Difference between revisions of "Scheduled Workflow 2.0 - Brief Proposal"

From IHE Wiki
Jump to navigation Jump to search
 
(5 intermediate revisions by one other user not shown)
Line 2: Line 2:
 
=IHE Profile Proposal (Brief)=
 
=IHE Profile Proposal (Brief)=
  
''<Delete everything in italics and angle brackets and replace with real text>''
+
==1. Proposed Profile: Radiology Acquisition Workflow==
  
==1. Proposed Profile: Imaging Acquisition Workflow - Radiology==
+
* Proposal Editor: Norinari Honda
 
+
* Editor: Makoto Suzuki
* Proposal Editor: Chris Lindop/Tony Palmer/Nerve Hoehn
 
* Date:    N/A (Wiki keeps history)
 
* Version: N/A (Wiki keeps history)
 
 
* Domain: Radiology and Other Imaging Acquisition Domains
 
* Domain: Radiology and Other Imaging Acquisition Domains
  
 
==2. The Problem==
 
==2. The Problem==
  
The Scheduled Workflow Integration Profile pioneered the use cases for integrating Systems which specialized in Order Placement/Department Scheduling Image Management and Image Acquisition Systems (i.e. CT, MR, US, etc)  with DICOM MPPS. At this time, it was the current “state of integration” for integration order placers with order fillersWhile with Image Managers, the value proposition is clear. PPS provides a mechanism for Image Managers to associate images acquired by modalities with procedures scheduled by Radiology Information SystemsThe value for Radiology Information Systems is less clear. The value provided is minimal and insufficient for a RIS to fully automate workflow based solely on a MPPS message coming from a RIS.
+
Some countries have adopted HL7 V2.5.1 as a national standard.  For vendors deploying systems in such countries, implementing HL7 V2.3 is development overhead with no market value.  Although a V2.5 option has been added to the Scheduled Workflow Profile, it still requires implementing HL7 2.3.  
 +
 
 +
On the other hand, V2.3 and SWF is already in use, we can not abandon it.  Establishing SWF.b with V2.5 as a baseline would resolve the issue.
 +
 
 +
SWF also duplicates functionality described in PAMSWF.b could factor it out.
  
 
==3. Key Use Case==
 
==3. Key Use Case==
  
This Integration profile leverages the same use cases as scheduled workflow at a high level. Some of the key information not addressed by MPPS includes some basics; exam Start, Exam Complete, Technologist performing the acquisition to name a few.
+
The primary use cases would be the same as SWF.
Also missing is key feedback with actionable items for a tech to perform while the study is in session. This would include re-takes, additional protocols, etc.  The current use cases cover this level of interoperability in a generic sense (i.e append). But they do not address the specific needs and is not clearly defined.
+
 
Error conditions are not handled effectively and are in most cases optional.  This revision of scheduled workflow needs to be an upgrade to the existing transactions, making the interfaces truly interoperable.
+
The key discussion will be selecting/scoping additional features (e.g. Exam start/"complete" signals, protocol selection, )
 +
 
 +
Some specific features in HL7 2.5.1 to leverage include:
 +
* Explicit trigger that initiates action of Evidence Creator helps interoperability of systems within the enterprise. <Suzuki-san, can you clarify?>
 +
* Messaging for cancellation, modification, or abortion of (a part of) examination.
 +
* Expandability to cope with local situations:
 +
** Describing exam details in OBR
 +
** Data availability notification such as for urgent reading
 +
** Specifying Study Instance UID
 +
** Exception Management Workflow
 +
** Capacity of ORC for future extension
  
 
==4. Standards & Systems==
 
==4. Standards & Systems==
  
''<List existing systems that are/could be involved in the problem/solution.>''
+
Affected Systems: RIS, PACS, Modalities
 +
 
 +
Standards: DICOM, HL7 V2.5
 +
 
 +
==5. Discussion==
 +
 
 +
===ORM vs OMG/OMI===
 +
ORM should be replaced with OMG. OMG is more robust and capable of handling coded data.
 +
 
 +
OMI will also reduce the number of messaging/processing burden.
  
''<If known, list standards which might be relevant to the solution>''
+
===Data Availabilty Notification===
 +
There is no simple method to signal data and/or resource availability to scheduler. Subscription Request in DICOM UPS may be a solution.
  
 +
===PPS to include imaging protocol===
 +
Imaging/post-processing protocol should be independent UPS or DICOM objects, and they should be defined in DICOM first. And it should be outside of SWF/SWF2.
  
==5. Discussion==
+
===Possible Transaction Changes===
 +
* [RAD-02]: replace ORM with OMG
 +
* [RAD-03]: replace ORM with OMG
 +
* [RAD-04]: replace ORM with OMI
 +
* [RAD-13]: replace ORM with OMI
 +
* [RAD-xx]: add new transaction to notify data/resource availability using OMI
 +
 
 +
===SWF vs SWF.b===
 +
Recommend maintaining both profiles separately rather than more CPs to SWF to keep conformance to SWF2
  
''<Indicate why IHE would be a good venue to solve the problem and what you think IHE should do to solve it.>''
 
  
''<Try to keep the proposal to 1 or at most 2 pages>''
+
HL7 2.5.1 has been defined as standard by the US Department of Health and Human Services in several domains. (http://www.gpo.gov/fdsys/pkg/FR-2010-10-13/pdf/2010-25683.pdf).

Latest revision as of 20:31, 17 August 2012

IHE Profile Proposal (Brief)

1. Proposed Profile: Radiology Acquisition Workflow

  • Proposal Editor: Norinari Honda
  • Editor: Makoto Suzuki
  • Domain: Radiology and Other Imaging Acquisition Domains

2. The Problem

Some countries have adopted HL7 V2.5.1 as a national standard. For vendors deploying systems in such countries, implementing HL7 V2.3 is development overhead with no market value. Although a V2.5 option has been added to the Scheduled Workflow Profile, it still requires implementing HL7 2.3.

On the other hand, V2.3 and SWF is already in use, we can not abandon it. Establishing SWF.b with V2.5 as a baseline would resolve the issue.

SWF also duplicates functionality described in PAM. SWF.b could factor it out.

3. Key Use Case

The primary use cases would be the same as SWF.

The key discussion will be selecting/scoping additional features (e.g. Exam start/"complete" signals, protocol selection, )

Some specific features in HL7 2.5.1 to leverage include:

  • Explicit trigger that initiates action of Evidence Creator helps interoperability of systems within the enterprise. <Suzuki-san, can you clarify?>
  • Messaging for cancellation, modification, or abortion of (a part of) examination.
  • Expandability to cope with local situations:
    • Describing exam details in OBR
    • Data availability notification such as for urgent reading
    • Specifying Study Instance UID
    • Exception Management Workflow
    • Capacity of ORC for future extension

4. Standards & Systems

Affected Systems: RIS, PACS, Modalities

Standards: DICOM, HL7 V2.5

5. Discussion

ORM vs OMG/OMI

ORM should be replaced with OMG. OMG is more robust and capable of handling coded data.

OMI will also reduce the number of messaging/processing burden.

Data Availabilty Notification

There is no simple method to signal data and/or resource availability to scheduler. Subscription Request in DICOM UPS may be a solution.

PPS to include imaging protocol

Imaging/post-processing protocol should be independent UPS or DICOM objects, and they should be defined in DICOM first. And it should be outside of SWF/SWF2.

Possible Transaction Changes

  • [RAD-02]: replace ORM with OMG
  • [RAD-03]: replace ORM with OMG
  • [RAD-04]: replace ORM with OMI
  • [RAD-13]: replace ORM with OMI
  • [RAD-xx]: add new transaction to notify data/resource availability using OMI

SWF vs SWF.b

Recommend maintaining both profiles separately rather than more CPs to SWF to keep conformance to SWF2


HL7 2.5.1 has been defined as standard by the US Department of Health and Human Services in several domains. (http://www.gpo.gov/fdsys/pkg/FR-2010-10-13/pdf/2010-25683.pdf).