Difference between revisions of "PCD Profile Alarm Communication Management"

From IHE Wiki
Jump to navigation Jump to search
(Add links to trial implementation version)
 
(6 intermediate revisions by one other user not shown)
Line 13: Line 13:
 
'''[ftp://ftp.ihe.net//Patient_Care_Devices/TechnicalFrameworkforTrialImplementation/IHE_PCD_TF_Supplement_Alarm_Communication_Management_ACM_TI_2008-08-22.doc Framework Supplement for Trial Implementation 2008-08-22 (MSWord .doc)]
 
'''[ftp://ftp.ihe.net//Patient_Care_Devices/TechnicalFrameworkforTrialImplementation/IHE_PCD_TF_Supplement_Alarm_Communication_Management_ACM_TI_2008-08-22.doc Framework Supplement for Trial Implementation 2008-08-22 (MSWord .doc)]
  
'''[ftp://ftp.ihe.net//Patient_Care_Devices/TechnicalFrameworkforTrialImplementation/TechnicalFrameworkforTrialImplementation/IHE_PCD_TF_Supplement_Alarm_Communication_Management_ACM_TI_2008-08-22.pdf Framework Supplement for Trial Implementation 2008-08-22 (.pdf)]
+
'''[ftp://ftp.ihe.net//Patient_Care_Devices/TechnicalFrameworkforTrialImplementation/IHE_PCD_TF_Supplement_Alarm_Communication_Management_ACM_TI_2008-08-22.pdf Framework Supplement for Trial Implementation 2008-08-22 (.pdf)]
  
  
Line 26: Line 26:
  
 
== Alarm Semantics & State Models ==  
 
== Alarm Semantics & State Models ==  
''<Add: alarm state model (inactive / active / latched + latchable)>''
+
 
 +
The states of a particular alarm condition are modeled as being: off (alarm condition does not currently exist), active (alarm condition currently exists), or latched (alarm condition formerly exists, does not now exist but is 'latched' so that clinicians can be informed of transient but significant conditions). The valid state transitions are diagrammed below.
 +
 
 +
 
 +
[[Image:Top_Level_State_Chart.PNG]]
  
 
''<Add:  analysis of alarm semantics from alarm sources>''
 
''<Add:  analysis of alarm semantics from alarm sources>''
Line 33: Line 37:
 
== Meetings ==
 
== Meetings ==
  
 +
[[PCD_ACM_2009-07-09_Webex | 2009-07-09 Webex]]
 +
 +
== See also ==
 +
 +
=== Google Groups ===
 +
 +
 +
:: [http://groups.google.com/group/ihe-pcd-acm-technical-wg (ACM) IHE PCD Alarm Communication Management Technical Working Group]
 +
 +
:: [http://groups.google.com/group/ihe-pcd-acm-planning-wg (ACM) IHE PCD Alarm Communication Management Planning Working Group]
 +
 +
[[Patient Care Devices|PCD Home]] | [[:Category: PCD Meeting|PCD Recent Meetings Page]] | [[:Category:PCD_Meeting_Archive|PCD Meeting Archive]]
  
[[Category:PCD]]
+
[[Category:PCD]] [[Category:PCD ACM]]  [[Category:PCD Pages Needing Work]]

Latest revision as of 15:33, 16 December 2014

Current Documents

Brief Profile Proposal

Detailed Profile Proposal

Supplement for Public Comment

Drafts of Supplement Prior to Public Comment Version

Framework Supplement for Trial Implementation 2008-08-22 (MSWord .doc)

Framework Supplement for Trial Implementation 2008-08-22 (.pdf)


Documents Containing Comments to the Supplement for Public Comment


ACM Working Documents

Alarm Semantics & State Models

The states of a particular alarm condition are modeled as being: off (alarm condition does not currently exist), active (alarm condition currently exists), or latched (alarm condition formerly exists, does not now exist but is 'latched' so that clinicians can be informed of transient but significant conditions). The valid state transitions are diagrammed below.


Top Level State Chart.PNG

<Add: analysis of alarm semantics from alarm sources>


Meetings

2009-07-09 Webex

See also

Google Groups

(ACM) IHE PCD Alarm Communication Management Technical Working Group
(ACM) IHE PCD Alarm Communication Management Planning Working Group

PCD Home | PCD Recent Meetings Page | PCD Meeting Archive