[[Reporting Whitepaper| <Return to the main Reporting Whitepaper page>]]
{| style="width:100%" border="1" cellpadding="3"
{| style="width:100%" border="1" cellpadding="3"
! Artifact
! Artifact
Line 6: Line 9:
! Input/Output
! Input/Output
|-
|-
| Patient Account || HL7 PV1        || Patient Update            || (HL7 Msg)    || {D1-Push} ||  
| Patient Account || HL7 PV1        || Patient Update            || (HL7 Msg)    || {P1-Push} ||  
|-
|-
| Order          || HL7 ORM        || Placer Order Management    || (HL7 Msg)    || {D2-Push} ||
| Order          || HL7 ORM        || Placer Order Management    || (HL7 Msg)    || {O1-Push} ||
|-
|-
|rowspan="3"|Worklist
|rowspan="3"|Worklist
Line 40: Line 43:
|                                        ''(H-Report Stored)''      || (HL7-Msg)    ||            ||
|                                        ''(H-Report Stored)''      || (HL7-Msg)    ||            ||
|-
|-
| History/Allergies/ <br>Problems/Meds || HL7 CDA-MS || ??? || ??? || {D20-Pull?}  ||
| History/Allergies/ <br>Problems/Meds || HL7 CDA-MS || ???         || ???           || {P2-Pull?}  ||
|-
| Staff Schedule      || HL7 ???      || ''Out of scope?''          || ???          || {H1}        ||
|-
| Staff Certifications || HL7 ???      || <PWP>                      || ???          || {H2-Pull}  ||
|-
|-
|}
|}

Revision as of 18:47, 2 August 2007

<Return to the main Reporting Whitepaper page>


Artifact Encoding Transaction Transport Input/Output
Patient Account HL7 PV1 Patient Update (HL7 Msg) {P1-Push}
Order HL7 ORM Placer Order Management (HL7 Msg) {O1-Push}
Worklist DICOM MWL IOD Modality Worklist Provided DICOM MWM C-Find {W1-Pull}
DICOM UPS IOD (Query Worklist) DICOM UPS C-Find {W2-Pull},
{W4-Pull}
(Push Workitem) DICOM UPS N-Create {W2-Push}
Images DICOM Image IODs Images Stored DICOM C-Store {D3-Push}, {D7-Push}
Retrieve Images DICOM C-Store {D3-Pull}
Performed Proc. DICOM MPPS IOD Modality Procedure Performed DICOM N-Set {D6-Push}
DICOM UPS IOD (Procedure Performed) DICOM UPS N-Get {Dx-Pull}, {Dy-Pull}
Performed Proc. DICOM MPPS IOD Images Stored DICOM C-Store {D4-Push}
Radiation Dose DICOM SR Dose IOD (Dose Stored) DICOM C-Store {D5-Push}
Procedure Log DICOM SR PLog IOD (Procedure Log Stored) DICOM C-Store {D6-Push}
Dictation Audio ??? (Audio Stored) ??? {D6-Push}
Radiology Report
(Proto/Draft/Final)
HL7 CDA (D-Report Stored) DICOM C-Store
(H-Report Stored) (HL7-Msg)
History/Allergies/
Problems/Meds
HL7 CDA-MS ??? ??? {P2-Pull?}
Staff Schedule HL7 ??? Out of scope? ??? {H1}
Staff Certifications HL7 ??? <PWP> ??? {H2-Pull}


Performed Proc. Details using HL7 DFT?

Lab Results

Pathology Results

Patient History Sheet

Tech Interview Sheet

Bill X12


<Material from Section 3 to go in Section 5>

  • Investigate CDA as an authoring and distribution format for diagnostic reports
  • Two gaps are:
    • the lack of CDA report templates for a broad set of Radiology reports
    • the lack of deployed implementations using CDA