1.3.6.1.4.1.19376.1.3.1: Difference between revisions
No edit summary |
No edit summary |
||
| Line 31: | Line 31: | ||
!Opt | !Opt | ||
!Description | !Description | ||
|- style='background-color:#ffffff;' align='center' | |||
|1.3.6.1.4.1.19376.1.3.1.1 | |||
|R2 | |||
|[[1.3.6.1.4.1.19376.1.3.1.1 | Notification Organizer]] | |||
|- style='background-color:#ffffff;' align='center' | |- style='background-color:#ffffff;' align='center' | ||
|1.3.6.1.4.1.19376.1.3.1.1.1 | |1.3.6.1.4.1.19376.1.3.1.1.1 | ||
Revision as of 17:23, 13 June 2008
Return to: PCC TF-1/PHLAB/XDSLAB Harmonization
Return to:
Laboratory Speciality Section
Development Only
The PCC Wiki Content is used only for development of IHE PCC Content. The Normative content of the PCC Technical Framework and the current supplements can be found at http://www.ihe.net/Technical_Framework/index.cfm#PCC
Lab Report Data Processing Entry 1.3.6.1.4.1.19376.1.3.1
At least one Lab Report Data Processing Entry shall be present. The Entry shall contain a single Act sub-element. This Act is hereafter referred to as the 'Specimen Act'.
For a public health lab report, there shall be exactly one Entry with one 'Specimen Act' per Section. Each 'Specimen Act' shall contain at least three EntryRelationship elements; one representing the Specimen Received Date/Time and one representing the Reportable Condition; and the third (or more) representing the laboratory test result(s).
The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.
Uses
See Templates using Lab Report Data Processing Entry
Specification
<entry typeCode="DRIV">
<templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3"/>
<act classCode="ACT" moodCode="EVN">
<statusCode code="completed"/>
... entry contents ...
</entry>
|
<templateId root='1.3.6.1.4.1.19376.1.3.1'/>
The <templateId> element identifies this <entry> as a Lab Report Data Processing Entry. The templateId shall have root='1.3.6.1.4.1.19376.1.3.1'.
<act classCode="ACT" moodCode="EVN"/>
There shall be one Act sub-element. This sub-element uses the following modules conforming to the following requirements.
| Sub-Element | Opt | Description |
|---|---|---|
| 1.3.6.1.4.1.19376.1.3.1.1 | R2 | Notification Organizer |
| 1.3.6.1.4.1.19376.1.3.1.1.1 | R2 | Notifiable Condition |
| 1.3.6.1.4.1.19376.1.3.1.1.2 | R2 | Case Identifier |
| 1.3.6.1.4.1.19376.1.3.1.1.3 | R2 | Outbreak Idenrifier |
| 1.3.6.1.4.1.19376.1.3.1.2 | R2 | Specimen Collection |
| 1.3.6.1.4.1.19376.1.3.1.3 | R2 | Specimen Received |
| tbd | R2 | Non-Human Subject |
| tbd | O | laboratory performer? (same as header??) |
| tbd | O | laboratory equipment instance |
| tbd | O | laboratory result verifier? (same as header??) |
| 1.3.6.1.4.1.19376.1.3.1.4 | R2 | Laboratory Battery Organizer |
| 1.3.6.1.4.1.19376.1.3.1.5 | R2 | Laboratory Isolate Organizer |
| 1.3.6.1.4.1.19376.1.3.1.6 | R | Laboratory Observation |
| 1.3.6.1.4.1.19376.1.5.3.1.4.2 | O | Annotation Comment (PCC) |