Difference between revisions of "1.3.6.1.4.1.19376.1.3.1.3"

From IHE Wiki
Jump to navigation Jump to search
(New page: Return to: PCC TF-1/PHLAB/XDSLAB Harmonization {{HL7V3|Specimen Received Date Time|1.3.6.1.4.1.19376.1.3.1.3|Trial| Specimen Received Date Time shall be recorded an act in an entryRel...)
 
Line 2: Line 2:
  
 
{{HL7V3|Specimen Received Date Time|1.3.6.1.4.1.19376.1.3.1.3|Trial|
 
{{HL7V3|Specimen Received Date Time|1.3.6.1.4.1.19376.1.3.1.3|Trial|
Specimen Received Date Time shall be recorded an act in an entryRelationship under the Laboratory data processing entry ([[1.3.6.1.4.1.19376.1.3.1]]) as demonstrated in the figure below.   
+
Specimen Received Date Time, when present, shall be recorded an act in an entryRelationship under the Laboratory data processing entry ([[1.3.6.1.4.1.19376.1.3.1]]) as demonstrated in the figure below.   
  
 
This module is out of the PHLab Specification. This module does not change requirements stated in that specification but is structured as a module to ensure consistent content representation and re-usability. Regarding the XDS-Lab Current Specification, this is an outstanding issue as it is not addressed today.  
 
This module is out of the PHLab Specification. This module does not change requirements stated in that specification but is structured as a module to ensure consistent content representation and re-usability. Regarding the XDS-Lab Current Specification, this is an outstanding issue as it is not addressed today.  
Line 17: Line 17:
 
           ...
 
           ...
 
           <entry typeCode="DRIV">
 
           <entry typeCode="DRIV">
             <templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3.1"/>
+
             <templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3"/>
 
             <act classCode="ACT" moodCode="EVN">
 
             <act classCode="ACT" moodCode="EVN">
 
               ...
 
               ...
 
               <entryRelationship typeCode="COMP">
 
               <entryRelationship typeCode="COMP">
                 <observation classCode="OBS" moodCode="EVN">
+
                 <act classCode="ACT" moodCode="EVN">
                   <templateId root="1.3.6.1.4.1.19376.1.3.1.1"/>
+
                   <templateId root='TBD'/>
                   <code code="170516003" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT"
+
                   <code code="SPC_REC_TBD" codeSystem="2.1.1.1.1.1.1" codeSystemName="TBD"  
                        displayName="Notification of Disease">
 
                    <qualifier>
 
                      <name code="246087005" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT"
 
                            displayName="Source of Specimen"/>
 
                      <value code="116154003" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT"
 
                            displayName="Patient"/>
 
                    </qualifier>
 
                  </code>
 
                  <value xsi:type="CE" code="27268008" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT"
 
                                      displayName="Salmonella">
 
                    <translation code="L-17100" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED"/>
 
                  </value>
 
</pre>
 
 
}}
 
}}
  
 
=====&lt;templateId root='1.3.6.1.4.1.19376.1.3.1.3'/>=====
 
=====&lt;templateId root='1.3.6.1.4.1.19376.1.3.1.3'/>=====
 
The <templateId> element identifies this <act> as the Specimen Received Date Time.  The templateId shall have root='1.3.6.1.4.1.19376.1.3.1.3'.
 
The <templateId> element identifies this <act> as the Specimen Received Date Time.  The templateId shall have root='1.3.6.1.4.1.19376.1.3.1.3'.

Revision as of 17:44, 8 May 2008

Return to: PCC TF-1/PHLAB/XDSLAB Harmonization

Development Only

The PCC Wiki Content is used only for development of IHE PCC Content. The Normative content of the PCC Technical Framework and the current supplements can be found at http://www.ihe.net/Technical_Framework/index.cfm#PCC

Trial.gif Specimen Received Date Time 1.3.6.1.4.1.19376.1.3.1.3

Specimen Received Date Time, when present, shall be recorded an act in an entryRelationship under the Laboratory data processing entry (1.3.6.1.4.1.19376.1.3.1) as demonstrated in the figure below.

This module is out of the PHLab Specification. This module does not change requirements stated in that specification but is structured as a module to ensure consistent content representation and re-usability. Regarding the XDS-Lab Current Specification, this is an outstanding issue as it is not addressed today.

The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.


Uses

See Templates using Specimen Received Date Time

Specification
Specimen Received Date Time Example
<ClinicalDocument
  ...
  <component typeCode="COMP">
    <structuredBody classCode="DOCBODY" moodCode="EVN">
      <component typeCode="COMP">
        <section classCode="DOCSECT">
          ...
          <entry typeCode="DRIV">
            <templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3"/>
            <act classCode="ACT" moodCode="EVN">
              ...
              <entryRelationship typeCode="COMP">
                <act classCode="ACT" moodCode="EVN">
                  <templateId root='TBD'/>
                  =====
The <templateId> element identifies this <act> as the Specimen Received Date Time.  The templateId shall have root='1.3.6.1.4.1.19376.1.3.1.3'.