==Overview== | ==Overview== | ||
− | |||
− | |||
− | |||
− | |||
− | + | ::'''NOTE: This page has been superseded by the [[DEV Technical Framework]] page, starting with the 2020 Edition (10.0) of the IHE Devices TF. All current information is located on that page.''' | |
− | |||
− | is | ||
− | |||
− | + | The [https://www.ihe.net/resources/technical_frameworks/#pcd IHE PCD Technical Framework] is composed of a set of profiles that address specific integration scenarios that include at least one regulated medical device (per the [[Patient_Care_Device#Domain_Overview | PCD Charter]]). | |
− | + | * [http://www.ihe.net/uploadedFiles/Documents/PCD/IHE_PCD_TF_Vol1.pdf Vol. 1 (PCD TF-1): Integration Profiles] | |
+ | * [http://www.ihe.net/uploadedFiles/Documents/PCD/IHE_PCD_TF_Vol2.pdf Vol. 2 (PCD TF-2): Transactions] | ||
+ | * [http://www.ihe.net/uploadedFiles/Documents/PCD/IHE_PCD_TF_Vol3.pdf Vol. 3 (PCD TF-3): Semantic Content] | ||
− | + | ==Current Framework Status== | |
− | + | Links to current versions of all volumes of the IHE PCD Technical Framework, and current IHE PCD Framework Supplements, may be found at: | |
− | |||
− | [ | + | [http://ihe.net/Technical_Frameworks/#pcd PCD Technical Frameworks listing on ihe.net] |
==PCD Transaction Map== | ==PCD Transaction Map== | ||
Line 30: | Line 25: | ||
− | : | + | {{ :PCD_Transaction_List }} |
− | + | ||
− | + | ==PCH Transaction Map== | |
− | + | ||
− | + | {{ :PCH_Transaction_List }} | |
− | + | ||
− | + | ==Technical Framework Section Numbers for Profiles== | |
− | + | ||
− | + | {| class="wikitable" | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | ! Section !! Profile | |
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 3 || Device Enterprise Communication (DEC) |
− | | ( | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 4 || Point-of-Care Infusion Verification (PIV) |
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 5 || Implantable Device - Cardiac - Observation |
− | |||
− | |||
− | | Device Observation | ||
− | |||
− | |||
|- | |- | ||
− | | | + | | 6 || Alert Communication Management (ACM) |
− | | ( | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 7 || Infusion Pump Event Communication (IPEC) |
− | | | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 8 || Reserved - Point-of-Care Identity Management (PCIM) |
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 9 || Reserved - Personal Health Device Observation Upload (POU) |
− | |||
− | |||
− | |||
− | |||
− | |||
|} | |} | ||
==Public Comments Archive== | ==Public Comments Archive== | ||
You can find an archive of early public comments on PCD documents at http://forums.rsna.org/forumdisplay.php?f=347. | You can find an archive of early public comments on PCD documents at http://forums.rsna.org/forumdisplay.php?f=347. |
Revision as of 12:47, 10 July 2020
Overview
- NOTE: This page has been superseded by the DEV Technical Framework page, starting with the 2020 Edition (10.0) of the IHE Devices TF. All current information is located on that page.
The IHE PCD Technical Framework is composed of a set of profiles that address specific integration scenarios that include at least one regulated medical device (per the PCD Charter).
- Vol. 1 (PCD TF-1): Integration Profiles
- Vol. 2 (PCD TF-2): Transactions
- Vol. 3 (PCD TF-3): Semantic Content
Current Framework Status
Links to current versions of all volumes of the IHE PCD Technical Framework, and current IHE PCD Framework Supplements, may be found at:
PCD Technical Frameworks listing on ihe.net
PCD Transaction Map
Many of the PCD Profiles include transactions, specified in the Technical Framework Volume 2 Transactions, which are allocated on a domain basis. This table identifies the currently allocated transactions and the profiles to which they belong:
ID | Transaction Title | Profile | Source Actor | Receiving Actor | Notes |
---|---|---|---|---|---|
PCD-01 | Communicate PCD Data | DEC | Device Observation Reporter (DOR) | Device Observation Consumer (DOC) | |
PCD-02 | Subscribe to PCD Data | SPD | Device Observation Consumer (DOC) | Device Observation Filter (DOF) | |
PCD-03 | Communicate Infusion Order | PIV | Infusion Order Programmer (IOP) | Infusion Order Consumer (IOC) | |
PCD-04 | Report Alarm | ACM | Alarm Reporter (AR) | Alarm Manager (AM) | Formerly ACM-01 |
PCD-05 | Report Alarm Status | ACM | Alarm Manager (AM) | Alarm Reporter (AR) | Formerly ACM-02 |
PCD-06 | Disseminate Alarm | ACM | Alarm Manager (AM) | Alarm Communicator (AC) | Formerly ACM-03 |
PCD-07 | Report Dissemination Alarm Status | ACM | Alarm Communicator (AC) | Alarm Manager (AM) | Formerly ACM-04 |
PCD-08 | (Reserved) | ACM | |||
PCD-09 | Communicate IDC Observation | IDCO | Device Observation Reporter (DOR) | Device Observation Consumer (DOC) | IDC WG Web Page |
PCD-10 | Communicate Infusion Pump Event | IPEC | Device Observation Reporter (DOR) | Device Observation Consumer (DOC) | |
PCD-11 | (Reserved) | ACM | |||
PCD-12 | Retrospective Data Query | RDQ | Retrospective Data Consumer (RDC) | Retrospective Data Reporter(RDR) | |
PCD-13 | Retrospective Data Reply | RDQ | Retrospective Data Reporter(RDR) | Retrospective Data Consumer (RDC) | |
PCD-14 | (Reserved) | ||||
PCD-15 | Device Management Information Observation (DMIO) | MEMDMC | Device Management Information Reporter (DMIR) | Device Management Information Consumer (DMIC) | |
PCD-16 | Report Location Observation (RLO) | MEMLS | Location Observation Reporter (LOR) | Location Observation Consumer (LOC) | |
PCD-17 | (Reserved) | Deprecated, use DEV-51 | |||
PCD-18 | (Reserved) | Deprecated, use DEV-51 | |||
PCD-19 | Query Device-Patient Associations | PCIM | Device-Patient Association Consumer(DPAC) | Device-Patient Association Manager (DPAM) | |
PCD-20 | Register Device | PCIM | Device Registrant (DREG) | Device-Patient Association Manager (DPAM) |
Hyperlinks need to be updated
PCH Transaction Map
ID | Transaction Title | Profile | Source Actor | Receiving Actor | Notes |
---|---|---|---|---|---|
PCH-01 | Communicate FHIR PHD Data | POU | Device Observation Reporter | Device Observation Consumer | |
PCH-02 | Communicate RESTful PHD Data | POU | Device Observation Reporter | Device Observation Consumer |
Technical Framework Section Numbers for Profiles
Section | Profile |
---|---|
3 | Device Enterprise Communication (DEC) |
4 | Point-of-Care Infusion Verification (PIV) |
5 | Implantable Device - Cardiac - Observation |
6 | Alert Communication Management (ACM) |
7 | Infusion Pump Event Communication (IPEC) |
8 | Reserved - Point-of-Care Identity Management (PCIM) |
9 | Reserved - Personal Health Device Observation Upload (POU) |