Difference between revisions of "PCD Pump 2022-01-10 Zoom"

From IHE Wiki
Jump to navigation Jump to search
 
(8 intermediate revisions by the same user not shown)
Line 24: Line 24:
 
:1.  Review today's Agenda
 
:1.  Review today's Agenda
 
:2.  Review [[PCD_Pump_2021-12-13_Zoom | 2021-12-13 Pump Zoom Session]]
 
:2.  Review [[PCD_Pump_2021-12-13_Zoom | 2021-12-13 Pump Zoom Session]]
:3.   
+
:3.  Discussion of MDC_FLOW_FLUID_PUMP, MDC_FLOW_FLUID_PUMP_CURRENT, MDC_FLOW_FLUID_PUMP_SETTING
:4.   
+
:4.  Review containment draft for pcd-01 - enumerations
 
:5.  Review [[PCD Device Infusion Pump Action Items | PCD Device Infusion Pump Action Items]]
 
:5.  Review [[PCD Device Infusion Pump Action Items | PCD Device Infusion Pump Action Items]]
 
:6.  New Business / Next Meetings
 
:6.  New Business / Next Meetings
Line 32: Line 32:
  
 
:* '''<add attachments links here>'''
 
:* '''<add attachments links here>'''
 
+
:[https://docs.google.com/spreadsheets/d/1ux3JQlZ21cjdFVW5I5r2T7sPpztwEtnD/edit?usp=sharing&ouid=108127959796856836161&rtpof=true&sd=true PCD03 containment for discussion]
  
 
== Discussion Notes ==
 
== Discussion Notes ==
Line 38: Line 38:
 
:'''Chair/Host:'''  ''Kurt Elliason (Smiths Medical)''
 
:'''Chair/Host:'''  ''Kurt Elliason (Smiths Medical)''
  
:'''Participants:'''  ''  
+
:'''Participants:'''  '' Adam Bunton(Cerner), Al Engelbert (BBraun), Andrea Robertson (Smiths), Brian Sullivan(BD), Brian Witkowski (BBraun), Jeff Rinda (Interoperability Solutions), Paul Schluter (), Rachel Golan (Root3 Labs), Steve Dain(), Tom Kowalczyk (BBraun);
 +
 
  
  
Line 63: Line 64:
 
|-
 
|-
 
| align="center" | 2
 
| align="center" | 2
| '''tbd''' <br>- tbd
+
| '''MDC_FLOW_FLUID_PUMP''' <br>- Chair + Steve Dain
 
| '''Status/Discussion:'''
 
| '''Status/Discussion:'''
 +
:Existing term MDC_FLOW_FLUID_PUMP  26712 (secondary refid as MDC_RATE_INFUS)  which is currently defined as  "Volume rate delivered by pump" in the 10101:2019 and is defined differently as "Programmed volumetric delivery rate" in latest PCD10 containment spreadsheet 
 +
:New proposed term MDC_FLOW_FLUID_PUMP_CURRENT code 26942  defined as "current pump fluid flow"
 +
:Historically we have used 26712 as the flow of the pump. 
 +
:Pump WG desired to communicate what the pump rate is set at, even when the pump is not infusing.
 +
:We may have created some difficulties with the proposed term and the "new" definition of an old term.
 +
:Suggestion is to delete the proposed term MDC_FLOW_FLUID_PUMP_CURRENT, clarifying the definition of MDC_FLOW_FLUID_PUMP  26712 as "current fluid volume rate delivered by the pump"
 +
:Create a new term MDC_FLOW_FLUID_PUMP_SETTING with the definition "current fluid volume rate setting"  Note: This represents the current set rate with the pump either in standby or infusing
  
  
 
'''Decisions/Issues:'''
 
'''Decisions/Issues:'''
 
+
:Need to look at whether it is an observation or a setting
 +
:MDC_FLOW_FLUID_PUMP and MDC_FLOW_FLUID_PUMP_CURRENT end up being the same and will be used to report the current rate.  _CURRENT has been used in the TF since 2019 and is used in some pump implementations.
 +
:MDC_FLOW_FLUID_PUMP_SETTING will be used for PCD-03 to program and in PCD-01/10 to report what it is programmed to do.  Added to containment model, based on MDC_FLOW_FLUID_PUMP with part = 258 instead of 2
  
 
'''Action(s):'''
 
'''Action(s):'''
Line 75: Line 85:
 
|-
 
|-
 
| align="center" | 3
 
| align="center" | 3
| '''tbd''' <br>- tbd
+
| '''PCD01 Containment''' <br>- Kurt
 
| '''Status/Discussion:'''
 
| '''Status/Discussion:'''
  
  
 
'''Decisions/Issues:'''
 
'''Decisions/Issues:'''
 
+
:_MDC_ATTR_AL_COND_PUMP_GENERAL should be _MDC_ATTR_AL_COND for MDC_ATTR_AL_COND
 +
: Missing enum values for _MDC_PUMP_DOSE_DELAY_INTERVAL_TYPE
  
 
'''Action(s):'''
 
'''Action(s):'''

Latest revision as of 13:46, 10 January 2022

(Infusion Pump Main Page)


Meeting Purpose

IHE PCD Infusion Pump Working Group discussions.

WebEx Information

Topic: IHE PCD Infusion Pump WG

Date: Monday, Jan 10, 2022

Time: 12:00, Eastern Time (GMT -05:00, New York)

Duration: 60 Minutes


Note: Specific web & phone information will be provided via e-mail to group members.

Contact Kurt Elliason for more information.

Proposed Agenda

1. Review today's Agenda
2. Review 2021-12-13 Pump Zoom Session
3. Discussion of MDC_FLOW_FLUID_PUMP, MDC_FLOW_FLUID_PUMP_CURRENT, MDC_FLOW_FLUID_PUMP_SETTING
4. Review containment draft for pcd-01 - enumerations
5. Review PCD Device Infusion Pump Action Items
6. New Business / Next Meetings

Attachments / Materials

  • <add attachments links here>
PCD03 containment for discussion

Discussion Notes

Chair/Host: Kurt Elliason (Smiths Medical)
Participants: Adam Bunton(Cerner), Al Engelbert (BBraun), Andrea Robertson (Smiths), Brian Sullivan(BD), Brian Witkowski (BBraun), Jeff Rinda (Interoperability Solutions), Paul Schluter (), Rachel Golan (Root3 Labs), Steve Dain(), Tom Kowalczyk (BBraun);



NOTE: Action Item Review updates have been posted directly to the Infusion Pump Action Items wiki page


Item Topic Discussion
1 Agenda & Discussion Notes Review
- Chair
Status/Discussion:


Decisions/Issues:


Action(s):

2 MDC_FLOW_FLUID_PUMP
- Chair + Steve Dain
Status/Discussion:
Existing term MDC_FLOW_FLUID_PUMP 26712 (secondary refid as MDC_RATE_INFUS) which is currently defined as "Volume rate delivered by pump" in the 10101:2019 and is defined differently as "Programmed volumetric delivery rate" in latest PCD10 containment spreadsheet
New proposed term MDC_FLOW_FLUID_PUMP_CURRENT code 26942 defined as "current pump fluid flow"
Historically we have used 26712 as the flow of the pump.
Pump WG desired to communicate what the pump rate is set at, even when the pump is not infusing.
We may have created some difficulties with the proposed term and the "new" definition of an old term.
Suggestion is to delete the proposed term MDC_FLOW_FLUID_PUMP_CURRENT, clarifying the definition of MDC_FLOW_FLUID_PUMP 26712 as "current fluid volume rate delivered by the pump"
Create a new term MDC_FLOW_FLUID_PUMP_SETTING with the definition "current fluid volume rate setting" Note: This represents the current set rate with the pump either in standby or infusing


Decisions/Issues:

Need to look at whether it is an observation or a setting
MDC_FLOW_FLUID_PUMP and MDC_FLOW_FLUID_PUMP_CURRENT end up being the same and will be used to report the current rate. _CURRENT has been used in the TF since 2019 and is used in some pump implementations.
MDC_FLOW_FLUID_PUMP_SETTING will be used for PCD-03 to program and in PCD-01/10 to report what it is programmed to do. Added to containment model, based on MDC_FLOW_FLUID_PUMP with part = 258 instead of 2

Action(s):


3 PCD01 Containment
- Kurt
Status/Discussion:


Decisions/Issues:

_MDC_ATTR_AL_COND_PUMP_GENERAL should be _MDC_ATTR_AL_COND for MDC_ATTR_AL_COND
Missing enum values for _MDC_PUMP_DOSE_DELAY_INTERVAL_TYPE

Action(s):


4 Next Meeting
- Chair
Status/Discussion:

Decisions/Issues:

  • Topics will include ...

Action(s):


Next Meeting

NOTE: Next Meeting will be held during the regularly scheduled time: 12:00 (Eastern) on Jan 24 (60 minutes)


(Reviewed & approved by PCD Infusion Pump WG on <TBD>


PCD Home