Line 59: Line 59:


======<code code=" " codeSystem=" " codeSystemName=" " displayName=" "/>=====
======<code code=" " codeSystem=" " codeSystemName=" " displayName=" "/>=====
The unique battery test code from an international standard, such as LOINC, MAY be present. This is different from the [1.3.6.1.4.1.19376.1.3.1.6| Laboratory Observation], where it is required.
The unique battery test code from an international standard, such as LOINC, MAY be present. This is different from the [http://wiki.ihe.net/index.php?title=1.3.6.1.4.1.19376.1.3.1.6 Laboratory Observation], where it is required.


=====<statusCode code=" "/>=====
=====<statusCode code=" "/>=====

Revision as of 14:33, 20 May 2008

Return to: PCC TF-1/PHLAB/XDSLAB Harmonization
Return to: Laboratory Data Processing Entry

Development Only

The PCC Wiki Content is used only for development of IHE PCC Content. The Normative content of the PCC Technical Framework and the current supplements can be found at http://www.ihe.net/Technical_Framework/index.cfm#PCC

Laboratory Battery Organizer 1.3.6.1.4.1.19376.1.3.1.4

Laboratory Organizer, when present, shall be recorded as an organizer in an entryRelationship under the Laboratory data processing entry (1.3.6.1.4.1.19376.1.3.1) as demonstrated in the figure below. This module is out of the XDS-Lab Specification. This module does not change requirements stated in that specification but is structured as a module to ensure consistent content representation and re-usability.

The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.

Standards
CRS HL7 Care Record Summary
Uses

See Templates using Laboratory Battery Organizer

Specification
Laboratory Battery Organizer Example
<ClinicalDocument
  ...
  <component typeCode="COMP">
    <structuredBody classCode="DOCBODY" moodCode="EVN">
      <component typeCode="COMP">
        <section classCode="DOCSECT">
          ...
          <entry typeCode="DRIV">
            <templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3.1"/>
            <act classCode="ACT" moodCode="EVN">
              ...
              <entryRelationship typeCode="COMP">
                  ...
                  <component>
                    <organizer classCode="BATTERY" moodCode="EVN">
                      <templateId root="1.3.6.1.4.1.19376.1.3.1.4"/>
                      <id root=" " extension=" "/>
                      <code code="29576-6" codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC" 
                        displayName="Microbiology Susceptibility">
                        <originalText><reference value="susceptibilityTest"/></originalText>
                      </code>
                      <statusCode code="completed"/>
                      <effectiveTime value="20071108000000.0000-0500"/>

                      <component>
                        <observation classCode="OBS" moodCode="EVN">
                          <templateId root="1.3.6.1.4.1.19376.1.3.1.6"/>
                          ...
                        </observation>
                      </component>

                      <component>
                        <observation classCode="OBS" moodCode="EVN">
                          <templateId root="1.3.6.1.4.1.19376.1.3.1.6"/>
                          ...
                        </observation>
                      </component>


<templateId root='1.3.6.1.4.1.19376.1.3.1.4'/>

The <templateId> element identifies this <organizer> as the Laboratory Battery Organizer. The templateId shall be recorded as shown above, root='1.3.6.1.4.1.19376.1.3.1.4'.

<id root=" " extension=" "/>

The observation identifier MAY be present.

=

The unique battery test code from an international standard, such as LOINC, MAY be present. This is different from the Laboratory Observation, where it is required.

<statusCode code=" "/>

The test status shall be either "completed", "aborted", or "obsolete". A status of completed means the all expected results are present. A status of aborted means at least one or more of the tests could not be performed and has no result, some results may be present. A status of obsolete means the battery has been replaced by a newer battery (following it) in this revision of the report.

NOTE: Lab TF says that "aborted" battery may have some results - I disagree. (??) NOTE: Lab TF does not specify that obsolete results have no results (in contrast to observation) - need to discuss. (??)

<effectiveTime value=" "/>

The observation's relevant clinical time (ideally specimen collection time) MAY be present.

NOTE: Lab TF does not specify that this should be the specimen collection time (in contrast to observation) - need to discuss. (??)