Laboratory Code Sets Distribution: Difference between revisions
| Line 16: | Line 16: | ||
The '''''Laboratory Code Sets Distribution (LCSD)Integration Profile''''' covers this use case: | The '''''Laboratory Code Sets Distribution (LCSD)Integration Profile''''' covers this use case: | ||
* . | * The system owning a laboratory code set - the Code Set Master Actor - sends the whole code set to any Code Set Consumer Actor, each time an update on this code set is needed.<br/> | ||
The LCSD Integration Profile defines a single Transaction, based on HL7 release 2.5 or 2.5.1 messaging standard, namely the "master file notification" messages "MFN": | The LCSD Integration Profile defines a single Transaction, based on HL7 release 2.5 or 2.5.1 messaging standard, namely the "master file notification" messages "MFN": | ||
* LAB-51 Laboratory Code Set Management | * LAB-51 Laboratory Code Set Management. This transaction provides the set of MFN messages that enable to replace wholy the current version of a code set with a new version. | ||
<br/> | <br/> | ||
Revision as of 04:25, 28 March 2008
Laboratory Code Sets Distribution (LCSD) Integration Profile supports.
Summary
A set of common codes is generally used by multiple application systems in a laboratory workflow environment. These common codes need to be synchronized across the various applications at a given site. In many implementations, one application system will be the author (the "master") of the code set. The responsibility for managing a code set may also be distributed among different systems. This profile provides a way for the master of a code set (battery, test and observation codes) to send the code set to other applications.
Benefits
Favors independence of
- .
Details
The Laboratory Code Sets Distribution (LCSD)Integration Profile covers this use case:
- The system owning a laboratory code set - the Code Set Master Actor - sends the whole code set to any Code Set Consumer Actor, each time an update on this code set is needed.
The LCSD Integration Profile defines a single Transaction, based on HL7 release 2.5 or 2.5.1 messaging standard, namely the "master file notification" messages "MFN":
- LAB-51 Laboratory Code Set Management. This transaction provides the set of MFN messages that enable to replace wholy the current version of a code set with a new version.
Systems Affected
Systems involved in this profile can be any of the systems involved in the workflow profiles of the Laboratory Technical Framework (LTW, LPOCT, LDA, LBL). One system plays the role of the Code Set Master and another system plays the role of the Code Set Consumer
Actors & Transactions:
Specification
Profile Status: Trial Implementation
Documents:
Underlying Standards:
See Also
Related Profiles
The Integration Profile LCSD can be leveraged by any of the workflow profiles of the Laboratory Technical Framework, that is: LTW, LDA, LPOCT, LBL
Consumer Information
This page is based on the Profile Template