Reporting Whitepaper - Section 5: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
| Line 1: | Line 1: | ||
{| style="width:100%" border="1" cellpadding="3" | {| style="width:100%" border="1" cellpadding="3" | ||
! Artifact | ! Artifact | ||
| Line 12: | Line 10: | ||
| Order || HL7 ORM || Placer Order Management || (HL7 Msg) || {D2-Push} || | | Order || HL7 ORM || Placer Order Management || (HL7 Msg) || {D2-Push} || | ||
|- | |- | ||
|rowspan="3"|Worklist| | |rowspan="3"|Worklist | ||
| DICOM MWL IOD || Modality Worklist Provided || DICOM MWM C-Find || {W1-Pull} || | |||
|- | |||
|rowspan="2"| DICOM UPS IOD || ''(Query Worklist)'' || DICOM UPS C-Find || {W2-Pull}, {W4-Pull} || | |||
|- | |||
| ''(Push Workitem)'' || DICOM UPS N-Create|| {W2-Push} || | |||
|- | |||
|rowspan="2"|Images| | |||
|rowspan="2"| DICOM Image IODs || Images Stored || DICOM C-Store || {D3-Push}, {D7-Push} || | |||
|- | |- | ||
| | | Retrieve Images || DICOM C-Store || {D3-Pull} || | ||
|- | |- | ||
| | | Performed Proc. || DICOM MPPS IOD || Images Stored || DICOM C-Store || {D4-Push} || | ||
|- | |- | ||
| | | Radiation Dose || DICOM SR Dose IOD || ''(Dose Stored)'' || DICOM C-Store || {D5-Push} || | ||
|- | |- | ||
| | | Procedure Log || DICOM SR PLog IOD || ''(Procedure Log Stored)'' || DICOM C-Store || {D6-Push} || | ||
|- | |- | ||
| | | Dictation Audio || ''???'' || ''(Audio Stored)'' || ''???'' || {D6-Push} || | ||
|- | |- | ||
| | |rowspan="2"|Radiology Report| | ||
|rowspan="2"| HL7 CDA || ''(D-Report Stored)'' || DICOM C-Store || || | |||
|- | |- | ||
| | | ''(H-Report Stored)'' || (HL7-Msg) || || | ||
|- | |- | ||
|} | |} | ||
| Line 42: | Line 49: | ||
Tech Interview Sheet | Tech Interview Sheet | ||
Proto Report CDA | Proto Report CDA | ||
| Line 52: | Line 57: | ||
Bill X12 | Bill X12 | ||
<Material from Section 3 to go in Section 5> | |||
* Investigate CDA as an authoring and distribution format for diagnostic reports | * Investigate CDA as an authoring and distribution format for diagnostic reports | ||
Revision as of 23:08, 24 July 2007
| Artifact | Encoding | Transaction | Transport | Input/Output | |
|---|---|---|---|---|---|
| Patient Account | HL7 PV1 | Patient Update | (HL7 Msg) | {D1-Push} | |
| Order | HL7 ORM | Placer Order Management | (HL7 Msg) | {D2-Push} | |
| Worklist | DICOM MWL IOD | Modality Worklist Provided | DICOM MWM C-Find | {W1-Pull} | |
| DICOM UPS IOD | (Query Worklist) | DICOM UPS C-Find | {W2-Pull}, {W4-Pull} | ||
| (Push Workitem) | DICOM UPS N-Create | {W2-Push} | |||
| Images| | DICOM Image IODs | Images Stored | DICOM C-Store | {D3-Push}, {D7-Push} | |
| Retrieve Images | DICOM C-Store | {D3-Pull} | |||
| Performed Proc. | DICOM MPPS IOD | Images Stored | DICOM C-Store | {D4-Push} | |
| Radiation Dose | DICOM SR Dose IOD | (Dose Stored) | DICOM C-Store | {D5-Push} | |
| Procedure Log | DICOM SR PLog IOD | (Procedure Log Stored) | DICOM C-Store | {D6-Push} | |
| Dictation Audio | ??? | (Audio Stored) | ??? | {D6-Push} | |
| Radiology Report| | HL7 CDA | (D-Report Stored) | DICOM C-Store | ||
| (H-Report Stored) | (HL7-Msg) |
Performed Proc. Details HL7 DFT
History/Allergies/Problems/Meds CDA-MS
Lab Results
Pathology Results
Patient History Sheet
Tech Interview Sheet
Proto Report CDA
Draft Report CDA
Final Report CDA
Bill X12
<Material from Section 3 to go in Section 5>
- Investigate CDA as an authoring and distribution format for diagnostic reports
- Two gaps are:
- the lack of CDA report templates for a broad set of Radiology reports
- the lack of deployed implementations using CDA