Difference between revisions of "1.3.6.1.4.1.19376.1.3.1.3"
Line 1: | Line 1: | ||
− | Return to: [[ | + | Return to:[[PCC_TF-1/PHLAB/XDSLAB_Harmonization | XDS-LAB Harmonization]] |
+ | <br> | ||
+ | Return to:[[PCC_TF-1/PHLAB/XDSLAB_Harmonization#CDA_Document_Content_Modules | Laboratory Content Modules]] | ||
<br> | <br> | ||
Return to: [[1.3.6.1.4.1.19376.1.3.1|Laboratory Data Processing Entry]] | Return to: [[1.3.6.1.4.1.19376.1.3.1|Laboratory Data Processing Entry]] | ||
{{HL7V3|Specimen Received|1.3.6.1.4.1.19376.1.3.1.3|Trial| | {{HL7V3|Specimen Received|1.3.6.1.4.1.19376.1.3.1.3|Trial| | ||
− | Specimen Received, when present, | + | Specimen Received, when present, SHALL be recorded an <act> in an <entryRelationship> under the [[1.3.6.1.4.1.19376.1.3.1|Laboratory Data Processing Entry]] as demonstrated in the figure below. The figure below shows how the information for this element is coded, and further constraints are provided in the following sections. |
− | |||
|Example= | |Example= | ||
<pre> | <pre> |
Revision as of 14:11, 20 June 2008
Return to: XDS-LAB Harmonization
Return to: Laboratory Content Modules
Return to: Laboratory Data Processing Entry
Development Only
The PCC Wiki Content is used only for development of IHE PCC Content. The Normative content of the PCC Technical Framework and the current supplements can be found at http://www.ihe.net/Technical_Framework/index.cfm#PCC
Specimen Received 1.3.6.1.4.1.19376.1.3.1.3
Specimen Received, when present, SHALL be recorded an <act> in an <entryRelationship> under the Laboratory Data Processing Entry as demonstrated in the figure below. The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.
Uses
See Templates using Specimen Received
Specification
<ClinicalDocument ... <component typeCode="COMP"> <structuredBody classCode="DOCBODY" moodCode="EVN"> <component typeCode="COMP"> <section classCode="DOCSECT"> ... <entry typeCode="DRIV"> <templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3"/> <act classCode="ACT" moodCode="EVN"> ... <entryRelationship typeCode="COMP"> <act classCode="ACT" moodCode="EVN"> <templateId root="1.3.6.1.4.1.19376.1.3.1.3"/> <code code=" " codeSystem=" " codeSystemName=" " displayName=" "/> <effectiveTime value=" "/> |
<templateId root="1.3.6.1.4.1.19376.1.3.1.3"/>
The <templateId> element identifies this <act> as the Specimen Received. The templateId shall be recorded as shown above, root='1.3.6.1.4.1.19376.1.3.1.3'.
Seeking code or alternative representation here.
<effectiveTime value=" "/>
The Specimen Received time value.