Difference between revisions of "1.3.6.1.4.1.19376.1.3.1.1.1"

From IHE Wiki
Jump to navigation Jump to search
Line 2: Line 2:
  
 
{{HL7V3|Notifiable Condition|1.3.6.1.4.1.19376.1.3.1.1|Trial|
 
{{HL7V3|Notifiable Condition|1.3.6.1.4.1.19376.1.3.1.1|Trial|
Notifiable Condition shall be recorded an observation in an entryRelationship under the Laboratory data processing entry ([[1.3.6.1.4.1.19376.1.3.1]]) as demonstrated in the figure below.   
+
Notifiable Condition, when present, shall be recorded an observation in an entryRelationship under the Laboratory data processing entry ([[1.3.6.1.4.1.19376.1.3.1]]) as demonstrated in the figure below.   
  
 
This module is out of the PHLab Specification. This module does not change requirements stated in that specification but is structured as a module to ensure consistent content representation and re-usability. Regarding the XDS-Lab Current Specification, this is an outstanding issue as it is not addressed today.  
 
This module is out of the PHLab Specification. This module does not change requirements stated in that specification but is structured as a module to ensure consistent content representation and re-usability. Regarding the XDS-Lab Current Specification, this is an outstanding issue as it is not addressed today.  
Line 40: Line 40:
  
 
=====<templateId root='1.3.6.1.4.1.19376.1.3.1.1'/>=====
 
=====<templateId root='1.3.6.1.4.1.19376.1.3.1.1'/>=====
The <templateId> element identifies this <participant> as an intended recipient.  The templateId must have root='1.3.6.1.4.1.19376.1.3.1.1'.
+
The <templateId> element identifies this <observation> as the Notifiable Condition.  The templateId shall have root='1.3.6.1.4.1.19376.1.3.1.1'.

Revision as of 17:47, 8 May 2008

Return to: PCC TF-1/PHLAB/XDSLAB Harmonization

Development Only

The PCC Wiki Content is used only for development of IHE PCC Content. The Normative content of the PCC Technical Framework and the current supplements can be found at http://www.ihe.net/Technical_Framework/index.cfm#PCC

Trial.gif Notifiable Condition 1.3.6.1.4.1.19376.1.3.1.1

Notifiable Condition, when present, shall be recorded an observation in an entryRelationship under the Laboratory data processing entry (1.3.6.1.4.1.19376.1.3.1) as demonstrated in the figure below.

This module is out of the PHLab Specification. This module does not change requirements stated in that specification but is structured as a module to ensure consistent content representation and re-usability. Regarding the XDS-Lab Current Specification, this is an outstanding issue as it is not addressed today.

The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.


Uses

See Templates using Notifiable Condition

Specification
Notifiable Condition Example
<ClinicalDocument
  ...
  <component typeCode="COMP">
    <structuredBody classCode="DOCBODY" moodCode="EVN">
      <component typeCode="COMP">
        <section classCode="DOCSECT">
          ...
          <entry typeCode="DRIV">
            <templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3.1"/>
            <act classCode="ACT" moodCode="EVN">
              ...
              <entryRelationship typeCode="COMP">
                <observation classCode="OBS" moodCode="EVN">
                  <templateId root="1.3.6.1.4.1.19376.1.3.1.1"/>
                  <code code="170516003" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT" 
                        displayName="Notification of Disease">
                    <qualifier>
                      <name code="246087005" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT" 
                            displayName="Source of Specimen"/>
                      <value code="116154003" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT" 
                             displayName="Patient"/>
                    </qualifier>
                  </code>
                  <value xsi:type="CE" code="27268008" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT" 
                                       displayName="Salmonella">
                    <translation code="L-17100" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED"/>
                  </value>


<templateId root='1.3.6.1.4.1.19376.1.3.1.1'/>

The <templateId> element identifies this <observation> as the Notifiable Condition. The templateId shall have root='1.3.6.1.4.1.19376.1.3.1.1'.