1.3.6.1.4.1.19376.1.3.1.6
Revision as of 18:47, 8 May 2008 by Seknoop (talk | contribs) (New page: Return to: PCC TF-1/PHLAB/XDSLAB Harmonization {{HL7V3|Laboratory Observation |1.3.6.1.4.1.19376.1.3.1.6|Trial| Notifiable Condition, when present, shall be recorded an observation in...)
Return to: PCC TF-1/PHLAB/XDSLAB Harmonization
Development Only
The PCC Wiki Content is used only for development of IHE PCC Content. The Normative content of the PCC Technical Framework and the current supplements can be found at http://www.ihe.net/Technical_Framework/index.cfm#PCC
Laboratory Observation 1.3.6.1.4.1.19376.1.3.1.6
Example Description
Uses
See Templates using Laboratory Observation
Specification
<ClinicalDocument ... <component typeCode="COMP"> <structuredBody classCode="DOCBODY" moodCode="EVN"> <component typeCode="COMP"> <section classCode="DOCSECT"> ... <entry typeCode="DRIV"> <templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3.1"/> <act classCode="ACT" moodCode="EVN"> ... <entryRelationship typeCode="COMP"> <observation classCode="OBS" moodCode="EVN"> <templateId root="1.3.6.1.4.1.19376.1.3.1.6"/> <code code="23749-5" codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC" displayName="Lead Measurement, Quantitative"> <originalText><reference value="pbTest"/></originalText> </code> <statusCode code="completed"/> <effectiveTime value="20071108000000.0000-0500"/> <value xsi:type="PQ" unit="mg/dL" value="7.4"/> <interpretationCode code="H" codeSystem="2.16.840.1.113883.5.83"/> |
<templateId root='1.3.6.1.4.1.19376.1.3.1.6'/>
The <templateId> element identifies this <observation> as a Laboratory Result. The templateId shall have root='1.3.6.1.4.1.19376.1.3.1.6'.