The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.
 
The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.
 
|Example=
 
|Example=
<pre>
 
<ClinicalDocument
 
  ...
 
  <component typeCode="COMP">
 
    <structuredBody classCode="DOCBODY" moodCode="EVN">
 
          ...
 
          <entry typeCode="DRIV">
 
            <templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3.1"/>
 
            <act classCode="ACT" moodCode="EVN">
 
              ...
 
              <entryRelationship typeCode="COMP">
 
                <observation classCode="COND" moodCode="EVN">
 
                  <templateId root="1.3.6.1.4.1.19376.1.3.1.1.1"/>
 
                  <code code="170516003" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT"
 
                        displayName="Notification of Disease">
 
                    <qualifier>
 
                      <name code="246087005" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT"
 
                            displayName="Source of Specimen"/>
 
                      <value code="116154003" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT"
 
                            displayName="Patient"/>
 
                    </qualifier>
 
                  </code>
 
                  <value xsi:type="CE" code="27268008" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT"
 
                                      displayName="Salmonella">
 
                    <translation code="L-17100" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED"/>
 
                  </value>
 
                </observation>
 
              </entryRelationship>
 
</pre>
 
 
 
 
<pre>
 
<pre>
 
<ClinicalDocument>
 
<ClinicalDocument>
Line 106: Line 75:
 
   </component>
 
   </component>
 
</ClinicalDocument>
 
</ClinicalDocument>
 
 
</pre>
 
</pre>
 
}}
 
}}

Revision as of 12:27, 13 June 2008

Return to: PCC TF-1/PHLAB/XDSLAB Harmonization
Return to: Laboratory Data Processing Entry

Development Only

The PCC Wiki Content is used only for development of IHE PCC Content. The Normative content of the PCC Technical Framework and the current supplements can be found at http://www.ihe.net/Technical_Framework/index.cfm#PCC

Trial.gif Notifiable Condition 1.3.6.1.4.1.19376.1.3.1.1.1

Notifiable Condition, when present, SHALL be recorded as an observation in an entryRelationship under the 'Specimen Act' of a Laboratory data processing entry (1.3.6.1.4.1.19376.1.3.1) as demonstrated in the figure below. Notifiable Condition SHALL be present when dictated by local public health requirements.

The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.


Uses

See Templates using Notifiable Condition

Specification
Notifiable Condition Example
<ClinicalDocument>
  ...
  <component typeCode="COMP">
    <structuredBody classCode="DOCBODY" moodCode="EVN">
      <component typeCode="COMP">
        <section classCode="DOCSECT">
          <templateId extension="??" root="1.3.6.1.4.1.19376.1.3.3.2.1"/>
          <code code="18725-2" codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC" displayName="MICROBIOLOGY STUDIES"/>
          <entry typeCode="DRIV">
            <templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3.1"/>
            <act classCode="ACT" moodCode="EVN">
              <entryRelationship typeCode="COMP">
                <organizer classCode="CLUSTER" moodCode="EVN">
                  <component>
                    <observation classCode="COND" moodCode="EVN">
                      <templateId root="1.3.6.1.4.1.19376.1.3.1.1.1"/>
                      <code code="170516003" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT" 
                            displayName="Notification of Disease">
                        <qualifier>
                          <name code="246087005" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT" 
                                displayName="Source of Specimen"/>
                          <value code="116154003" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT" 
                                 displayName="Patient"/>
                        </qualifier>
                      </code>
                      <value xsi:type="CE" code="27268008" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT" 
                             displayName="Salmonella">
                        <translation code="L-17100" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED"/>
                      </value>
                    </observation>
                  </component>
                  <component>
                    <observation classCode="CASE" moodCode="EVN">
                      <templateId root="1.3.6.1.4.1.19376.1.3.1.1.2"/>
                      ...
                    </observation>
                  </component>
                  <component>
                    <observation classCode="OUTB" moodCode="EVN">
                      <templateId root="1.3.6.1.4.1.19376.1.3.1.1.3"/>
                      ...
                    </observation>
                  </component>
                </organizer>
              </entryRelationship>
            </act>
          </entry>
        </section>
      </component>
      <component>
        <section>
          <templateId extension="??" root="1.3.6.1.4.1.19376.1.3.3.2.1"/>
          <code code="18725-2" codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC" displayName="MICROBIOLOGY STUDIES"/>
          <title>Laboratory Microbiology Results</title>
          <text/>
          <entry typeCode="DRIV">
            <templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3"/>
            <act classCode="ACT" moodCode="EVN">
              ...
            </act>
          </entry>
        </section>
      </component>
    </structuredBody>
  </component>
</ClinicalDocument>


<observation classCode="COND" moodCode="EVN">

The Notifiable Condition Observation shall be recorded as shown above, classCode "COND" and moodCode "EVN".

<templateId root="1.3.6.1.4.1.19376.1.3.1.1.1"/>

The <templateId> element identifies this <observation> as the Notifiable Condition. The templateId shall be recorded as shown above, root="1.3.6.1.4.1.19376.1.3.1.1.1".

The Notifiable Condition Observation shall contain a unique public health code.

<qualifier/>

The Notifiable Condition Observation qualifier shall identify the source of the notifiable condition. Eg, Patient, Food, Animal.

<value/>

The Notifiable Condition Observation value shall specify the specific public health notifiable condition. Eg, Salmonella, Rabies, Bacillus anthracis.