PERF Evaluation: Difference between revisions
Jump to navigation
Jump to search
| Line 50: | Line 50: | ||
* Are there IHE-provided software testing tools to address all aspects of the profile? | * Are there IHE-provided software testing tools to address all aspects of the profile? | ||
:* No | :* No | ||
'''TO DO''': Lynn to determine whether any test images exist. Wim indicated that Philips could produce these. Perhaps Sharazone is a source | :* '''TO DO''': Lynn to determine whether any test images exist. Wim indicated that Philips could produce these. Perhaps Sharazone is a source | ||
* Have the standards underlying the profile been implemented? In similar use cases? In healthcare? In general IT? | * Have the standards underlying the profile been implemented? In similar use cases? In healthcare? In general IT? | ||
:* | :* | ||
Revision as of 11:22, 3 April 2025
CT/MR Perfusion Imaging with Contrast (PERF) Final Text Evaluation
Reviewed by IHE RAD Tech on April 3, 2025:
Proposal
The CT/MR Perfusion Imaging with Contrast profile has been nominated for advancement to Final Text. (Advocate: Wim Corbijn) Per the Final Text Process, Items in blue text below warrant Committee discussion.
Technical Committee Checklist
Decision:
- Are all significant CPs against the profile "closed"?
- Currently no active CPs
- Are all significant CPs against the underlying standards "closed"?
- Currently no active CPs. DICOM has been checked.
- Have all significant comments been CP'd or rejected?
- No open comments identified
- Have all open issues listed in the Supplement been closed?
- No open issues, all issues are closed.
- Have all significant issues at Connectathon been dealt with?
- not aware of any issues left from the Connectathons.
- Feedback from implementers.
- No further feedback identified. Latest testing done in 2014 and 2017 Connectathons.
- Has the Connectathon Project Manager been queried and significant issues addressed?
- Yes
Technical Committee Consensus
- It is proposed that the profile ...
Planning Committee Checklist
- Has the profile been through a Connectathon in at least two regions?
- No. North America only. RAD Tech discussed and decided that this is not a barrier to FT because it was fully tested in NA and we don't expect regional variations in implementations for this profile. 10+ years have passed and we don't expect additional testing.
- Has the profile been successfully tested with all actors at least at one Connectathon?
- Yes. NA Connectathon 2014
- Have different implementations of each actor in the profile been tested?
- Modality: Hitachi MR, Philips MR
- Note: No CT modality has tested PERF at a Connectathon
- Image Display: GE
- Image Manager: Karos, Dell, Tiani-Spirit
- Modality: Hitachi MR, Philips MR
- Have all the options been tested successfully at at least one Connectathon?
- Profile does not define any options
- Are there IHE-provided software testing tools to address all aspects of the profile?
- No
- TO DO: Lynn to determine whether any test images exist. Wim indicated that Philips could produce these. Perhaps Sharazone is a source
- Have the standards underlying the profile been implemented? In similar use cases? In healthcare? In general IT?
- (Do you have concrete reason to believe that this works robustly in the Real World) / (Are any products available for purchase that implement the profile?)
- Have all issues that may have been raised about the profile been resolved?
- Has there been sufficient interest in the profile to generate a one-page overview of the profile