Aps vol2 content-modules cda-r2-content-modules
CDA Release 2 Content Modules
CDA Document Content Modules
Development Only
The PCC Wiki Content is used only for development of IHE PCC Content. The Normative content of the PCC Technical Framework and the current supplements can be found at http://www.ihe.net/Technical_Framework/index.cfm#PCC
Antepartum Summary Form C, F & G Specification 1.3.6.1.4.1.19376.1.5.3.1.1.11.2
Specification
| Data Element Name | Opt | Template ID |
|---|---|---|
| Allergies Must include observation of Latex Allergy |
R | |
| Advance Directives Must include observation of blood transfusion acceptable? |
R | |
| Plan of Care Must include observation stating if an anesthesia consult is planned |
R | |
| Medications | R | |
| Problems | R |
Conformance
CDA Release 2.0 documents that conform to the requirements of this content module shall indicate their conformance by the inclusion of the appropriate <templateId> elements in the header of the document. This is shown in the sample document below.
<ClinicalDocument xmlns='urn:hl7-org:v3'> <typeId extension="POCD_HD000040" root="2.16.840.1.113883.1.3"/> <templateId root='1.3.6.1.4.1.19376.1.5.3.1.1.11.2'/> <id root=' ' extension=' '/> <code code=' ' displayName=' ' codeSystem='2.16.840.1.113883.6.1' codeSystemName='LOINC'/> <title>Antepartum Summary Form C, F & G</title> <effectiveTime value='20260408012005'/> <confidentialityCode code='N' displayName='Normal' codeSystem='2.16.840.1.113883.5.25' codeSystemName='Confidentiality' /> <languageCode code='en-US'/> : <component><structuredBody> </structuredBody></component> </ClinicalDocument> |
<!-- Verify the document type code -->
<assert test='cda:code[@code = "{{{LOINC}}}"]'>
Error: The document type code of a Antepartum Summary Form C, F & G must be {{{LOINC}}}
</assert>
<assert test='cda:code[@codeSystem = "2.16.840.1.113883.6.1"]'>
Error: The document type code must come from the LOINC code
system (2.16.840.1.113883.6.1).
</assert>
Development Only
The PCC Wiki Content is used only for development of IHE PCC Content. The Normative content of the PCC Technical Framework and the current supplements can be found at http://www.ihe.net/Technical_Framework/index.cfm#PCC
docname2 Specification did2
desc2
Specification
| Data Element Name | Opt | Template ID |
|---|---|---|
| sect1 | R | sid1 |
Conformance
CDA Release 2.0 documents that conform to the requirements of this content module shall indicate their conformance by the inclusion of the appropriate <templateId> elements in the header of the document. This is shown in the sample document below.
<ClinicalDocument xmlns='urn:hl7-org:v3'> <typeId extension="POCD_HD000040" root="2.16.840.1.113883.1.3"/> <templateId root='did2'/> <id root=' ' extension=' '/> <code code=' ' displayName=' ' codeSystem='2.16.840.1.113883.6.1' codeSystemName='LOINC'/> <title>docname2</title> <effectiveTime value='20260408012005'/> <confidentialityCode code='N' displayName='Normal' codeSystem='2.16.840.1.113883.5.25' codeSystemName='Confidentiality' /> <languageCode code='en-US'/> : <component><structuredBody> </structuredBody></component> </ClinicalDocument> |
<!-- Verify the document type code -->
<assert test='cda:code[@code = "{{{LOINC}}}"]'>
Error: The document type code of a docname2 must be {{{LOINC}}}
</assert>
<assert test='cda:code[@codeSystem = "2.16.840.1.113883.6.1"]'>
Error: The document type code must come from the LOINC code
system (2.16.840.1.113883.6.1).
</assert>
CDA Header Content Modules
CDA Section Content Modules
Development Only
The PCC Wiki Content is used only for development of IHE PCC Content. The Normative content of the PCC Technical Framework and the current supplements can be found at https://www.ihe.net/resources/technical_frameworks/#pcc
Estimated Due Dates Section
| Template ID | 1.2.6.1.4.1.19376.1.5.3.1.1.11.2.1 | |
|---|---|---|
| General Description | This section houses the physicians best estimate of the patients due date. This is generally done both on an initial evaluation, and later confirmed at 18-20 weeks. The date is supported by evidence such as the patients history of last menstral period, a physical examination, or ultrasound measurements. If an gestational age based on ultrasound is present, it is generally considered the most accurate measurement and so that date would be chosen. | |
| LOINC Codes | Opt | Description |
| (LOINC-requested) | R | EntryName1 |
| Entries | Opt | Description |
| 1.2.6.1.4.1.19376.1.5.3.1.1.11.2.1 | R | entN if one observation is present, then it is to be interpreted as the initial EDD. If observations dates indicate the EDD is within 20 weeks, the most recent observation will also be interpreted as the 18-20 week update. |
<component>
<section>
<templateId root='1.2.6.1.4.1.19376.1.5.3.1.1.11.2.1'/>
<id root=' ' extension=' '/>
<code code=' ' displayName=' '
codeSystem='2.16.840.1.113883.6.1' codeSystemName='LOINC'/>
<text>
Text as described above
</text>
|
Uses
See Templates using the Estimated Due Dates Section