1.3.6.1.4.1.19376.1.5.3.1.1.11.2
Development Only
The PCC Wiki Content is used only for development of IHE PCC Content. The Normative content of the PCC Technical Framework and the current supplements can be found at http://www.ihe.net/Technical_Framework/index.cfm#PCC
Antepartum Summary Form C, F & G Specification 1.3.6.1.4.1.19376.1.5.3.1.1.11.2
Specification
| Data Element Name | Opt | Template ID |
|---|---|---|
| Allergies Must include observation of Latex Allergy |
R | |
| Advance Directives Must include observation of blood transfusion acceptable? |
R | |
| Plan of Care Must include observation stating if an anesthesia consult is planned |
R | |
| Medications | R | |
| Problems | R |
Conformance
CDA Release 2.0 documents that conform to the requirements of this content module shall indicate their conformance by the inclusion of the appropriate <templateId> elements in the header of the document. This is shown in the sample document below.
<ClinicalDocument xmlns='urn:hl7-org:v3'> <typeId extension="POCD_HD000040" root="2.16.840.1.113883.1.3"/> <templateId root='1.3.6.1.4.1.19376.1.5.3.1.1.11.2'/> <id root=' ' extension=' '/> <code code=' ' displayName=' ' codeSystem='2.16.840.1.113883.6.1' codeSystemName='LOINC'/> <title>Antepartum Summary Form C, F & G</title> <effectiveTime value='20260407012005'/> <confidentialityCode code='N' displayName='Normal' codeSystem='2.16.840.1.113883.5.25' codeSystemName='Confidentiality' /> <languageCode code='en-US'/> : <component><structuredBody> </structuredBody></component> </ClinicalDocument> |
<!-- Verify the document type code -->
<assert test='cda:code[@code = "{{{LOINC}}}"]'>
Error: The document type code of a Antepartum Summary Form C, F & G must be {{{LOINC}}}
</assert>
<assert test='cda:code[@codeSystem = "2.16.840.1.113883.6.1"]'>
Error: The document type code must come from the LOINC code
system (2.16.840.1.113883.6.1).
</assert>