Line 11: | Line 11: | ||
* Eduardo Olmos - Philips | * Eduardo Olmos - Philips | ||
* Antje Schroeder - Siemens | * Antje Schroeder - Siemens | ||
+ | |||
+ | ''Quorum attained. [https://spreadsheets.google.com/spreadsheet/ccc?key=0At_jYVJ2XnXscFRnSVFzRGZad3M4QXBlRmNQMzQ4V0E&hl=en_US See roster.]'' | ||
==Minutes== | ==Minutes== | ||
− | * Reviewed comments on CP-213 | + | * Reviewed comments on CP-213: ftp://iheyr2@ftp.ihe.net/Radiology/TF_Maintenance/2.Assigned_CPs/CP-RAD-213-CL-PAM%20and%20HL7%20version%202.5.1%20Refactor%205-18-11.doc |
:* Chris Lindop agreed to add a table mapping semantic values between HL7 versions 2.3.1 and 2.5.1 as an appendix to the CP | :* Chris Lindop agreed to add a table mapping semantic values between HL7 versions 2.3.1 and 2.5.1 as an appendix to the CP | ||
:* '''Motion:''' Approve sending CP-213 out for ballot with amendments noted | :* '''Motion:''' Approve sending CP-213 out for ballot with amendments noted |
Latest revision as of 12:34, 11 August 2011
Attendees
- Ellie Avraham - Philips
- Anthony Brockman - Jefferson Radiology
- Chris Carr - RSNA
- Carlos Cervantes -
- Lynn Felhofer - Tech Proj Mgr
- David Heaney - McKesson
- Kinson Ho - Agfa
- Chris Lindop, co-chair - GE
- Takashi Nakashima - Fujifilm
- Eduardo Olmos - Philips
- Antje Schroeder - Siemens
Quorum attained. See roster.
Minutes
- Reviewed comments on CP-213: ftp://iheyr2@ftp.ihe.net/Radiology/TF_Maintenance/2.Assigned_CPs/CP-RAD-213-CL-PAM%20and%20HL7%20version%202.5.1%20Refactor%205-18-11.doc
- Chris Lindop agreed to add a table mapping semantic values between HL7 versions 2.3.1 and 2.5.1 as an appendix to the CP
- Motion: Approve sending CP-213 out for ballot with amendments noted
- Approved unanimously.
- Ballot to be issued on 6/20; will remain open for a maximum of 30 days (until July 20)
- 2011-06-25, 9am CT: Tech Cmte call to review ballot responses
- Motion: If CP-213 is approved, changes described should be incorporated directly into final text document
- Approved unanimously.
- Goal to process comments and prepare changes to Technical Framework for republication in time for IHE North America Connectathon registration (Aug. 22)
- Need additional Technical Committee meeting to review XDS-I and Nuclear Medicine profiles for publication as final text
- 2011-07-12, 12pm CT: Tech Cmte call to review profiles for advancement to final text