Difference between revisions of "1.3.6.1.4.1.19376.1.3.1.1"

From IHE Wiki
Jump to navigation Jump to search
(1.3.6.1.4.1.19376.1.3.1.1 moved to 1.3.6.1.4.1.19376.1.3.1.1.1: re-ordering template ids)
 
Line 1: Line 1:
#REDIRECT [[1.3.6.1.4.1.19376.1.3.1.1.1]]
+
Return to: [[PCC TF-1/PHLAB/XDSLAB Harmonization]]
 +
<br>
 +
Return to: [[1.3.6.1.4.1.19376.1.3.1|Laboratory Data Processing Entry]]
 +
 
 +
{{HL7V3|Notification Organizer|1.3.6.1.4.1.19376.1.3.1.1|Trial|
 +
DESCRIPTION
 +
 
 +
 
 +
The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.
 +
|Example=
 +
<pre>
 +
<ClinicalDocument>
 +
  ...
 +
  <component typeCode="COMP">
 +
    <structuredBody classCode="DOCBODY" moodCode="EVN">
 +
      <component typeCode="COMP">
 +
        <section classCode="DOCSECT">
 +
          <templateId extension="??" root="1.3.6.1.4.1.19376.1.3.3.2.1"/>
 +
          <code code="18725-2" codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC" displayName="MICROBIOLOGY STUDIES"/>
 +
          <text/>
 +
          <entry typeCode="DRIV">
 +
            <templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3.1"/>
 +
            <act classCode="ACT" moodCode="EVN">
 +
              <entryRelationship typeCode="COMP">
 +
                <organizer classCode="CLUSTER" moodCode="EVN">
 +
                  <component>
 +
                    <observation classCode="COND" moodCode="EVN">
 +
                      <templateId root="1.3.6.1.4.1.19376.1.3.1.1.1"/>
 +
                      <code code="170516003" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT"
 +
                            displayName="Notification of Disease">
 +
                        <qualifier>
 +
                          <name code="246087005" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT"
 +
                                displayName="Source of Specimen"/>
 +
                          <value code="116154003" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT"
 +
                                displayName="Patient"/>
 +
                        </qualifier>
 +
                      </code>
 +
                      <value xsi:type="CE" code="27268008" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT"
 +
                            displayName="Salmonella"/>
 +
                    </observation>
 +
                  </component>
 +
                  <component>
 +
                    <observation classCode="CASE" moodCode="EVN">
 +
                      <templateId root="1.3.6.1.4.1.19376.1.3.1.1.2"/>
 +
                      ...
 +
                    </observation>
 +
                  </component>
 +
                  <component>
 +
                    <observation classCode="OUTB" moodCode="EVN">
 +
                      <templateId root="1.3.6.1.4.1.19376.1.3.1.1.3"/>
 +
                      ...
 +
                    </observation>
 +
                  </component>
 +
                </organizer>
 +
              </entryRelationship>
 +
            </act>
 +
          </entry>
 +
        </section>
 +
      </component>
 +
      <component>
 +
        <section>
 +
          <templateId extension="??" root="1.3.6.1.4.1.19376.1.3.3.2.1"/>
 +
          <code code="18725-2" codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC" displayName="MICROBIOLOGY STUDIES"/>
 +
          <title>Laboratory Microbiology Results</title>
 +
          <text/>
 +
          <entry typeCode="DRIV">
 +
            <templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3"/>
 +
            <act classCode="ACT" moodCode="EVN">
 +
              ...
 +
            </act>
 +
          </entry>
 +
        </section>
 +
      </component>
 +
    </structuredBody>
 +
  </component>
 +
</ClinicalDocument>
 +
</pre>
 +
}}
 +
 
 +
=====constraints====

Revision as of 15:52, 13 June 2008

Return to: PCC TF-1/PHLAB/XDSLAB Harmonization
Return to: Laboratory Data Processing Entry

Development Only

The PCC Wiki Content is used only for development of IHE PCC Content. The Normative content of the PCC Technical Framework and the current supplements can be found at http://www.ihe.net/Technical_Framework/index.cfm#PCC

Trial.gif Notification Organizer 1.3.6.1.4.1.19376.1.3.1.1

DESCRIPTION


The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.


Uses

See Templates using Notification Organizer

Specification
Notification Organizer Example
<ClinicalDocument>
  ...
  <component typeCode="COMP">
    <structuredBody classCode="DOCBODY" moodCode="EVN">
      <component typeCode="COMP">
        <section classCode="DOCSECT">
          <templateId extension="??" root="1.3.6.1.4.1.19376.1.3.3.2.1"/>
          <code code="18725-2" codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC" displayName="MICROBIOLOGY STUDIES"/>
          <text/>
          <entry typeCode="DRIV">
            <templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3.1"/>
            <act classCode="ACT" moodCode="EVN">
              <entryRelationship typeCode="COMP">
                <organizer classCode="CLUSTER" moodCode="EVN">
                  <component>
                    <observation classCode="COND" moodCode="EVN">
                      <templateId root="1.3.6.1.4.1.19376.1.3.1.1.1"/>
                      <code code="170516003" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT" 
                            displayName="Notification of Disease">
                        <qualifier>
                          <name code="246087005" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT" 
                                displayName="Source of Specimen"/>
                          <value code="116154003" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT" 
                                 displayName="Patient"/>
                        </qualifier>
                      </code>
                      <value xsi:type="CE" code="27268008" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT" 
                             displayName="Salmonella"/>
                    </observation>
                  </component>
                  <component>
                    <observation classCode="CASE" moodCode="EVN">
                      <templateId root="1.3.6.1.4.1.19376.1.3.1.1.2"/>
                      ...
                    </observation>
                  </component>
                  <component>
                    <observation classCode="OUTB" moodCode="EVN">
                      <templateId root="1.3.6.1.4.1.19376.1.3.1.1.3"/>
                      ...
                    </observation>
                  </component>
                </organizer>
              </entryRelationship>
            </act>
          </entry>
        </section>
      </component>
      <component>
        <section>
          <templateId extension="??" root="1.3.6.1.4.1.19376.1.3.3.2.1"/>
          <code code="18725-2" codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC" displayName="MICROBIOLOGY STUDIES"/>
          <title>Laboratory Microbiology Results</title>
          <text/>
          <entry typeCode="DRIV">
            <templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3"/>
            <act classCode="ACT" moodCode="EVN">
              ...
            </act>
          </entry>
        </section>
      </component>
    </structuredBody>
  </component>
</ClinicalDocument>


=constraints