PCC Actor Requirements
Jump to navigation
Jump to search
Requirements of {{{1}}} Actors
This section describes the specific requirements for each Actor defined within this profile. Specific details can be found in Volume 1 and Volume 2 of the technical framework.
Content Creator
- A Content Creator shall be grouped with the Time Client Actor, and shall synchronize its clock with a Time Server.
- A Content Creator shall be grouped with the Secure Node or Secure Application Actor of the ATNA profile.
- All activity initiated by the application implementing the Content Creator shall generate the appropriate audit trail messages as specified by the ATNA Profile. The bare minimum requirements of a Content Creator are that it be able to log creation and export of clinical content.
- A Content Creator shall use secure communications for any document exchanges, according to the specifications of the ATNA profile.
Content Consumer
- A Content Consumer shall implement the View Option or Discrete Data import option, or both.
- A Content Consumer that implements the Document Import or Section Import Option shall implement the View Option as well.
- A Content Consumer that implements the View option shall be able to:
- Demonstrate rendering of the document for display.
- Print the document.
- Display the document with its original stylesheet.
- Support traversal of any links contained within the document.
- A Content Consumer that implements the Document Import Option shall:
- Store the document.
- Demonstrate the ability to access the document again from local storage.
- A Content Consumer that implements the Section Import Option shall offer a means to import one or more document sections into the patient record as free text.
- A Content Consumer that implements the Discrete Data Import Option shall offer a means to import structured data from one or more sections of the document.
- A Content Consumer Actor shall be grouped with the Time Client Actor, and shall synchronize its clock with a Time Server.
- All activity initiated by the application implementing the Content Consumer shall generate the appropriate audit trail messages as specified by the ATNA Profile. The bare minimum requirements of a Content Consumer are that it be able to log views or imports of clinical content.
- A Content Consumer shall log events for any views of stored clinical content.
- A Content Consumer shall use secure communications for any document exchanges, according to the specifications of the ATNA profile.