'''Continued Review of CRC TAVR Document''' | '''Continued Review of CRC TAVR Document''' | ||
:* | :* Charles has cleaned up the document. He has been unable to find a SNOMED code for Device Embolication Left Vtnricle and Dev Embolizttion Aorta. This may be due to the possiblity of the devices being removed. | ||
:* IT has been decided to code the preprocedure and baselines measurements is a results organizaer. There is a SNOMED code, the baseline state, [LOINC refers to them differently] that can be used. SNOMED also has a procedure related findings code which will help denote the approitre code. There is no SNOMED or LOINC code for pre-TAVR measurements. | |||
:* If there are multiple procedures taking place during an intervention, each will require a seperate results organizer. | |||
:* A UID link to DICOM images is required. Some faciliites like UW do not do perform cine imaging or fluoro to keep the radidaiton risk low over a two year follow up process. It sounds ike it shoudl be supported, but not with a 'shall' statement. | |||
Revision as of 09:21, 30 March 2016
Continued Review of CRC TAVR Document
- Charles has cleaned up the document. He has been unable to find a SNOMED code for Device Embolication Left Vtnricle and Dev Embolizttion Aorta. This may be due to the possiblity of the devices being removed.
- IT has been decided to code the preprocedure and baselines measurements is a results organizaer. There is a SNOMED code, the baseline state, [LOINC refers to them differently] that can be used. SNOMED also has a procedure related findings code which will help denote the approitre code. There is no SNOMED or LOINC code for pre-TAVR measurements.
- If there are multiple procedures taking place during an intervention, each will require a seperate results organizer.
- A UID link to DICOM images is required. Some faciliites like UW do not do perform cine imaging or fluoro to keep the radidaiton risk low over a two year follow up process. It sounds ike it shoudl be supported, but not with a 'shall' statement.