The blood type observation is a Simple Observation of the patient's blood type. It conforms to the CCD Result observation template.
Standards
CCD | ASTM/HL7 Continuity of Care Document |
Parent Template
The parent of this template is Simple Observation.
Uses
See Templates using Blood Type Observation
Specification
<observation typeCode='OBS' moodCode='EVN'> <templateId root='1.3.6.1.4.1.19376.1.5.3.1.4.13'/> <templateId root='1.3.6.1.4.1.19376.1.5.3.1.4.13.6'/> <templateId root='2.16.840.1.113883.10.20.1.31'/> <id root=' ' extension=' '/> <code code='882-1' displayName='ABO+RH GROUP' codeSystem='2.16.840.1.113883.6.1' codeSystemName='LOINC'/> <text><reference value='#xxx'/></text> <statusCode code='completed'/> <effectiveTime value=' '/> |
<templateId root='1.3.6.1.4.1.19376.1.5.3.1.4.13'/>
<templateId root='1.3.6.1.4.1.19376.1.5.3.1.4.13.6'/>
<templateId root='2.16.840.1.113883.10.20.1.31'/>
These <templateId> elements identify this as a blood type observation. They shall be present in the <observation> element as shown above.
<code code='882-1' displayName='ABO+RH GROUP'
codeSystem='2.16.840.1.113883.6.1'
codeSystemName='LOINC'/>
The <code> element shall be present to represent this as a finding of the patient's composite blood type. It shall use the code and codeSystem attributes shown above.
<repeatNumber value=' '/>
The <repeatNumber> element should not be present in a blood type observation.
<value xsi:type='CE' code=' ' displayName=' '
codeSystem=' ' codeSystemName=' '/>
The <value> element shall be present and shall use the CE data type. The code attribute should be valued using a vocabulary that supports encoding of blood types. The table below shows some coding systems that may be used to encode blood type.
Coding System | OID |
---|---|
ISBT 128 | 2.16.840.1.113883.6.18 |
SNOMED CT | 2.16.840.1.113883.6.96 |
<interpretationCode code=' ' codeSystem=' ' codeSystemName=' '/>
<methodCode code=' ' codeSystem=' ' codeSystemName=' '/>
<targetSiteCode code=' ' codeSystem=' ' codeSystemName=' '/>
<methodCode code=' ' codeSystem=' ' codeSystemName=' '/>
<targetSiteCode code=' ' codeSystem=' ' codeSystemName=' '/>
The <interpretationCode>, <methodCode>, and <targetSiteCode> should not be present in a blood type observation.