Reporting Whitepaper - Section 5
| Artifact | Encoding | Transaction | Transport | Input/Output | |
|---|---|---|---|---|---|
| Patient Account | HL7 PV1 | Patient Update | (HL7 Msg) | {D1-Push} | |
| Order | HL7 ORM | Placer Order Management | (HL7 Msg) | {D2-Push} | |
| Worklist | DICOM MWL IOD | Modality Worklist Provided | DICOM MWM C-Find | {W1-Pull} | |
| DICOM UPS IOD | (Query Worklist) | DICOM UPS C-Find | {W2-Pull}, {W4-Pull} | ||
| (Push Workitem) | DICOM UPS N-Create | {W2-Push} | |||
| Images| | DICOM Image IODs | Images Stored | DICOM C-Store | {D3-Push}, {D7-Push} | |
| Retrieve Images | DICOM C-Store | {D3-Pull} | |||
| Performed Proc. | DICOM MPPS IOD | Images Stored | DICOM C-Store | {D4-Push} | |
| Radiation Dose | DICOM SR Dose IOD | (Dose Stored) | DICOM C-Store | {D5-Push} | |
| Procedure Log | DICOM SR PLog IOD | (Procedure Log Stored) | DICOM C-Store | {D6-Push} | |
| Dictation Audio | ??? | (Audio Stored) | ??? | {D6-Push} | |
| Radiology Report| | HL7 CDA | (D-Report Stored) | DICOM C-Store | ||
| (H-Report Stored) | (HL7-Msg) |
Performed Proc. Details HL7 DFT
History/Allergies/Problems/Meds CDA-MS
Lab Results
Pathology Results
Patient History Sheet
Tech Interview Sheet
Proto Report CDA
Draft Report CDA
Final Report CDA
Bill X12
<Material from Section 3 to go in Section 5>
- Investigate CDA as an authoring and distribution format for diagnostic reports
- Two gaps are:
- the lack of CDA report templates for a broad set of Radiology reports
- the lack of deployed implementations using CDA