1.3.6.1.4.1.19376.1.3.1.5
Return to: PCC TF-1/PHLAB/XDSLAB Harmonization
Development Only
The PCC Wiki Content is used only for development of IHE PCC Content. The Normative content of the PCC Technical Framework and the current supplements can be found at http://www.ihe.net/Technical_Framework/index.cfm#PCC
Laboratory Organizer - Isolate Organizer 1.3.6.1.4.1.19376.1.3.1.5
Laboratory Organizer, when present, shall be recorded an organizer in an entryRelationship under the Laboratory data processing entry (1.3.6.1.4.1.19376.1.3.1) as demonstrated in the figure below. Use of a laboratory organizer is restricted to the grouping of a test battery or a cluster of related laboratory tests.
This module is out of the XDS-Lab Specification. This module does not change requirements stated in that specification but is structured as a module to ensure consistent content representation and re-usability.
The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.
Uses
See Templates using Laboratory Organizer - Isolate Organizer
Specification
<ClinicalDocument
...
<component typeCode="COMP">
<structuredBody classCode="DOCBODY" moodCode="EVN">
<component typeCode="COMP">
<section classCode="DOCSECT">
...
<entry typeCode="DRIV">
<templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3.1"/>
<act classCode="ACT" moodCode="EVN">
...
<entryRelationship typeCode="COMP">
<organizer classCode="CLUSTER" moodCode="EVN">
<templateId root="1.3.6.1.4.1.19376.1.3.1.5"/>
<statusCode code="completed"/>
<effectiveTime value="20071108000000.0000-0500"/>
<specimen>
<specimenRole classCode="ISLT">
<specimenPlayingEntity>
|
<templateId root='1.3.6.1.4.1.19376.1.3.1.5'/>
The <templateId> element identifies this <organizer> as the Laboratory Organizer - Isolate Organizer. The templateId shall have root='1.3.6.1.4.1.19376.1.3.1.5'.