Difference between revisions of "PCD Technical Framework"
(a c) |
m (add PCD-11 to 14) |
||
Line 107: | Line 107: | ||
| Device Observation Reporter (DOR) | | Device Observation Reporter (DOR) | ||
| Device Observation Consumer (DOC) | | Device Observation Consumer (DOC) | ||
+ | | | ||
+ | |- | ||
+ | | align="center" | PCD-11 | ||
+ | | (Reserved) | ||
+ | | align="center" | ACM | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | | align="center" | PCD-12 | ||
+ | | Asynchronous Data Query | ||
+ | | align="center" | ADQ | ||
+ | | Asynchronous Data Consumer (ADC) | ||
+ | | Asynchronous Data Reporter(ADR) | ||
+ | | | ||
+ | |- | ||
+ | | align="center" | PCD-13 | ||
+ | | Asynchronous Data Reply | ||
+ | | align="center" | ADQ | ||
+ | | Asynchronous Data Reporter(ADR) | ||
+ | | Asynchronous Data Consumer (ADC) | ||
+ | | | ||
+ | |- | ||
+ | | align="center" | PCD-14 | ||
+ | | | ||
+ | | align="center" | PCIM | ||
+ | | | ||
+ | | | ||
| | | | ||
|} | |} |
Revision as of 13:27, 22 May 2012
Overview
The IHE PCD Technical Framework is composed of a set of profiles that address specific integration scenarios that include at least one regulated medical device (per the PCD Charter).
<volume 1> <volume 2> <volume 3>
Current Framework Status
The current PCD technical framework for Trial Implementation is is rev. 1.2, September 30, 2010.
2011-03-21 Final Text versions of Technical Framework volume 1 (ftp://ftp.ihe.net/Patient_Care_Devices/TechnicalFrameworkFinalText/IHE_PCD_TF_Vol1_FT_2010-11-22Draft.doc)
and volume 2 (ftp://ftp.ihe.net/Patient_Care_Devices/TechnicalFrameworkFinalText/IHE_PCD_TF_Vol2_FT_2011-03-21Draft.doc) are out for Technical Committee review.
See ftp://ftp.ihe.net/Patient_Care_Devices/TechnicalFrameworkFinalText/IHE-PCD_Change_Proposal%20TF_FT_Vol1.doc for Volume 1 Change Proposal.
See PCD_Technical_Framework_Volume_2_Issue_List for a list of Volume 2 changes compared to the first balloted version.
See PCD Technical Framework Volume 2 Final Text version 2011-03-21 Change Proposals for the Change Proposals associated with the changes to Volume 2.
PCD_Technical_Framework_vol._2_Errata
PCD Transaction Map
Many of the PCD Profiles include transactions, specified in the Technical Framework Volume 2 Transactions, which are allocated on a domain basis. This table identifies the currently allocated transactions and the profiles to which they belong:
ID Transaction Title Profile Source Actor Receiving Actor Notes PCD-01 Communicate PCD Data DEC Device Observation Reporter (DOR) Device Observation Consumer (DOC) PCD-02 Subscribe to PCD Data SPD Device Observation Consumer (DOC) Device Observation Filter (DOF) PCD-03 Communicate Infusion Order PIV Infusion Order Programmer (IOP) Infusion Order Consumer (IOC) PCD-04 Report Alarm ACM Alarm Reporter (AR) Alarm Manager (AM) Formerly ACM-01 PCD-05 Report Alarm Status ACM Alarm Manager (AM) Alarm Reporter (AR) Formerly ACM-02 PCD-06 Disseminate Alarm ACM Alarm Manager (AM) Alarm Communicator (AC) Formerly ACM-03 PCD-07 Report Dissemination Alarm Status ACM Alarm Communicator (AC) Alarm Manager (AM) Formerly ACM-04 PCD-08 Subscribe to Alarm ACM Alarm Archiver (AA) Alarm Manager (AM) Formerly ACM-06 PCD-09 Communicate IDC Observation IDCO Device Observation Reporter (DOR) Device Observation Consumer (DOC) IDC WG Web Page PCD-10 Communicate Infusion Pump Event IPEC Device Observation Reporter (DOR) Device Observation Consumer (DOC) PCD-11 (Reserved) ACM PCD-12 Asynchronous Data Query ADQ Asynchronous Data Consumer (ADC) Asynchronous Data Reporter(ADR) PCD-13 Asynchronous Data Reply ADQ Asynchronous Data Reporter(ADR) Asynchronous Data Consumer (ADC) PCD-14 PCIM
Public Comments Archive
You can find an archive of early public comments on PCD documents at http://forums.rsna.org/forumdisplay.php?f=347.