Difference between revisions of "PumpErrorCodes"

From IHE Wiki
Jump to navigation Jump to search
m (add link to data files)
 
(6 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
[[Category:PCD]]
 
[[Category:PCD]]
 +
[[Category: PCD Reference Pages]]
  
==Infusion Pump Error Codes (for PCD-03 Ack messages)==
+
==PIV Error Codes (for use in PCD-03 Ack messages)==
 
+
:See appendix B.3 ERR-Error Segment in "IHE Patient Care Device Technical Framework, Vol. 2 (PCD TF-2): Transactions" (https://www.ihe.net/uploadedFiles/Documents/PCD/IHE_PCD_TF_Vol2.pdf) for specific error codes.
Underlying data files in various formats (.xml, .csv, Word) are in ftp://ftp.ihe.net/Patient_Care_Devices/Tools/PumpErrorCodes
 
 
 
Most recent update: 2011-04-13
 
 
 
<table style="border-collapse:collapse; border-style:solid; border-width:1px; padding:0.5em; vertical-align:text-top; " border="1"><tr><th style="width:0.57in; "><span>Value</span></th><th style="width:3.43in; "><span>Description</span></th><th style="width:3.04in; "><span>Comment</span></th></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9001</td><td style="width:3.43in; ">Unknown infuser or channel</td><td style="width:3.04in; ">&nbsp;</td></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9002</td><td style="width:3.43in; ">Infuser/channel is currently infusing</td><td style="width:3.04in; ">&nbsp;</td></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9003</td><td style="width:3.43in; ">Missing required program parameter(s) (ParameterName1, ParameterName2, ...)</td><td style="width:3.04in; ">&nbsp;</td></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9004</td><td style="width:3.43in; ">Invalid program parameter(s) (ParameterName1, ParameterName2, ...)</td><td style="width:3.04in; ">&nbsp;</td></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9005</td><td style="width:3.43in; ">Parameter (ParameterName) outside of allowable range (MinValue to MaxValue)</td><td style="width:3.04in; ">&nbsp;</td></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9006</td><td style="width:3.43in; ">Infuser is powered off</td><td style="width:3.04in; ">&nbsp;</td></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9007</td><td style="width:3.43in; ">Infuser is offline or unable to connect to infuser</td><td style="width:3.04in; ">&nbsp;</td></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9008</td><td style="width:3.43in; ">Invalid units for parameter (ParameterName)</td><td style="width:3.04in; ">&nbsp;</td></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9009</td><td style="width:3.43in; ">Dose/Rate Units do not match drug library</td><td style="width:3.04in; ">&nbsp;</td></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9010</td><td style="width:3.43in; ">Unable to match medication to drug library</td><td style="width:3.04in; ">&nbsp;</td></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9011</td><td style="width:3.43in; ">Patient weight mismatch</td><td style="width:3.04in; ">&nbsp;</td></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9012</td><td style="width:3.43in; ">Patient ID mismatch</td><td style="width:3.04in; ">&nbsp;</td></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9013</td><td style="width:3.43in; ">Unable to program medication as piggyback</td><td style="width:3.04in; ">&nbsp;</td></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9014</td><td style="width:3.43in; ">Dose rate or VTBI exceeds maximum</td><td style="width:3.04in; ">&nbsp;</td></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9015</td><td style="width:3.43in; ">Request timed out</td><td style="width:3.04in; ">&nbsp;</td></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9016</td><td style="width:3.43in; ">Unknown error</td><td style="width:3.04in; ">&nbsp;</td></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9017</td><td style="width:3.43in; ">Infuser cannot accept program</td><td style="width:3.04in; ">&nbsp;</td></tr><tr style="border-collapse:collapse; border-spacing:0; border-style:solid; border-width:thin; empty-cells:show; font-family:Arial; font-size:small; margin:0; "><td style="width:0.57in; ">9018</td><td style="width:3.43in; ">Parameter (ParameterName) does not match drug library</td><td style="width:3.04in; ">&nbsp;</td></tr></table>
 

Latest revision as of 11:10, 9 July 2018


PIV Error Codes (for use in PCD-03 Ack messages)

See appendix B.3 ERR-Error Segment in "IHE Patient Care Device Technical Framework, Vol. 2 (PCD TF-2): Transactions" (https://www.ihe.net/uploadedFiles/Documents/PCD/IHE_PCD_TF_Vol2.pdf) for specific error codes.