| Line 13: | Line 13: | ||
| DICOM MWL IOD || Modality Worklist Provided || DICOM MWM C-Find || {W1-Pull} || | | DICOM MWL IOD || Modality Worklist Provided || DICOM MWM C-Find || {W1-Pull} || | ||
|- | |- | ||
|rowspan="2"| DICOM UPS IOD || ''(Query Worklist)'' || DICOM UPS C-Find || {W2-Pull}, {W4-Pull} || | |rowspan="2"| DICOM UPS IOD || ''(Query Worklist)'' || DICOM UPS C-Find || {W2-Pull},<br> {W4-Pull} || | ||
|- | |- | ||
| ''(Push Workitem)'' || DICOM UPS N-Create|| {W2-Push} || | | ''(Push Workitem)'' || DICOM UPS N-Create|| {W2-Push} || | ||
|- | |- | ||
|rowspan="2"|Images | |rowspan="2"|Images | ||
|rowspan="2"| DICOM Image IODs || Images Stored || DICOM C-Store || {D3-Push}, {D7-Push} || | |rowspan="2"| DICOM Image IODs || Images Stored || DICOM C-Store || {D3-Push}, {D7-Push} || | ||
|- | |- | ||
| Retrieve Images || DICOM C-Store || {D3-Pull} || | | Retrieve Images || DICOM C-Store || {D3-Pull} || | ||
|- | |- | ||
|rowspan="2"|Performed Proc. | |rowspan="2"|Performed Proc. | ||
| DICOM MPPS IOD || Modality Procedure Performed || DICOM N-Set || {D6-Push} || | | DICOM MPPS IOD || Modality Procedure Performed || DICOM N-Set || {D6-Push} || | ||
|- | |- | ||
| Line 35: | Line 35: | ||
| Dictation Audio || ''???'' || ''(Audio Stored)'' || ''???'' || {D6-Push} || | | Dictation Audio || ''???'' || ''(Audio Stored)'' || ''???'' || {D6-Push} || | ||
|- | |- | ||
|rowspan="2"|Radiology Report | |rowspan="2"|Radiology Report <br> (Proto/Draft/Final) | ||
|rowspan="2"| HL7 CDA || ''(D-Report Stored)'' || DICOM C-Store || || | |rowspan="2"| HL7 CDA || ''(D-Report Stored)'' || DICOM C-Store || || | ||
|- | |- | ||
| ''(H-Report Stored)'' || (HL7-Msg) || || | | ''(H-Report Stored)'' || (HL7-Msg) || || | ||
|- | |||
| History/Allergies/ <br>Problems/Meds || HL7 CDA-MS || ??? || ??? || {D20-Pull?} || | |||
|- | |- | ||
|} | |} | ||
Performed Proc. Details HL7 DFT | Performed Proc. Details using HL7 DFT? | ||
Lab Results | Lab Results | ||
| Line 55: | Line 55: | ||
Tech Interview Sheet | Tech Interview Sheet | ||
Bill X12 | Bill X12 | ||
Revision as of 17:47, 2 August 2007
| Artifact | Encoding | Transaction | Transport | Input/Output | |
|---|---|---|---|---|---|
| Patient Account | HL7 PV1 | Patient Update | (HL7 Msg) | {D1-Push} | |
| Order | HL7 ORM | Placer Order Management | (HL7 Msg) | {D2-Push} | |
| Worklist | DICOM MWL IOD | Modality Worklist Provided | DICOM MWM C-Find | {W1-Pull} | |
| DICOM UPS IOD | (Query Worklist) | DICOM UPS C-Find | {W2-Pull}, {W4-Pull} |
||
| (Push Workitem) | DICOM UPS N-Create | {W2-Push} | |||
| Images | DICOM Image IODs | Images Stored | DICOM C-Store | {D3-Push}, {D7-Push} | |
| Retrieve Images | DICOM C-Store | {D3-Pull} | |||
| Performed Proc. | DICOM MPPS IOD | Modality Procedure Performed | DICOM N-Set | {D6-Push} | |
| DICOM UPS IOD | (Procedure Performed) | DICOM UPS N-Get | {Dx-Pull}, {Dy-Pull} | ||
| Performed Proc. | DICOM MPPS IOD | Images Stored | DICOM C-Store | {D4-Push} | |
| Radiation Dose | DICOM SR Dose IOD | (Dose Stored) | DICOM C-Store | {D5-Push} | |
| Procedure Log | DICOM SR PLog IOD | (Procedure Log Stored) | DICOM C-Store | {D6-Push} | |
| Dictation Audio | ??? | (Audio Stored) | ??? | {D6-Push} | |
| Radiology Report (Proto/Draft/Final) |
HL7 CDA | (D-Report Stored) | DICOM C-Store | ||
| (H-Report Stored) | (HL7-Msg) | ||||
| History/Allergies/ Problems/Meds |
HL7 CDA-MS | ??? | ??? | {D20-Pull?} |
Performed Proc. Details using HL7 DFT?
Lab Results
Pathology Results
Patient History Sheet
Tech Interview Sheet
Bill X12
<Material from Section 3 to go in Section 5>
- Investigate CDA as an authoring and distribution format for diagnostic reports
- Two gaps are:
- the lack of CDA report templates for a broad set of Radiology reports
- the lack of deployed implementations using CDA