Difference between revisions of "PCD Pump 2021-06-14 WebEx"
Jump to navigation
Jump to search
(Created page with "{{TOCright}} (Infusion Pump Main Page) == Meeting Purpose == IHE PCD Infusion Pump Working Group discussions. == WebEx Information == Topic:...") |
|||
(5 intermediate revisions by the same user not shown) | |||
Line 24: | Line 24: | ||
:1. Review today's Agenda | :1. Review today's Agenda | ||
:2. Review [[PCD_Pump_2021-05-24 WebEx | 2021-05-24 Pump WebEx Session]] | :2. Review [[PCD_Pump_2021-05-24 WebEx | 2021-05-24 Pump WebEx Session]] | ||
− | :3. | + | :3. MDCX terms |
− | : | + | :4a. Units of measure (mg of X) |
+ | :4b. Priming Info Channel | ||
:5. Review [[PCD Device Infusion Pump Action Items | PCD Device Infusion Pump Action Items]] | :5. Review [[PCD Device Infusion Pump Action Items | PCD Device Infusion Pump Action Items]] | ||
:6. New Business / Next Meetings | :6. New Business / Next Meetings | ||
Line 32: | Line 33: | ||
:* '''<add attachments links here>''' | :* '''<add attachments links here>''' | ||
+ | :[https://drive.google.com/file/d/1ZCbzjCaVj1TUeE7hW7J2CbNzc3AhS8oI/view?usp=sharing proposed containment model] | ||
+ | :[https://drive.google.com/file/d/1nmV48Vu0tBh-4Q6JT2p6GBGQvyUez1_m/view?usp=sharing pump enums ] | ||
+ | :[https://drive.google.com/file/d/11laciC4eRZhf_oBub8LxJiR2L8jMJFQa/view?usp=sharing PCD03 terms] | ||
== Discussion Notes == | == Discussion Notes == | ||
Line 37: | Line 41: | ||
:'''Chair/Host:''' ''Kurt Elliason (Smiths Medical)'' | :'''Chair/Host:''' ''Kurt Elliason (Smiths Medical)'' | ||
− | :'''Participants:''' '' | + | :'''Participants:''' '' Al Engelbert (BBraun), Andrea Robertson (Smiths), Brian Sullivan(BD), Jeff Rinda (Interoperability Solutions), Marufur Rahmen (ICU), Michael Workman (BD), Paul Schluter (), Tom Kowalczyk (BBraun); |
+ | |||
Line 62: | Line 67: | ||
|- | |- | ||
| align="center" | 2 | | align="center" | 2 | ||
− | | ''' | + | | '''Planned topics''' <br>- tbd |
| '''Status/Discussion:''' | | '''Status/Discussion:''' | ||
+ | ::MDC_VOL_PCA_DOSE_LIMIT is missing from RTMMS. CF_CODE10 was defined along with several others, the ones before and after this one are in RTMMS. Need to find original description and get this one added. | ||
+ | |||
+ | ::Jeff has descriptions for other MDCX terms. | ||
+ | :::MDCX_INFUS_ORDER_STEP_NUM | ||
+ | :::MDCX_INFUS_TOTAL_NUM_STEPS | ||
+ | :::MDCX_INFUS_ORDER_STEP_TYPE - also needs new enum defined _MDC_INFUS_ORDER_STEP_TYPE | ||
+ | :::MDCX_INFUSION_ORDER_TYPE - also needs new enum defined _MDC_INFUS_ORDER_TYPE | ||
+ | |||
+ | ::[https://drive.google.com/file/d/1nmV48Vu0tBh-4Q6JT2p6GBGQvyUez1_m/view?usp=sharing pump enums ] | ||
+ | ::[https://drive.google.com/file/d/11laciC4eRZhf_oBub8LxJiR2L8jMJFQa/view?usp=sharing PCD03 terms] | ||
+ | |||
+ | |||
+ | |||
+ | :Units of measure (mg of X) - did not discuss today | ||
+ | |||
+ | :Priming Info channel | ||
+ | ::Discussed draft proposal. :[https://drive.google.com/file/d/1ZCbzjCaVj1TUeE7hW7J2CbNzc3AhS8oI/view?usp=sharing proposed containment model] how does this info channel interact with data in other channels. | ||
+ | |||
+ | ::If Priming Info channel includes MDC_FLOW_FLUID_PUMP How is this different from MDC_FLOW_FLUID_PUMP_CURRENT in the deliv channel? | ||
+ | ::Might need three new terms | ||
+ | :::MDC_VOL_FLUID_PRIMING | ||
+ | :::MDC_VOL_FLUID_PRIMING_REMAIN | ||
+ | :::MDC_VOL_FLUID_PRIMING_TBI | ||
Line 74: | Line 102: | ||
|- | |- | ||
| align="center" | 3 | | align="center" | 3 | ||
− | | ''' | + | | '''TF Vol 2 question''' <br>- tbd |
| '''Status/Discussion:''' | | '''Status/Discussion:''' | ||
+ | :Need to correct table in TF Vol 2 section 3.3.4.4.10.2 | ||
+ | ::Heading in Col 7 should read | ||
+ | :::OBX segment with OBX-3 = MDCX_INFUSION_ ORDER_TYPE w/OBX-5 = clinician-dose | ||
+ | ::Heading in Col 8 should read | ||
+ | :::OBX segment with OBX-3 = MDC_FLOW_ FLUID_PUMP | ||
+ | |||
+ | :Second bullet in "OBX segment" section near line 1070 should be changed to | ||
+ | ::OBX-3 = MDCX_INFUSION_ORDER_TYPE. This term has enumerations in OBX-5 of “clinician-dose”, “loading-dose”, or “continuous”. | ||
Latest revision as of 12:40, 14 June 2021
Meeting Purpose
IHE PCD Infusion Pump Working Group discussions.
WebEx Information
Topic: IHE PCD Infusion Pump WG
Date: Monday, June 14, 2021
Time: 12:00, Eastern Time (GMT -05:00, New York)
Duration: 60 Minutes
Note: Specific web & phone information will be provided via e-mail to group members.
Contact Kurt Elliason for more information.
Proposed Agenda
- 1. Review today's Agenda
- 2. Review 2021-05-24 Pump WebEx Session
- 3. MDCX terms
- 4a. Units of measure (mg of X)
- 4b. Priming Info Channel
- 5. Review PCD Device Infusion Pump Action Items
- 6. New Business / Next Meetings
Attachments / Materials
- <add attachments links here>
- proposed containment model
- pump enums
- PCD03 terms
Discussion Notes
- Chair/Host: Kurt Elliason (Smiths Medical)
- Participants: Al Engelbert (BBraun), Andrea Robertson (Smiths), Brian Sullivan(BD), Jeff Rinda (Interoperability Solutions), Marufur Rahmen (ICU), Michael Workman (BD), Paul Schluter (), Tom Kowalczyk (BBraun);
- NOTE: Action Item Review updates have been posted directly to the Infusion Pump Action Items wiki page
Item Topic Discussion 1 Agenda & Discussion Notes Review
- ChairStatus/Discussion:
Decisions/Issues:
Action(s):2 Planned topics
- tbdStatus/Discussion: - MDC_VOL_PCA_DOSE_LIMIT is missing from RTMMS. CF_CODE10 was defined along with several others, the ones before and after this one are in RTMMS. Need to find original description and get this one added.
- Jeff has descriptions for other MDCX terms.
- MDCX_INFUS_ORDER_STEP_NUM
- MDCX_INFUS_TOTAL_NUM_STEPS
- MDCX_INFUS_ORDER_STEP_TYPE - also needs new enum defined _MDC_INFUS_ORDER_STEP_TYPE
- MDCX_INFUSION_ORDER_TYPE - also needs new enum defined _MDC_INFUS_ORDER_TYPE
- Jeff has descriptions for other MDCX terms.
- Units of measure (mg of X) - did not discuss today
- Priming Info channel
- Discussed draft proposal. :proposed containment model how does this info channel interact with data in other channels.
- If Priming Info channel includes MDC_FLOW_FLUID_PUMP How is this different from MDC_FLOW_FLUID_PUMP_CURRENT in the deliv channel?
- Might need three new terms
- MDC_VOL_FLUID_PRIMING
- MDC_VOL_FLUID_PRIMING_REMAIN
- MDC_VOL_FLUID_PRIMING_TBI
Decisions/Issues:
Action(s):
3 TF Vol 2 question
- tbdStatus/Discussion: - Need to correct table in TF Vol 2 section 3.3.4.4.10.2
- Heading in Col 7 should read
- OBX segment with OBX-3 = MDCX_INFUSION_ ORDER_TYPE w/OBX-5 = clinician-dose
- Heading in Col 8 should read
- OBX segment with OBX-3 = MDC_FLOW_ FLUID_PUMP
- Heading in Col 7 should read
- Second bullet in "OBX segment" section near line 1070 should be changed to
- OBX-3 = MDCX_INFUSION_ORDER_TYPE. This term has enumerations in OBX-5 of “clinician-dose”, “loading-dose”, or “continuous”.
Decisions/Issues:
Action(s):
4 Next Meeting
- ChairStatus/Discussion: Decisions/Issues:
- Topics will include ...
Action(s):
Next Meeting
NOTE: Next Meeting will be held during the regularly scheduled time: 11:00 (Eastern) on June 28 (60 minutes)
(Reviewed & approved by PCD Infusion Pump WG on <TBD>