Difference between revisions of "1.3.6.1.4.1.19376.1.3.1.5"

From IHE Wiki
Jump to navigation Jump to search
Line 5: Line 5:
 
{{HL7V3|Laboratory Isolate Organizer |1.3.6.1.4.1.19376.1.3.1.5|Trial|
 
{{HL7V3|Laboratory Isolate Organizer |1.3.6.1.4.1.19376.1.3.1.5|Trial|
  
Laboratory Organizer, when present, shall be recorded an organizer in an entryRelationship under the Laboratory data processing entry ([[1.3.6.1.4.1.19376.1.3.1]]) as demonstrated in the figure below. Use of a laboratory organizer is restricted to the grouping of a test battery or a cluster of related laboratory tests.
+
Laboratory Organizer, when present, shall be recorded as an organizer in an entryRelationship under the Laboratory data processing entry ([[1.3.6.1.4.1.19376.1.3.1]]) as demonstrated in the figure below. This module is out of the XDS-Lab Specification. This module does not change requirements stated in that specification but is structured as a module to ensure consistent content representation and re-usability.
 
 
This module is out of the XDS-Lab Specification. This module does not change requirements stated in that specification but is structured as a module to ensure consistent content representation and re-usability.
 
  
 
The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.
 
The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.
Line 41: Line 39:
  
 
=====<templateId root='1.3.6.1.4.1.19376.1.3.1.5'/>=====
 
=====<templateId root='1.3.6.1.4.1.19376.1.3.1.5'/>=====
The <templateId> element identifies this <organizer> as the Laboratory Isolate Organizer.  The templateId shall have root='1.3.6.1.4.1.19376.1.3.1.5'.
+
The <templateId> element identifies this <organizer> as the Laboratory Isolate Organizer.  The templateId shall be recorded as shown above, root='1.3.6.1.4.1.19376.1.3.1.5'.
  
 
=====<statusCode code=" "/>=====
 
=====<statusCode code=" "/>=====
 
The status shall be either "completed" or "obsolete". A status of completed is expected. A status of obsolete means the isolation identification has been replaced by a newer identification (following it) in this revision of the report.
 
The status shall be either "completed" or "obsolete". A status of completed is expected. A status of obsolete means the isolation identification has been replaced by a newer identification (following it) in this revision of the report.
  
NOTE: statusCode is currently not addressed in the LAB TF - needs discussion.
+
NOTE: Lab TF does not address the use of statusCode - needs discussion.
  
 
=====<effectiveTime value=" "/>=====
 
=====<effectiveTime value=" "/>=====
The isolation's relevant clinical time (ideally specimen collection time) should be present.
+
The isolation's relevant clinical time (ideally specimen collection time) MAY be present.
  
 
=====<specimen><specimenRole classCode="ISLT"><specimenPlayingEntity>...</specimen>=====
 
=====<specimen><specimenRole classCode="ISLT"><specimenPlayingEntity>...</specimen>=====
 
The specimenRole shall be "ISLT" and the organism shall be coded with at least one unique international vocabulary.
 
The specimenRole shall be "ISLT" and the organism shall be coded with at least one unique international vocabulary.

Revision as of 13:54, 20 May 2008

Return to: PCC TF-1/PHLAB/XDSLAB Harmonization
Return to: Laboratory Data Processing Entry

Development Only

The PCC Wiki Content is used only for development of IHE PCC Content. The Normative content of the PCC Technical Framework and the current supplements can be found at http://www.ihe.net/Technical_Framework/index.cfm#PCC

Trial.gif Laboratory Isolate Organizer 1.3.6.1.4.1.19376.1.3.1.5

Laboratory Organizer, when present, shall be recorded as an organizer in an entryRelationship under the Laboratory data processing entry (1.3.6.1.4.1.19376.1.3.1) as demonstrated in the figure below. This module is out of the XDS-Lab Specification. This module does not change requirements stated in that specification but is structured as a module to ensure consistent content representation and re-usability.

The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.

Standards
CRS HL7 Care Record Summary
Uses

See Templates using Laboratory Isolate Organizer

Specification
Laboratory Isolate Organizer Example
<ClinicalDocument
  ...
  <component typeCode="COMP">
    <structuredBody classCode="DOCBODY" moodCode="EVN">
      <component typeCode="COMP">
        <section classCode="DOCSECT">
          ...
          <entry typeCode="DRIV">
            <templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3.1"/>
            <act classCode="ACT" moodCode="EVN">
              ...
              <entryRelationship typeCode="COMP">
                <organizer classCode="CLUSTER" moodCode="EVN">
                  <templateId root="1.3.6.1.4.1.19376.1.3.1.5"/>
                  <statusCode code="completed"/>
                  <effectiveTime value="20071108000000.0000-0500"/>
                  <specimen>
                    <specimenRole classCode="ISLT">
                      <specimenPlayingEntity>
                        <code code="79153007" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT" 
                          displayName="Salmonella tennessee 6,7,14;z29;1,2,7">
                          <translation xsi:type="CE" code="L-17601" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED" 
                            displayName="Salmonella tennessee 6,7,14;z29;1,2,7"/>


<templateId root='1.3.6.1.4.1.19376.1.3.1.5'/>

The <templateId> element identifies this <organizer> as the Laboratory Isolate Organizer. The templateId shall be recorded as shown above, root='1.3.6.1.4.1.19376.1.3.1.5'.

<statusCode code=" "/>

The status shall be either "completed" or "obsolete". A status of completed is expected. A status of obsolete means the isolation identification has been replaced by a newer identification (following it) in this revision of the report.

NOTE: Lab TF does not address the use of statusCode - needs discussion.

<effectiveTime value=" "/>

The isolation's relevant clinical time (ideally specimen collection time) MAY be present.

<specimen><specimenRole classCode="ISLT"><specimenPlayingEntity>...</specimen>

The specimenRole shall be "ISLT" and the organism shall be coded with at least one unique international vocabulary.