PCD Pump 2025-05-12 Teams: Difference between revisions

From IHE Wiki
Jump to navigation Jump to search
Kelliason (talk | contribs)
Kelliason (talk | contribs)
 
Line 45: Line 45:
:'''Chair/Host:'''  ''Kurt Elliason (ICU Medical)''
:'''Chair/Host:'''  ''Kurt Elliason (ICU Medical)''


:'''Participants:'''  ''
:'''Participants:'''  ''Al Engelbert (BBraun), Brendan Burke (Bbraun), Evan O'Grady(Fresenius-Kabi), Javier Becerril (BD), Jeffery Gaetano (BD),  Michael Workman (BD), Paul Schluter (Paul Schluter Consulting), Silas Morris (Epic), Tom Kowalczyk (BBraun)
 
   
   


Line 70: Line 71:
|-
|-
| align="center" | 2
| align="center" | 2
| ''' Agenda topics''' <br>- tbd
| ''' Agenda topics''' <br>- Kurt
| '''Status/Discussion:'''
| '''Status/Discussion:'''


:3a. Multi-step/bolus order examples  
:3a. Multi-step/bolus order examples  
::
:: Add note about adding the step number to IPEC/DEC messages.
:3b. MDC for Volume on screen  
:3b. MDC for Volume on screen  
::  
:: no updates this month, still having internal discussions about how this would be presented to the user.  Defer further discussion of CP and new MDC term in Pump WG until other internal discussions are done.  Use cases for how this workflow would be applied would be helpful.
:3c. PCD-10 example
:3c. PCD-10 example
::
::Need to review the example to verify it matches
:3d. Rack/Stack clarifications and examples  
:3d. Rack/Stack clarifications and examples  
::  
:: Add example message
:4a. PCD-03 Error codes
:4a. PCD-03 Error codes
::
::Reviewing work done so far.
:4b. White paper updates  
:4b. White paper updates  
::
::No updates today
 


'''Decisions/Issues:'''
'''Decisions/Issues:'''
Line 94: Line 96:
|-
|-
| align="center" | 3
| align="center" | 3
| '''TBD''' <br>- tbd
| '''New topics''' <br>- Al
| '''Status/Discussion:'''
| '''Status/Discussion:'''
::New term from F2F to indicate if currently programmed drug is in library or not.
:::Drug provided in PCD-03 but not found in library, pump is programmed with parameters from PCD-03 without library limits.  New term could notify end user that pump is outside its library.
:::Potential terms MDCX_DRUG_IS_IN_LIBRARY  or MDCX_DRUG_NOT_IN_LIBRARY
:::Bool value true or false only. 
:::If we choose MDCX_DRUG_IS_IN_LIBRARY could we assume that it is true if not included?
:::If we choose MDCX_DRUG_NOT_IN_LIBRARY  it could be optional for backward compatibility and only be included when the drug is not in the library, in this case it would always be true, if not included it would be assumed to be false.
:::Check TF for references and possible CP
::Discussed adding new enumerated value to _MDC_PUMP_PROGRAM_COMPLETION_MODE
:::MDC_ENUMGV_PUMP_PROGRAM_COMPLETION_MODE__pump_program_completion_mode_switch_source  "When the program has completed the pump will switch to a different infusate source."





Latest revision as of 12:23, 12 May 2025

(Infusion Pump Main Page)


Meeting Purpose

IHE PCD Infusion Pump Working Group discussions.

WebEx Information

Topic: IHE PCD Infusion Pump WG

Date: Monday, May 12, 2025

Time: 12:00, Eastern Time (GMT -05:00, New York)

Duration: 60 Minutes


Note: Specific web & phone information will be provided via e-mail to group members.

Contact Kurt Elliason for more information.

Proposed Agenda

1. Review today's Agenda
2. Review 2025-04-14 Pump Teams Session
3a. Multi-step/bolus order examples draft CP
3b. MDC for Volume on screen draft CP
3c. PCD-10 example draft CP
3d. Rack/Stack clarifications and examples draft CP
4a. PCD-03 Error codes
4b. White paper updates
5. Review PCD Device Infusion Pump Action Items
6. New Business / Next Meetings

Attachments / Materials

  • <add attachments links here>

Discussion Notes

Chair/Host: Kurt Elliason (ICU Medical)
Participants: Al Engelbert (BBraun), Brendan Burke (Bbraun), Evan O'Grady(Fresenius-Kabi), Javier Becerril (BD), Jeffery Gaetano (BD), Michael Workman (BD), Paul Schluter (Paul Schluter Consulting), Silas Morris (Epic), Tom Kowalczyk (BBraun)



NOTE: Action Item Review updates have been posted directly to the Infusion Pump Action Items wiki page


Item Topic Discussion
1 Agenda & Discussion Notes Review
- Chair
Status/Discussion:


Decisions/Issues:


Action(s):

2 Agenda topics
- Kurt
Status/Discussion:
3a. Multi-step/bolus order examples
Add note about adding the step number to IPEC/DEC messages.
3b. MDC for Volume on screen
no updates this month, still having internal discussions about how this would be presented to the user. Defer further discussion of CP and new MDC term in Pump WG until other internal discussions are done. Use cases for how this workflow would be applied would be helpful.
3c. PCD-10 example
Need to review the example to verify it matches
3d. Rack/Stack clarifications and examples
Add example message
4a. PCD-03 Error codes
Reviewing work done so far.
4b. White paper updates
No updates today


Decisions/Issues:


Action(s):


3 New topics
- Al
Status/Discussion:
New term from F2F to indicate if currently programmed drug is in library or not.
Drug provided in PCD-03 but not found in library, pump is programmed with parameters from PCD-03 without library limits. New term could notify end user that pump is outside its library.
Potential terms MDCX_DRUG_IS_IN_LIBRARY or MDCX_DRUG_NOT_IN_LIBRARY
Bool value true or false only.
If we choose MDCX_DRUG_IS_IN_LIBRARY could we assume that it is true if not included?
If we choose MDCX_DRUG_NOT_IN_LIBRARY it could be optional for backward compatibility and only be included when the drug is not in the library, in this case it would always be true, if not included it would be assumed to be false.
Check TF for references and possible CP
Discussed adding new enumerated value to _MDC_PUMP_PROGRAM_COMPLETION_MODE
MDC_ENUMGV_PUMP_PROGRAM_COMPLETION_MODE__pump_program_completion_mode_switch_source "When the program has completed the pump will switch to a different infusate source."


Decisions/Issues:


Action(s):


4 Next Meeting
- Chair
Status/Discussion:

Decisions/Issues:

  • Topics will include ...

Action(s):


Next Meeting

NOTE: Next Meeting will be held during the regularly scheduled time: 12:00 (Eastern) on June 9 (60 minutes)


(Reviewed & approved by PCD Infusion Pump WG on <TBD>