Difference between revisions of "PCD Pump 2022-01-10 Zoom"

From IHE Wiki
Jump to navigation Jump to search
Line 63: Line 63:
 
|-
 
|-
 
| align="center" | 2
 
| align="center" | 2
| '''tbd''' <br>- tbd
+
| '''MDC_FLOW_FLUID_PUMP''' <br>- Chair + Steve Dain
 
| '''Status/Discussion:'''
 
| '''Status/Discussion:'''
 
:Existing term MDC_FLOW_FLUID_PUMP  26712 (secondary refid as MDC_RATE_INFUS)  which is currently defined as  "Volume rate delivered by pump" in the 10101:2019 and is defined differently as "Programmed volumetric delivery rate" in latest PCD10 containment spreadsheet   
 
:Existing term MDC_FLOW_FLUID_PUMP  26712 (secondary refid as MDC_RATE_INFUS)  which is currently defined as  "Volume rate delivered by pump" in the 10101:2019 and is defined differently as "Programmed volumetric delivery rate" in latest PCD10 containment spreadsheet   
Line 82: Line 82:
 
|-
 
|-
 
| align="center" | 3
 
| align="center" | 3
| '''tbd''' <br>- tbd
+
| '''PCD03 Containment''' <br>- tbd
 
| '''Status/Discussion:'''
 
| '''Status/Discussion:'''
  

Revision as of 11:54, 22 December 2021

(Infusion Pump Main Page)


Meeting Purpose

IHE PCD Infusion Pump Working Group discussions.

WebEx Information

Topic: IHE PCD Infusion Pump WG

Date: Monday, Jan 10, 2022

Time: 12:00, Eastern Time (GMT -05:00, New York)

Duration: 60 Minutes


Note: Specific web & phone information will be provided via e-mail to group members.

Contact Kurt Elliason for more information.

Proposed Agenda

1. Review today's Agenda
2. Review 2021-12-13 Pump Zoom Session
3. Discussion of MDC_FLOW_FLUID_PUMP, MDC_FLOW_FLUID_PUMP_CURRENT, MDC_FLOW_FLUID_PUMP_SETTING
4. Review containment draft for pcd-03
5. Review PCD Device Infusion Pump Action Items
6. New Business / Next Meetings

Attachments / Materials

  • <add attachments links here>
PCD03 containment for discussion

Discussion Notes

Chair/Host: Kurt Elliason (Smiths Medical)
Participants:


NOTE: Action Item Review updates have been posted directly to the Infusion Pump Action Items wiki page


Item Topic Discussion
1 Agenda & Discussion Notes Review
- Chair
Status/Discussion:


Decisions/Issues:


Action(s):

2 MDC_FLOW_FLUID_PUMP
- Chair + Steve Dain
Status/Discussion:
Existing term MDC_FLOW_FLUID_PUMP 26712 (secondary refid as MDC_RATE_INFUS) which is currently defined as "Volume rate delivered by pump" in the 10101:2019 and is defined differently as "Programmed volumetric delivery rate" in latest PCD10 containment spreadsheet
New proposed term MDC_FLOW_FLUID_PUMP_CURRENT code 26942 defined as "current pump fluid flow"
Historically we have used 26712 as the flow of the pump.
Pump WG desired to communicate what the pump rate is set at, even when the pump is not infusing.
We may have created some difficulties with the proposed term and the "new" definition of an old term.
Suggestion is to delete the proposed term MDC_FLOW_FLUID_PUMP_CURRENT, clarifying the definition of MDC_FLOW_FLUID_PUMP 26712 as "current fluid volume rate delivered by the pump"
Create a new term MDC_FLOW_FLUID_PUMP_SETTING with the definition "current fluid volume rate setting" Note: This represents the current set rate with the pump either in standby or infusing


Decisions/Issues:


Action(s):


3 PCD03 Containment
- tbd
Status/Discussion:


Decisions/Issues:


Action(s):


4 Next Meeting
- Chair
Status/Discussion:

Decisions/Issues:

  • Topics will include ...

Action(s):


Next Meeting

NOTE: Next Meeting will be held during the regularly scheduled time: 12:00 (Eastern) on Jan 24 (60 minutes)