:'''Chair/Host:'''  ''Kurt Elliason (Smiths Medical)''
:'''Chair/Host:'''  ''Kurt Elliason (Smiths Medical)''


:'''Participants:'''  ''  
:'''Participants:'''  '' Al Engelbert (BBraun), Andrea Robertson (Smiths), Brian Witkowski (BBraun), Jeff Rinda (Interoperability Solutions), Marufur Rahmen (ICU), Paul Schluter (CMI), Shantanu Chawla (BD), Tom Kowalczyk (BBraun) 




Line 66: Line 66:
| '''Discussion of FHIR based approach to pump programming''' <br>- Brian W.
| '''Discussion of FHIR based approach to pump programming''' <br>- Brian W.
| '''Status/Discussion:'''
| '''Status/Discussion:'''
 
::Deferred to future meeting


'''Decisions/Issues:'''
'''Decisions/Issues:'''
Line 79: Line 79:
| '''Status/Discussion:'''
| '''Status/Discussion:'''
:CP for position in Pillar/Tower-Rack-Slot
:CP for position in Pillar/Tower-Rack-Slot
:CP to document which terms are under the MDS if it is a Rack and which terms are under the pump's VMD. Provide a picture.
:BBRaun reports Pillar number and slots in pillar
:Discussed option to create specific OBX’s for each.  Eg.
:: MDC_ATTR_RACK_INDEX – String - Left, Right, Top, Bottom
:: MDC_ATTR_RACK_POSITION – String - Left, Right, Top, Bottom, Center  -- RACK MDS
:: MDC_ATTR_RACK_NUMBER – String - 1…X  -- RACK MDS
:: MDC_ATTR_RACK_CAPACITY – numeric - 1..X  -- RACK MDS
::  
:: MDC_RACK_DETAILS_TERM – array -  (index, number, capacity)  i.e. (Left, 2, NOS)
::  
:: MDC_ATTR_PUMP_RACK_POSITION – numeric - 1..X  PUMP VMD
::  
:: Or
:: MDC_PUMPRACK_DETAILS_TERM – array -  (index, number, capacity, slot)  i.e. (Left, 2, NOS, 3)
 
:: Could have Two REFIDS – maximal position, actual position
 




'''Decisions/Issues:'''
'''Decisions/Issues:'''


 
:Picture for different options  -Tom/Al will diagram how theirs works, others can provide thiers prior to next meeting for discussion.
::1  vs  1-2-3-4
::2
::3
::4
'''Action(s):'''
'''Action(s):'''


 
:CP to document which terms are under the MDS if it is a Rack and which terms are under the pump's VMD.  Provide a picture.


|-
|-

Revision as of 14:07, 11 January 2021

(Infusion Pump Main Page)


Meeting Purpose

IHE PCD Infusion Pump Working Group discussions.

WebEx Information

Topic: IHE PCD Infusion Pump WG

Date: Monday, January 11, 2021

Time: 12:00, Eastern Time (GMT -05:00, New York)

Duration: 60 Minutes


Note: Specific web & phone information will be provided via e-mail to group members.

Contact Kurt Elliason for more information.

Proposed Agenda

1. Review today's Agenda
2. Review 2020-12-14 Pump WebEx Session
3. Discussion of FHIR based approach to pump programming - Brian W
4. CPs for new Rack terms
CP for position in Pillar/Tower-Rack-Slot
CP to document which terms are under the MDS if it is a Rack and which terms are under the pump's VMD.
5. Review PCD Device Infusion Pump Action Items
6. New Business / Next Meetings

Attachments / Materials

  • <add attachments links here>

Discussion Notes

Chair/Host: Kurt Elliason (Smiths Medical)
Participants: Al Engelbert (BBraun), Andrea Robertson (Smiths), Brian Witkowski (BBraun), Jeff Rinda (Interoperability Solutions), Marufur Rahmen (ICU), Paul Schluter (CMI), Shantanu Chawla (BD), Tom Kowalczyk (BBraun)


NOTE: Action Item Review updates have been posted directly to the Infusion Pump Action Items wiki page


Item Topic Discussion
1 Agenda & Discussion Notes Review
- Chair
Status/Discussion:


Decisions/Issues:


Action(s):

2 Discussion of FHIR based approach to pump programming
- Brian W.
Status/Discussion:
Deferred to future meeting

Decisions/Issues:


Action(s):


3 Rack CPs
- tbd
Status/Discussion:
CP for position in Pillar/Tower-Rack-Slot
BBRaun reports Pillar number and slots in pillar
Discussed option to create specific OBX’s for each. Eg.
MDC_ATTR_RACK_INDEX – String - Left, Right, Top, Bottom
MDC_ATTR_RACK_POSITION – String - Left, Right, Top, Bottom, Center -- RACK MDS
MDC_ATTR_RACK_NUMBER – String - 1…X -- RACK MDS
MDC_ATTR_RACK_CAPACITY – numeric - 1..X -- RACK MDS
 
MDC_RACK_DETAILS_TERM – array - (index, number, capacity) i.e. (Left, 2, NOS)
 
MDC_ATTR_PUMP_RACK_POSITION – numeric - 1..X PUMP VMD
 
Or
MDC_PUMPRACK_DETAILS_TERM – array - (index, number, capacity, slot) i.e. (Left, 2, NOS, 3)

 

Could have Two REFIDS – maximal position, actual position

 


Decisions/Issues:

Picture for different options -Tom/Al will diagram how theirs works, others can provide thiers prior to next meeting for discussion.
1 vs 1-2-3-4
2
3
4

Action(s):

CP to document which terms are under the MDS if it is a Rack and which terms are under the pump's VMD. Provide a picture.
4 Next Meeting
- Chair
Status/Discussion:

Decisions/Issues:

  • Topics will include ...

Action(s):


Next Meeting

NOTE: Next Meeting will be held during the regularly scheduled time: 11:00 (Eastern) on January 25 (60 minutes)


(Reviewed & approved by PCD Infusion Pump WG on <TBD>


PCD Home