Difference between revisions of "PCD Technical Framework"

From IHE Wiki
Jump to navigation Jump to search
(update terribly outdated into)
(transclude transaction list)
Line 20: Line 20:
  
  
:{|border="2"
+
{{ :PCD_Transaction_List }}
|-
 
! width="7%"  align="center" |ID
 
! width="25%"  align="left"  |Transaction Title
 
! width="7%"  align="center" |Profile
 
! width="25%"  aligh="left"  |Source Actor
 
! width="25%"  align="left"  |Receiving Actor
 
!              aligh="left"  |Notes
 
|-
 
| align="center" | PCD-01
 
| Communicate PCD Data
 
| align="center" | [[PCD_Profile_DEC_Overview | DEC]]
 
| Device Observation Reporter (DOR)
 
| Device Observation Consumer (DOC)
 
|
 
|-
 
| align="center" | PCD-02
 
| Subscribe to PCD Data
 
| align="center" | [[PCD_Profile_DEC_Overview | SPD]]
 
| Device Observation Consumer (DOC)
 
| Device Observation Filter (DOF)
 
|
 
|-
 
| align="center" | PCD-03
 
| Communicate Infusion Order
 
| align="center" | [[PCD_Profile_Point-of-Care_Infusion_Verification | PIV]]
 
| Infusion Order Programmer (IOP)
 
| Infusion Order Consumer (IOC)
 
|
 
|-
 
| align="center" | PCD-04
 
| Report Alarm
 
| align="center" | [[PCD_Profile_Alarm_Communication_Management | ACM]]
 
| Alarm Reporter (AR)
 
| Alarm Manager (AM)
 
| ''Formerly ACM-01''
 
|-
 
| align="center" | PCD-05
 
| Report Alarm Status
 
| align="center" | [[PCD_Profile_Alarm_Communication_Management | ACM]]
 
| Alarm Manager (AM)
 
| Alarm Reporter (AR)
 
| ''Formerly ACM-02''
 
|-
 
| align="center" | PCD-06
 
| Disseminate Alarm
 
| align="center" | [[PCD_Profile_Alarm_Communication_Management | ACM]]
 
| Alarm Manager (AM)
 
| Alarm Communicator (AC)
 
| ''Formerly ACM-03''
 
|-
 
| align="center" | PCD-07
 
| Report Dissemination Alarm Status
 
| align="center" | [[PCD_Profile_Alarm_Communication_Management | ACM]]
 
| Alarm Communicator (AC)
 
| Alarm Manager (AM)
 
| ''Formerly ACM-04''
 
|-
 
| align="center" | PCD-08
 
| (Reserved)
 
| align="center" | [[PCD_Profile_Alarm_Communication_Management | ACM]]
 
|  
 
|  
 
|  
 
|-
 
| align="center" | PCD-09
 
| Communicate IDC Observation
 
| align="center" | [[PCD_Profile_Implantable_Device_Cardiac_Observation | IDCO]]
 
| Device Observation Reporter (DOR)
 
| Device Observation Consumer (DOC)
 
| [http://www.idcstandards.com-a.googlepages.com/ IDC WG Web Page]
 
|-
 
| align="center" | PCD-10
 
| Communicate Infusion Pump Event
 
| align="center" | IPEC
 
| Device Observation Reporter (DOR)
 
| Device Observation Consumer (DOC)
 
|  
 
|-
 
| align="center" | PCD-11
 
| (Reserved)
 
| align="center" | ACM
 
|  
 
|  
 
|  
 
|-
 
| align="center" | PCD-12
 
| Asynchronous Data Query
 
| align="center" | ADQ
 
| Asynchronous Data Consumer (ADC)
 
| Asynchronous Data Reporter(ADR)
 
|  
 
|-
 
| align="center" | PCD-13
 
| Asynchronous Data Reply
 
| align="center" | ADQ
 
| Asynchronous Data Reporter(ADR)
 
| Asynchronous Data Consumer (ADC)
 
|  
 
|-
 
| align="center" | PCD-14
 
| Associate / Disassociate Patient and Devices
 
| align="center" | PCIM
 
| Patient Device Association Reporter (PDAR)
 
| Patient Device Association Consumer(PDAC)
 
|  
 
|}
 
  
 
==Public Comments Archive==
 
==Public Comments Archive==
 
You can find an archive of early public comments on PCD documents at http://forums.rsna.org/forumdisplay.php?f=347.
 
You can find an archive of early public comments on PCD documents at http://forums.rsna.org/forumdisplay.php?f=347.

Revision as of 08:33, 19 April 2014

Overview

The IHE PCD Technical Framework is composed of a set of profiles that address specific integration scenarios that include at least one regulated medical device (per the PCD Charter).

<volume 1> <volume 2> <volume 3>

Current Framework Status

 Links to current versions of all volumes of the IHE PCD Technical Framework, and current IHE PCD Framework Supplements, may be found at:

ihe.net PCD Technical Frameworks listing

PCD Transaction Map

Many of the PCD Profiles include transactions, specified in the Technical Framework Volume 2 Transactions, which are allocated on a domain basis. This table identifies the currently allocated transactions and the profiles to which they belong:


ID Transaction Title Profile Source Actor Receiving Actor Notes
PCD-01 Communicate PCD Data DEC Device Observation Reporter (DOR) Device Observation Consumer (DOC)
PCD-02 Subscribe to PCD Data SPD Device Observation Consumer (DOC) Device Observation Filter (DOF)
PCD-03 Communicate Infusion Order PIV Infusion Order Programmer (IOP) Infusion Order Consumer (IOC)
PCD-04 Report Alarm ACM Alarm Reporter (AR) Alarm Manager (AM) Formerly ACM-01
PCD-05 Report Alarm Status ACM Alarm Manager (AM) Alarm Reporter (AR) Formerly ACM-02
PCD-06 Disseminate Alarm ACM Alarm Manager (AM) Alarm Communicator (AC) Formerly ACM-03
PCD-07 Report Dissemination Alarm Status ACM Alarm Communicator (AC) Alarm Manager (AM) Formerly ACM-04
PCD-08 (Reserved) ACM      
PCD-09 Communicate IDC Observation IDCO Device Observation Reporter (DOR) Device Observation Consumer (DOC) IDC WG Web Page
PCD-10 Communicate Infusion Pump Event IPEC Device Observation Reporter (DOR) Device Observation Consumer (DOC)  
PCD-11 (Reserved) ACM      
PCD-12 Retrospective Data Query RDQ Retrospective Data Consumer (RDC) Retrospective Data Reporter(RDR)  
PCD-13 Retrospective Data Reply RDQ Retrospective Data Reporter(RDR) Retrospective Data Consumer (RDC)  
PCD-14 (Reserved)        
PCD-15 Device Management Information Observation (DMIO) MEMDMC Device Management Information Reporter (DMIR) Device Management Information Consumer (DMIC)  
PCD-16 Report Location Observation (RLO) MEMLS Location Observation Reporter (LOR) Location Observation Consumer (LOC)  
PCD-17 (Reserved)       Deprecated, use DEV-51
PCD-18 (Reserved)       Deprecated, use DEV-51
PCD-19 Query Device-Patient Associations PCIM Device-Patient Association Consumer(DPAC) Device-Patient Association Manager (DPAM)  
PCD-20 Register Device PCIM Device Registrant (DREG) Device-Patient Association Manager (DPAM)  

Hyperlinks need to be updated

Public Comments Archive

You can find an archive of early public comments on PCD documents at http://forums.rsna.org/forumdisplay.php?f=347.