| Line 43: |
Line 43: |
| ==See Also== | | ==See Also== |
|
| |
|
| ''<The following sections can be left out if there is nothing to point to. This is just to show where such information can go.>''
| |
|
| |
|
| |
| '''Related Profiles'''
| |
|
| |
| ''<List profiles this one depends on, profiles that depend on this one, profiles that are synergistic with this one. Start with the name of the other profile as a link and then explain the relationship.>''
| |
|
| |
| * ''[[Reporting Workflow]] [RWF] may use Evidence Documents as inputs to the reporting process.''
| |
| * ''[[Simple Image & Numeric Reports]] [SINR] may include data copied from Evidence Documents.''
| |
| * ''[[Cross-enterprise Document Sharing for Imaging]] [XDS-I] can be used to share Evidence Documents between sites over a network.''
| |
| * ''[[Portable Data for Imaging]] [PDI] can store Evidence Documents on media such as CDs.''
| |
| * ''[[Import Reconciliation Workflow]] [IRWF] can fix patient ids, etc. of Evidence Documents when importing.''
| |
|
| |
|
| |
| '''Consumer Information'''
| |
|
| |
| The [[Profile FAQ Template]] answers typical questions about what the Profile does. ''<Replace the link with a link to the actual FAQ page for the Profile>''
| |
|
| |
| The [[Profile Purchasing Template]] describes considerations when purchasing equipment to deploy this Profile. ''<Replace the link with a link to the actual Purchasing page for the Profile>''
| |
|
| |
| '''Implementer Information'''
| |
|
| |
| The [[Profile Implementation Template]] provides additional information about implementing this Profile in software. ''<Replace the link with a link to the actual Implementation page for the Profile>''
| |
|
| |
| '''Reference Articles'''
| |
|
| |
| ''<List References (good and bad) (with link if possible) to Journal Articles that mention IHE's work (and hopefully include some analysis). Go ahead, Google: IHE <Profile Name> abstract or Google: IHE <Profile Name> and under the "more" select "Scholar". You might be surprised. >''
| |
|
| |
|
|
| |
|
| Line 78: |
Line 51: |
| [[Category:RO Profile]] | | [[Category:RO Profile]] |
| [[Category:DICOM]] | | [[Category:DICOM]] |
| [[Category:RO todo]]
| |
Revision as of 11:13, 28 December 2023
Summary
This profile will ensure that the plan transferred from the Treatment Management System to the Delivery Device
will contain all of the necessary information.
This includes the definition of all beam parameters (including
Machine, energies, SSD, beam anatomical names, Couch, wedge, bolus details, meters values, collimation, gantry
start/ stop, block/ MLC, Cutout for electrons, accessories etc.) and should also include additional information, for
example patient identification - barcodes that incorporates MR # and Date of Birth treatment setup photos, set
up parameters, patient face photo, a screen shot of CT isocenter placement for reference etc.
Benefits
Standardizes the content which can be expected by the delivery
device and will provide clear advice to implementers. The profile will not specify how to validate the machine
parameters, but will ensure that they are available and well-formatted. The applications involved are Treatment
Management Systems and Delivery Devices.
Details
Systems Affected
- Treatment Management Systems (TMS).
- Treatment Delivery Devices (TDD)
Actors & Transactions:
Specification
Profile Status: Trial Implementation
Documents:
Underlying Standards:
See Also
This page is based on the Profile Overview Template