'''[ftp://ftp.ihe.net//Patient_Care_Devices/Profiles/ACM/ Drafts of Supplement Prior to Public Comment Version] | '''[ftp://ftp.ihe.net//Patient_Care_Devices/Profiles/ACM/ Drafts of Supplement Prior to Public Comment Version] | ||
+ | |||
+ | '''[ftp://ftp.ihe.net//Patient_Care_Devices/TechnicalFrameworkforTrialImplementation/IHE_PCD_TF_Supplement_Alarm_Communication_Management_ACM_TI_2008-08-22.doc Framework Supplement for Trial Implementation 2008-08-22 (MSWord .doc)] | ||
+ | |||
+ | '''[ftp://ftp.ihe.net//Patient_Care_Devices/TechnicalFrameworkforTrialImplementation/IHE_PCD_TF_Supplement_Alarm_Communication_Management_ACM_TI_2008-08-22.pdf Framework Supplement for Trial Implementation 2008-08-22 (.pdf)] | ||
+ | |||
+ | |||
+ | '''Documents Containing Comments to the Supplement for Public Comment''' | ||
Line 19: | Line 26: | ||
== Alarm Semantics & State Models == | == Alarm Semantics & State Models == | ||
− | + | ||
+ | The states of a particular alarm condition are modeled as being: off (alarm condition does not currently exist), active (alarm condition currently exists), or latched (alarm condition formerly exists, does not now exist but is 'latched' so that clinicians can be informed of transient but significant conditions). The valid state transitions are diagrammed below. | ||
+ | |||
+ | |||
+ | [[Image:Top_Level_State_Chart.PNG]] | ||
''<Add: analysis of alarm semantics from alarm sources>'' | ''<Add: analysis of alarm semantics from alarm sources>'' | ||
Line 26: | Line 37: | ||
== Meetings == | == Meetings == | ||
+ | [[PCD_ACM_2009-07-09_Webex | 2009-07-09 Webex]] | ||
+ | |||
+ | == See also == | ||
+ | |||
+ | === Google Groups === | ||
+ | |||
+ | |||
+ | :: [http://groups.google.com/group/ihe-pcd-acm-technical-wg (ACM) IHE PCD Alarm Communication Management Technical Working Group] | ||
+ | |||
+ | :: [http://groups.google.com/group/ihe-pcd-acm-planning-wg (ACM) IHE PCD Alarm Communication Management Planning Working Group] | ||
+ | |||
+ | [[Patient Care Devices|PCD Home]] | [[:Category: PCD Meeting|PCD Recent Meetings Page]] | [[:Category:PCD_Meeting_Archive|PCD Meeting Archive]] | ||
− | [[Category:PCD]] | + | [[Category:PCD]] [[Category:PCD ACM]] [[Category:PCD Pages Needing Work]] |
Latest revision as of 15:33, 16 December 2014
Current Documents
Drafts of Supplement Prior to Public Comment Version
Framework Supplement for Trial Implementation 2008-08-22 (MSWord .doc)
Framework Supplement for Trial Implementation 2008-08-22 (.pdf)
Documents Containing Comments to the Supplement for Public Comment
Alarm Semantics & State Models
The states of a particular alarm condition are modeled as being: off (alarm condition does not currently exist), active (alarm condition currently exists), or latched (alarm condition formerly exists, does not now exist but is 'latched' so that clinicians can be informed of transient but significant conditions). The valid state transitions are diagrammed below.
<Add: analysis of alarm semantics from alarm sources>