Proposed Work Item: Laboratory Specimen Handoff (LSH)

Proposal Editor: John Hopson, Abbott Laboratories
Work Item Editor: John Hopson
Date: 05/22/2015, last updated 05/22/2015
Version: 1.0 (draft)
Domain: Clinical Laboratory
Status: LSH Update Proposal Spring 2015.

Summary

Passing of specimens between Laboratory Automation Systems (LAS) and Specimen Processing Devices (SPD) is an integral part of clinical laboratory operation. In the absence of any industry guidance, such handoffs are currently defined on an ad hoc basis. Implementers naturally turn to predecessor products for guidance. This approach causes similar interfaces to be created within each organization, even though such interfaces share features with products from a variety of vendors.

There clearly exists a need for fully specified interface protocols to reduce the time and costs associated with managing sample handoff in clinical laboratories. The IHE-LAB Committee is the appropriate entity to create and promote such solutions. Prior work by the Committee on the LDA profile is evidence of that need.

This proposed profile will enable LAS and SPD to implement specimen handoff using standardized protocols, reducing the new product design burden for all parties.


The Problem

Current LAS and SPD vendors have little guidance on how to implement specimen handoff interfaces between their equipment. HL7 and CLSI AUTO3-A provide some direction, but do not provide specific guidance for individual handoff workflows.


Use Cases

There are multiple use cases for sample handoff in the laboratory. The most common is the single-sample, point-in-space presentation use case. The second most common is the single-sample

A third common use case is the passing of a rack of samples between laboratory automation and

This proposal will be implemented in at least three phases, in order of commonality.

  1. Single-Sample Point-in-Space Presentation Use Case

Automation notifies the IVD analyzer that a sample is en route to the IVD analyzer. The IVD analyzer prepares for sample arrival. Upon arrival, automation presents the sample for aspiration. IVD analyzer aspirates from the sample and notifies automation when sampling is complete. Automation removes the sample from the aspiration position.

Standards and Systems

Existing systems that could be involved in the solution.

  1. IVD analyzer
  2. Laboratory automation sample transport track system

Relevant standards upon which the solution might be based.

  1. HL7
  2. CLSI AUTO5-A (HL7 Chapter 13


Technical Approach Overview

Actors

The proposed LDA actors are shown below.

  1. Order Filler - Receives the laboratory work for each patient
  2. Analyzer/Automation Manager - Manages analytical work for the instrument based on the Work Order. Produces AWOS’s. Also, manages specimen (automation) work for pre/post processing. Produces SWOS’s
  3. Analyzer - Instrument that automates IVD testing
  4. Track - Manages specimen container transport and handoff
  5. Pre/Post Processor - Device that automates specimen preparation