''
  
The [[Profile FAQ Template]] answers typical questions about what the Profile does.  ''<Replace the link with a link to the actual FAQ page for the Profile>''
+
The [[Profile FAQ Template]] answers typical questions about what the Profile does.   
  
The [[Profile Purchasing Template]] describes considerations when purchasing equipment to deploy this Profile.  ''<Replace the link with a link to the actual Purchasing page for the Profile>''
+
The [[Profile Purchasing Template]] describes considerations when purchasing equipment to deploy this Profile.   
  
 
'''Implementer Information'''
 
'''Implementer Information'''
  
The [[Profile Implementation Template]] provides additional information about implementing this Profile in software.  ''<Replace the link with a link to the actual Implementation page for the Profile>''
+
The [[Profile Implementation Template]] provides additional information about implementing this Profile in software.   
  
 
'''Reference Articles'''
 
'''Reference Articles'''

Revision as of 05:25, 3 March 2010

Mammography Acquisition Workflow handles mammography-specific exceptions to routine image acquisition based on Scheduled Workflow.

Summary

Mammography Acquisition Workflow defines how Mammography Modalities or Workstations reject images for quality reasons or correct view information in images. It furthermore describes how to document procedure and protocol changes as well as recall cases. The Department System Scheduler and Image Archive will keep its internal information consistent with these changes. The Reading Workstations present original and recall studies together.

Mawf-v1.jpg

Benefits

Reduce Errors and Enhance Patient Care

  • Prevents additional exposure due to wrong labeling
  • Prevents delays in patient care by making relevant information available at the point of care.

Improve Throughput

  • Reduces staff time wasted identifying and correcting errors (in a coordinated fashion) among the HIS, RIS, PACS and modality

Reduce Deployment Cost/Time

  • Prevents custom interface specification time and expense—IHE TF provides a detailed specification for a powerful interface, supported and tested by many vendors
  • Prevents custom interface implementation time and expense—many IHE Integration Profiles are already supported by many vendor products
  • Reduces interface compliance testing time and expense—many implementation variations have been refined in systems tested at IHE Connectathons
  • Reduces intersystem testing time and expense—many combinations of systems have already been directly tested together at IHE Connectathons
  • Reduces custom interface maintenance time and expense by maintaining a single interface (IHE) instead of multiple custom interfaces


Details

The Mammography Acquisition Workflow (MAWF) Integration Profile describes

  • Rejection of images for quality reasons: After completed examination, some images are considered to be of low quality or not useful for interpretation and further use.
  • Correction of image view and laterality: After completed examination, the Tech notices incorrect labels in a view. The view shall be corrected and „updated“ in PACS / RIS.

Example: L instead of R, CC instead of MLO.

  • Unambigous coding of screening (technical) recalls, so that reading workstations can present recall cases together with the original study.
  • Procedure Updates performed at the modality.

Systems Affected

Systems involved in this profile are:

  • Mammography acquisition modalities creating and correcting images
  • Mammography reading workstations
  • Radiology departmental information systems that manage department scheduling (i.e., radiology information system (RIS))
  • Radiology image management/archiving (i.e., picture archiving and communication system (PACS)) storing and/or hiding old images

Actors & Transactions:

Mawf-actor-transaction.JPG

Specification

Profile Status: Trail Implementation

Documents:


Supplement MAWF


Underlying Standards:

See Also

Related Profiles



Consumer Information

The Profile FAQ Template answers typical questions about what the Profile does.

The Profile Purchasing Template describes considerations when purchasing equipment to deploy this Profile.

Implementer Information

The Profile Implementation Template provides additional information about implementing this Profile in software.

Reference Articles

<List References (good and bad) (with link if possible) to Journal Articles that mention IHE's work (and hopefully include some analysis). Go ahead, Google: IHE <Profile Name> abstract or Google: IHE <Profile Name> and under the "more" select "Scholar". You might be surprised. >

This page is based on the Profile Overview Template