{{HL7V3|Lab Report Data Processing Entry|1.3.6.1.4.1.19376.1.3.1|Trial|At least one Lab Report Data Processing Entry shall be present. The Entry shall contain a single Act sub-element. This Act is hereafter referred to as the 'Specimen Act'.   
{{HL7V3|Lab Report Data Processing Entry|1.3.6.1.4.1.19376.1.3.1|Trial|At least one Lab Report Data Processing Entry shall be present. The Entry shall contain a single Act sub-element. This Act is hereafter referred to as the 'Specimen Act'.   

Revision as of 14:27, 16 June 2008

Return to: XDS-LAB Harmonization
Return to: Laboratory Content Modules

Development Only

The PCC Wiki Content is used only for development of IHE PCC Content. The Normative content of the PCC Technical Framework and the current supplements can be found at http://www.ihe.net/Technical_Framework/index.cfm#PCC

Lab Report Data Processing Entry 1.3.6.1.4.1.19376.1.3.1

At least one Lab Report Data Processing Entry shall be present. The Entry shall contain a single Act sub-element. This Act is hereafter referred to as the 'Specimen Act'.
The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.


Uses

See Templates using Lab Report Data Processing Entry

Specification
Lab Report Data Processing Entry Example
          <entry typeCode="DRIV">
            <templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3"/>
            <act classCode="ACT" moodCode="EVN">
              <statusCode code="completed"/>

              ... entry contents ...
          </entry>


<templateId root='1.3.6.1.4.1.19376.1.3.1'/>

The <templateId> element identifies this <entry> as a Lab Report Data Processing Entry. The templateId shall have root='1.3.6.1.4.1.19376.1.3.1'.

<act classCode="ACT" moodCode="EVN"/>

There shall be one Act sub-element. This sub-element uses the following modules conforming to the following requirements.

Modules unique to the document body
Sub-Element Opt Description
1.3.6.1.4.1.19376.1.3.1.1 R2 Notification Organizer
1.3.6.1.4.1.19376.1.3.1.1.1 R2 Notifiable Condition
1.3.6.1.4.1.19376.1.3.1.1.2 R2 Case Identifier
1.3.6.1.4.1.19376.1.3.1.1.3 R2 Outbreak Identifier
1.3.6.1.4.1.19376.1.3.1.2 R2 Specimen Collection
1.3.6.1.4.1.19376.1.3.1.3 R2 Specimen Received
1.3.6.1.4.1.19376.1.3.1.4 R2 Laboratory Battery Organizer
1.3.6.1.4.1.19376.1.3.1.5 R2 Laboratory Isolate Organizer
1.3.6.1.4.1.19376.1.3.1.6 R Laboratory Observation
1.3.6.1.4.1.19376.1.5.3.1.4.2 O Annotation Comment (PCC)


Modules with counterparts in the cda header
Sub-Element Opt Description
1.3.6.1.4.1.19376.1.3.3.1.2.1 R2 Non-Human Subject
1.3.6.1.4.1.19376.1.3.3.1.3.1 R2 Human Patient with Non-Human Subject
1.3.6.1.4.1.19376.1.3.3.1.5 O Laboratory Result Verifier
1.3.6.1.4.1.19376.1.3.3.1.7 O Laboratory Performer