Talk:1.3.6.1.4.1.19376.1.5.3.1.1.13.1.4

From IHE Wiki
Revision as of 17:19, 6 December 2007 by McCaffrey (talk | contribs) (New page: {{Fixme | In the table listing LOINC codes, "List of Surgeries" is shown as having a LOINC code of "10167-5 HISTORY OF SURGICAL PROCEDURES". In the table listing template IDs, "List of S...)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

This text needs to be fixed-->>

In the table listing LOINC codes, "List of Surgeries" is shown as having a LOINC code of "10167-5 HISTORY OF SURGICAL PROCEDURES".

In the table listing template IDs, "List of Surgeries" is shown as having a template ID of "1.3.6.1.4.1.19376.1.5.3.1.3.11".

However, on the page describing template ID 1.3.6.1.4.1.19376.1.5.3.1.3.11, the requisite LOINC code is given as: 47519-4 HISTORY OF PROCEDURES.

There is a conflict between two differing LOINC codes.

The CCD parent of 1.3.6.1.4.1.19376.1.5.3.1.3.11 gives us a clue as to which LOINC code was probably intended. The CCD parent template ID is 2.16.840.1.113883.10.20.1.12. According to CCD 3.14 Procedures (pg 54): "The template identifier for the procedures section is 2.16.840.1.113883.10.20.1.12." And by CONF-424 we see: 'The value for "Section / code" SHALL be "47519-4" "History of procedures" 2.16.840.1.113883.6.1 LOINC STATIC.'

Therefore the solution to this conflict would be to choose the LOINC code specified by CCD and change the LOINC in the table for List of Surgeries to 47519-4.

<<--