For the purpose of IHE Connectathon testing, we have never “failed” a vendor for its implementation of a IHE profile/actor because of a single error message reported by a tool.
 
For the purpose of IHE Connectathon testing, we have never “failed” a vendor for its implementation of a IHE profile/actor because of a single error message reported by a tool.
  
=Pre-Connectathon Test Status - by Domain=
 
The tables below identify the status of pre-Connectathon tests and which tools are used to test each IHE profile.
 
<br>
 
To locate the tools and documentation, refer to the [http://wiki.ihe.net/index.php?title=IHE_Test_Tool_Information#Index_to_IHE_Test_Tools Index to IHE tools] in the previous section.
 
<br>
 
==Anatomic Pathology==
 
[mailto:eric.poiseau@inria.fr Eric Poiseau] is the Technical Project Manager who oversees testing in this domain.
 
{| style="width:100%" border="1" cellpadding="3"
 
! Profile !! Status of pre-Connectathon tests !! Tool to use / Notes
 
|- style="background-color:pink"
 
|  APW - Anatomic Pathology Workflow
 
|  No tests defined 
 
|  You may use the '''Gazelle External Validation Service''' for HL7 messages specific to this profile
 
|- style="background-color:pink"
 
| ARPH - Anatomic Pathology Reporting to Public Health
 
| No tests defined 
 
|  You may use the '''Gazelle External Validation Service''' for HL7 messages specific to this profile
 
|- style="background-color:pink"
 
|  ARSR - Anatomic Pathology Structured Reports
 
 
|
 
|}
 
 
==Cardiology==
 
There is no Technical Project Manager assigned to the Cardiology domain.
 
{| style="width:100%" border="1" cellpadding="3"
 
! Profile !! Status of pre-Connectathon tests !! Tool to use / Notes
 
|- style="background-color:orange"
 
| CATH - Cardiac Catheterization Workflow
 
| '''TESTS READY'''
 
| Use '''Gazelle External Validation Service''' for HL7 msg & DICOM object validation.  Use '''Patient Manager''' & '''Order Manager''' for ADT, ORM & MWL simulators.
 
|- style="background-color:orange"
 
| CIRC - Cardiac Imaging Report Content
 
|
 
| No test tool.  Test defined to exchange pre-Connectathon samples.
 
|- style="background-color:orange"
 
| CPN - Cardiac Procedure Note
 
|
 
|
 
|- style="background-color:orange"
 
| CRC - Cath Report Content
 
| '''TESTS READY'''
 
| Use '''Gazelle External Validation Service''' for validation of the CDA document
 
|- style="background-color:orange"
 
| DRPT - Displayable Reports
 
|
 
| No test tools.
 
|- style="background-color:orange"
 
| ECHO - Echocardiography Workflow
 
| '''TESTS READY''' 
 
| Use '''Gazelle External Validation Service''' for HL7 msg & DICOM object validation.  Use '''Patient Manager''' & '''Order Manager''' for ADT, ORM & MWL simulators.
 
|- style="background-color:orange"
 
| ECG - Retrieve ECG for Display
 
|
 
| No test tool
 
|- style="background-color:orange"
 
| ED-CARD - Evidence Documents for Cardiology
 
|
 
| No test tool'
 
|- style="background-color:orange"
 
| ED-CARD extensions for Stress Testing and CT/MR Angiography
 
|
 
| No test tool.  Test defined to exchange pre-Connectathon samples.
 
|- style="background-color:orange"
 
| EPRC-IE - Electrophysiology Implan/Explant Report Content
 
|
 
| No test tool.  Test defined to exchange pre-Connectathon samples.
 
|- style="background-color:orange"
 
| IEO - Image-Enabled Office
 
| No tests defined 
 
| No test tools.
 
|- style="background-color:orange"
 
| RCS-C - Registry Content Submission - Cath PCI
 
| '''TESTS READY'''
 
| Use '''Gazelle External Validation Service''' for validation of the CDA document
 
|- style="background-color:orange"
 
| RCS-EP - Registry Content Submission - Electrophysiology
 
|
 
| Use '''Gazelle External Validation Service''' for validation of the CDA document
 
 
|- style="background-color:orange"
 
| REWF - Resting ECG Workflow
 
| Some tests ready
 
| Use '''Gazelle External Validation Service''' for HL7 msg & DICOM object validation.  Use '''Patient Manager''' & '''Order Manager''' for ADT, ORM & MWL simulators. /  Note that these are standard "SWF-style" tests.  No REWF-specific tests provided. 
 
|- style="background-color:orange"
 
| STRESS - Stress Testing Workflow
 
| '''TESTS READY'''
 
| Use '''Gazelle External Validation Service''' for HL7 msg & DICOM object validation.  Use '''Patient Manager''' & '''Order Manager''' for ADT, ORM & MWL simulators.
 
|}
 
 
==Dental==
 
 
No Technical Project Manager in this domain.
 
{| style="width:100%" border="1" cellpadding="3"
 
! Profile !! Status of pre-Connectathon tests !! Tool to use / Notes
 
|- style="background-color:lightgray"
 
|  SEDI - Secure Exchange of Dental Information
 
 
 
|}
 
 
==Eye Care==
 
No Technical Project Manager in this domain.
 
{| style="width:100%" border="1" cellpadding="3"
 
! Profile !! Status of pre-Connectathon tests !! Tool to use / Notes
 
|- style="background-color:salmon"
 
|  ECED - Eye Care Evidence Documents
 
| '''TESTS READY'''
 
| Evidence Creators use '''Gazelle External Validation Service'''  for DICOM object validation.
 
|- style="background-color:salmon"
 
|  ECDR - Eye Care Displayable Reports
 
|
 
| No test tool
 
|- style="background-color:salmon"
 
|  EC-Summary - Eye Care Summary document
 
| No test tools.
 
| We have a pre-Connectathon test for '''Content Creator & Content Consumer actors''' to exchange pre-Connectathon sample documents.
 
|- style="background-color:salmon"
 
|  GEE - General Eye Evaluation
 
| No test tools.
 
| We have a pre-Connectathon test for '''Content Creator & Content Consumer actors''' to exchange pre-Connectathon sample documents.
 
|- style="background-color:salmon"
 
|  U-EYECARE - Unified Eye Care Workflow
 
| '''TESTS READY''' 
 
| '''MOD & AMI actors''' use the '''Gazelle External Validation Service''' for DICOM object validation. Use '''Gazelle Order Manager''' as a Modality Worklist SCP.
 
 
No tools for the new EYECARE HL7 transactions, but pre-Connectathon tests do manual scrutiny of sample messages.
 
|}
 
 
==IT Infrastructure==
 
[mailto:felhofer.lynn@gmail.com Lynn Felhofer] is the Technical Project Manager who oversees testing in this domain.
 
{| style="width:100%" border="1" cellpadding="3"
 
! Profile !! Status of pre-Connectathon tests !! Tool to use / Notes
 
 
|- style="background-color:lightyellow"
 
| APPC - Patient Patient Privacy Consents
 
| '''TESTS READY'''
 
| '''Content Creators''' use the '''Gazelle External Validation Services (EVSClient) - APPC validator'''
 
|- style="background-color:lightyellow"
 
| ATNA - Audit Trail and Node Authentication
 
| '''TESTS READY'''
 
|'''SN & SA actors''':  for TLS testing use  '''Gazelle Security Suite''' to obtain Digital Cert for connectathon testing, and for TLS and ATNA logging testing.
 
 
No tools for '''Retrieve Audit Msg''' or '''Retrieve Syslog Msg''' options
 
|- style="background-color:lightyellow"
 
| BPPC - Basic Patient Privacy Consents
 
| '''TESTS READY'''
 
| '''Content Creators''' use the '''Gazelle External Validation Services (EVSClient) - CDA validator'''
 
|- style="background-color:lightyellow"
 
| CSD - Care Services Discovery
 
|
 
| No test tools; one pre-Connectathon test for '''Directory''' to load CSD test data developed for Connectathon testing.
 
|- style="background-color:lightyellow"
 
| CT - Consistent Time
 
|
 
| No test tools.
 
|- style="background-color:lightyellow"
 
| DEN - Document Encryption
 
|
 
| No test tools, but please refer to helpful guidance for implementers here: https://wiki.ihe.net/index.php/Document_Encryption_-_Implementation_Notes_and_Examples
 
|- style="background-color:lightyellow"
 
| DSG - Document Digital Signature
 
| '''TESTS READY'''
 
| '''Content Creators''' use '''Gazelle External Validation Services (EVSClient)'''
 
|- style="background-color:lightyellow"
 
| DSUB - Document Metadata Subscription
 
| '''TESTS READY'''
 
|  Use  '''Gazelle External Validation Service -- DSUB validator'''
 
 
'''Broker''' actor use '''Gazelle XD* Client''' as ITI-52 and ITI-54 simulator
 
|- style="background-color:lightyellow"
 
| EUA - Enterprise User Authentication
 
|
 
| No test tools.
 
|- style="background-color:lightyellow"
 
| HPD - Healthcare Provider Directory
 
| '''TESTS READY'''
 
| Use the '''Gazelle HPD Simulator (and validator)''' to test ITI-58 and ITI-59
 
|- style="background-color:lightyellow"
 
| IUA - Internet User Authentication
 
|
 
| No test tools.
 
|- style="background-color:lightyellow"
 
| mACM - Mobile Alert Communication Management
 
| '''TEST READY'''
 
| Actors that create or consumer FHIR Resources use '''Gazelle External Validation Services (EVSClient)'''
 
|- style="background-color:lightyellow"
 
| mCSD - Mobile Care Services Discovery
 
| '''TEST READY'''
 
| No test tools; one pre-Connectathon test for '''mCSD''' to load mCSD test data (FHIR Resources) developed for Connectathon testing.
 
|- style="background-color:lightyellow"
 
| MHD - Mobile Access to Health Documents
 
| '''TESTS READY'''
 
| '''Doc Source''' and '''Doc Recipient''': Use '''FHIR Toolkit''' from NIST.
 
 
Actors that create or consume FHIR Resources use '''Gazelle External Validation Services (EVSClient)'''
 
|- style="background-color:lightyellow"
 
| MPQ - Multi-Patient Queries
 
| '''TESTS READY'''
 
| Use the NIST '''XDS Toolkit'''
 
 
Use '''Gazelle XD* Client''' simulator to send ITI-55.
 
 
|- style="background-color:lightyellow"
 
| mXDE - Mobile Cross-Enterprise Document Data Element Extraction
 
| '''TESTS READY'''
 
| Actors that create or consumer FHIR Resources use '''Gazelle External Validation Services (EVSClient)'''
 
|- style="background-color:lightyellow"
 
| NPFSm - Non-Patient File Sharing
 
| '''TESTS READY'''
 
| Actors that create or consumer FHIR Resources use '''Gazelle External Validation Services (EVSClient)'''
 
|- style="background-color:lightyellow"
 
| PAM - Patient Administration Management
 
| '''TESTS READY'''
 
| Use '''Gazelle External Validation Services (EVSClient)''' for HL7 msg validation.
 
 
Use the '''Gazelle Patient Manager''' as a simulator for PAM Patient Demographics Supplier and Consumer.
 
|- style="background-color:lightyellow"
 
| PDQ - Patient Demographics Query
 
| '''TESTS READY'''
 
| Use NIST '''PIX / PDQ tool'''. 
 
 
Use '''Gazelle External Validation Services (EVSClient)''' for HL7v2 msg validation. 
 
 
Also use the '''Gazelle PatientManager''' as a simulator for PDQ Consumer or Supplier.
 
|- style="background-color:lightyellow"
 
| PDQ-V3 - Patient Demographic Query HL7 v3
 
| '''TESTS READY'''
 
| Use NIST '''PIX / PDQ tool'''.  Also use the '''Gazelle PatientManager''' as a simulator for PDQv3 Consumer or Supplier.
 
 
Use '''Gazelle External Validation Services (EVSClient)''' for HL7v3 msg validation.
 
|- style="background-color:lightyellow"
 
| PDQm - Patient Demographic Query for Mobile
 
| '''TEST READY'''
 
| Actors that create or consumer FHIR Resources use '''Gazelle External Validation Services (EVSClient)'''
 
 
Also use the '''Gazelle PatientManager''' as a simulator for PDQm Consumer or Supplier.
 
|- style="background-color:lightyellow"
 
| PIX - Patient Identifier Cross-Referencing
 
| '''TESTS READY'''
 
| Use NIST '''PIX / PDQ tool'''. 
 
 
Use '''Gazelle External Validation Services (EVSClient)''' for HL7v2 msg validation. 
 
 
Use the '''Gazelle Patient Manager''' as a simulator for PIX Manager, Consumer, and Source actors.
 
|- style="background-color:lightyellow"
 
| PIX-V3 - Patient Identifier Cross-Reference HL7 v3
 
| '''TESTS READY'''
 
| Use NIST '''PIX / PDQ tool'''. 
 
 
Use '''Gazelle EVSClient''' for HL7v3 msg validation.
 
|- style="background-color:lightyellow"
 
| PIXm - Patient Identifier Cross-Reference for Mobile
 
| '''TEST READY'''
 
| Actors that create or consumer FHIR Resources use '''Gazelle External Validation Services (EVSClient)'''
 
 
Also use the '''Gazelle PatientManager''' as a simulator for PIXm Consumer or PIXm Manager.
 
|- style="background-color:lightyellow"
 
| PLT - Patient Location Tracking
 
| '''TEST READY'''
 
| No test tools, but PLT actors have a pre-Connectathon test to load HL7 codes needed for peer-to-peer tests.
 
|- style="background-color:lightyellow"
 
| PSA - Patient Synchronized Applications
 
|
 
| No test tools.
 
|- style="background-color:lightyellow"
 
| PWP - Personnel White Pages
 
|
 
| No test tools.
 
|- style="background-color:lightyellow"
 
| RFD - Retrieve Form for Data Capture
 
| '''TESTS READY'''
 
| '''Form Fillers''' use the '''RFD Testing System'''
 
|- style="background-color:lightyellow"
 
| RID - Retrieve Information for Display
 
| '''TESTS READY''' 
 
| Use the '''MESA Tools'''
 
|- style="background-color:lightyellow"
 
| RMD - Remove Metadata and Documents
 
| '''TESTS READY''' 
 
| '''Doc Registry & Repository''' use the NIST '''XDS Toolkit'''
 
|- style="background-color:lightyellow"
 
| RMU - Restricted Metadata Update
 
| '''TESTS READY''' 
 
| '''Update Responder''' use the NIST '''XDS Toolkit'''
 
|- style="background-color:lightyellow"
 
| SeR - Secure Retrieve
 
| '''TESTS READY''' 
 
| Use the '''Gazelle External Validation Services (EVSClient) - Assertion validators'''
 
|- style="background-color:lightyellow"
 
| SVS - Sharing Value Sets
 
| '''TESTS READY'''
 
| Use the '''Gazelle SVS Simulator'''. 
 
 
Also use the '''Gazelle External Validation Service (EVSClient)''' for validation of the SVS messages.
 
|- style="background-color:lightyellow"
 
| XCA - Cross-Community Access
 
| '''TESTS READY'''
 
| Use the NIST '''XDS Toolkit'''
 
 
(Note: no tools for Async options (WS-Addressing based or AS4)
 
|- style="background-color:lightyellow"
 
| XCDR - Cross-Community Document Reliable Interchange
 
|
 
| No test tools
 
|- style="background-color:lightyellow"
 
| XCF - Cross Community Fetch
 
| '''TESTS READY'''
 
| Use the '''Gazelle XD* Client''' XCF simulator for sending XCF ITI-63 messages
 
 
Use the '''Gazelle External Validation Services (EVSClient)''' for ITI-63 request/response msg validation
 
|- style="background-color:lightyellow"
 
| XCPD - Cross-Community Patient Discovery
 
| '''TESTS READY'''
 
| Use the '''Gazelle Patient Manager''' XCPD Simulators for sending/receiving ITI-55 messages. 
 
 
(Note: no tools for Async options (WS-Addressing based or AS4)
 
 
Use the '''Gazelle External Validation Service - HL7v3 msg validator''' to validate ITI-55 and ITI-56 request & response.
 
|- style="background-color:lightyellow"
 
| XDM - Cross-Enterprise Document Media Interchange
 
| '''TESTS READY'''
 
| '''Portable Media Creator''', use the '''XDM validator''' in the Edge Test Tool.
 
|- style="background-color:lightyellow"
 
| XDR - Cross-Enterprise Document Reliable Interchange
 
| '''TESTS READY'''
 
| Use the NIST '''XDS Toolkit'''
 
 
Use '''Gazelle External Validation Services (EVSClient)''' for request/response message validation
 
|- style="background-color:lightyellow"
 
| XDS.b - Cross-Enterprise Document Sharing
 
| '''TESTS READY'''
 
| '''Doc Registry & Repository''' use the NIST '''XDS Toolkit'''
 
 
Use '''Gazelle External Validation Services (EVSClient)''' for request/response message validation
 
|- style="background-color:lightyellow"
 
| XDS-SD - Cross-Enterprise Sharing of Scanned Documents
 
|  '''TESTS READY'''
 
| '''Content Creators''' use  '''Gazelle External Validation Service (EVSClient)''' -- CDA Schematron and PDF/A validation
 
|- style="background-color:lightyellow"
 
| XDW - Cross-Enterprise Document Workflow
 
| '''TESTS READY''' 
 
| '''Content Creators''' use  '''Gazelle External Validation Service (EVSClient) -- XDW validator'''
 
|- style="background-color:lightyellow"
 
| XPID - XAD-PID Change Management
 
| '''TESTS READY''' 
 
| '''PIX Manager''' use '''EVSClient''' or the '''PIX/PDQ Tool''' for ITI-64 validation
 
|- style="background-color:lightyellow"
 
| XUA - Cross-Enterprise User Assertion
 
| '''TESTS READY''' 
 
| X-Service Users, use '''Gazelle External Validation Service (EVSClient) - Assertion validator'''
 
The '''Gazelle XDStar Client''' tool can add XUA tokens to XD* transactions
 
 
Also use '''Gazelle-STS Security Token Service'''
 
|- style="background-color:lightyellow"
 
|}
 
 
==Laboratory==
 
[mailto:eric.poiseau@inria.fr Eric Poiseau] is the Technical Project Manager who oversees testing in this domain.
 
{| style="width:100%" border="1" cellpadding="3"
 
! Profile !! Status of pre-Connectathon tests !! Tool to use / Notes
 
|- style="background-color:aqua"
 
| ILW
 
|
 
|
 
|- style="background-color:aqua"
 
|  LAW
 
| '''TESTS READY'''
 
| Use the '''Order Manager''' and the '''Gazelle External Validation Service''' for HL7V2 message validation. / Refer to  [http://gazelle.ihe.net/content/pre-connectathon-tests/law List] of LAW pre-connectathon tests
 
|- style="background-color:aqua"
 
|  LBL
 
| '''TESTS READY'''
 
| Use '''LBL simulator''', and the ''' Gazelle External Validation Service''' for HL7V2 message validation. / Refer to the [http://gazelle.ihe.net/content/pre-connectathon-tests/lbl List] of LBL pre-connectathon tests.
 
|- style="background-color:aqua"
 
|  LCSD
 
| '''TESTS READY'''
 
| Use the ''' LCSD simulator''', and the '''Gazelle External Validation Service''' for HL7V2 message validation. / Refer to [http://gazelle.ihe.net/content/pre-connectathon-tests/lcsd List] of LCSD pre-connectathon tests 
 
|- style="background-color:aqua"
 
| LDA, LPOCT
 
|
 
| Use '''Gazelle External Evaluation Service''' for HL7V2 message validation.
 
|- style="background-color:aqua"
 
| LTW
 
| '''TESTS READY'''
 
|  Use the '''Gazelle Order Manager''', and the '''Gazelle External Evaluation Service''' for HL7V2 message validation. / Refer to the [http://gazelle.ihe.net/content/pre-connectathon-tests/ltw List] of LTW pre-connectahton tests.
 
|- style="background-color:aqua"
 
| XD-LAB - Sharing Laboratory Reports
 
| '''TESTS READY'''
 
| Use the '''CDA validation tool''' from NIST or the '''Gazelle External Validation Services Client'''. 
 
|}
 
 
==Patient Care Coordination==
 
[mailto:moores@mir.wustl.edu Steve Moore] is the Technical Project Manager who oversees testing in this domain.
 
{| style="width:100%" border="1" cellpadding="3"
 
! Profile !! Comment !! Tools to use / Notes
 
|- style="background-color:lightgreen"
 
| APE - Antepartum Education
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| APHP - Antepartum History and Physical
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| APL - Antepartum Lab
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST to do CDA R2 validation.  No schematron test. 
 
|- style="background-color:lightgreen"
 
| APS - Antepartum Summary
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| CM - Care Management
 
| No tests defined
 
| No tools
 
|- style="background-color:lightgreen"
 
| CTNN - Composite Triage and Nursing Note
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| EDPN - Emergency Department Physician's Note
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| EDR - Emergency Department Referral
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| EHDI-WD - Early Hearing Detection & Intervention Workflow Definition
 
| No tests defined
 
| No tools
 
|- style="background-color:lightgreen"
 
| ENS - eNursing Summary
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| ETS - EMS Transport Summary
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST to do CDA R2 validation.
 
|- style="background-color:lightgreen"
 
| IC - Immunization Content
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| ITS - Interfacility Transport Summary
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST to do CDA R2 validation.  No schematron test. 
 
|- style="background-color:lightgreen"
 
| LDHP - Labor and Delivery History and Physical
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| LDS - Labor and Delivery Summary
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| MDS - Maternal Discharge Summary
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| NDS - Newborn Discharge Summary
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| NN - Nursing Note
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| PPOC - Patient Plan of Care
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| PPVS - Post-partum Visit Summary
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| PW - Perinatal Workflow
 
| No tests defined
 
| No tools
 
|- style="background-color:lightgreen"
 
| QED - Query for Existing Data
 
| '''TESTS READY'''
 
| No tools.  Tests to exchange sample QED queries defined in actor test plans on [http://ihewiki.wustl.edu/wiki/index.php/Pre-Connectathon/MESA_Software MESA Tools Main Page].
 
|- style="background-color:lightgreen"
 
| RCG - Request for Clinical Guidance
 
| No tests defined
 
| No tools
 
|- style="background-color:lightgreen"
 
| RECON - Reconciliation of Diagnoses, Allergies, & Meds
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| TN - Triage Note
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| XBeR-WD - Cross-Enterprise eReferral Workflow Definition
 
| Tests under development
 
| Use '''XDW validator in Gazelle External Validation Service'''
 
|- style="background-color:lightgreen"
 
| XDS-MS - Cross Enterprise Sharing of Medical Summaries
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| XPHR - Exchange of Personal Health Record Content
 
| '''TESTS READY'''
 
| '''Content Creator actors''' use '''CDA validation tool''' from NIST
 
|- style="background-color:lightgreen"
 
| XTB-WD - Cross-Enterprise Tumor Board Workflow Definition
 
| No tests defined
 
| No tools
 
|- style="background-color:lightgreen"
 
| XTHM-WD - Cross-Enterprise TeleHomeMonitoring Workflow Definition
 
| Tests under development
 
| Use '''XDW validator in Gazelle External Validation Service'''
 
|}
 
 
==Patient Care Devices==
 
[mailto:paulrshermancce@gmail.com  Paul Sherman] is the Technical Project Manager who oversees testing in this domain.
 
{| style="width:100%" border="1" cellpadding="3"
 
|- style="background-color:white"
 
! Profile !! Status of pre-Connectathon tests !! Tool to use / Notes
 
 
|- style="background-color:tan"
 
| Pre-Connectathon Tests; RTM conformance is required for all except IDCO and RDQ (see below).
 
| Tests Ready
 
| PCD uses '''NIST PCD Tools''' for most HL7 v2 Pre-Connectathon tests. Links are provided here. 
 
 
If an Isolated Test is available that is the required test. A few tests are at the Instance Test level. In that case, Instance Tests are the type test required. Most Isolated Tests include Instance Testing, and Instance Tests can be used as development tools for most tests.
 
CAUTION: Select the correct URL for the type of test (Isolated or Instance) required for Pre-Connectathon testing – i.e., if an Isolated Test is available that is the required test; Instance Tests are required only if an Isolated Test is not available. The type of test is defined within the Gazelle test.
 
:- Isolated Testing: https://ihe-pcd.nist.gov/pcdtool/#/cb
 
:- Instance Testing: https://ihe-pcd.nist.gov/pcdtool/#/cf 
 
If the required test is an Isolated Test you must remember to post (i.e., commit) the test results within the test tool. For all tests upload the log to Gazelle and indicate Self Verified; comments may be included.
 
 
You can find the list of tests with identification of the type of test at [ftp://ftp.ihe.net/Patient_Care_Devices/ConnectathonsIncludingProcessAndTesting/YR14-2020%20North%20American%20Connectathon%20Tests/ PCD Connectathon ftp site].
 
 
|- style="background-color:tan"
 
| DEC - Device Enterprise Communication
 
| Tests Ready
 
| Gazelle and NIST will provide tests appropriate to the actor you have selected. There are 3 options: SPD, POI, WCM.
 
 
|- style="background-color:tan"
 
| ACM - Alarm Communication Management
 
| Tests Ready
 
| Gazelle and NIST will provide tests appropriate to the actor you have selected. There is one option: WCM.
 
 
|- style="background-color:tan"
 
| IDCO - Implantable Device Cardiac Observation
 
| Tests Ready
 
| Gazelle and NIST will provide tests appropriate to the actor you have selected.
 
 
|- style="background-color:tan"
 
| IPEC - Infusion Pump Event Communication
 
| Tests Ready
 
| Gazelle and NIST will provide tests appropriate to the actor you have selected.
 
 
|- style="background-color:tan"
 
| PIV - Point-of-Care Infusion Verification
 
| Tests Ready
 
| Gazelle and NIST will provide tests appropriate to the actor you have selected.
 
 
|- style="background-color:tan"
 
| RDQ - Retrospective Data Query
 
| Tests Ready
 
| Gazelle and NIST will provide tests appropriate to the actor you have selected.
 
 
|- style="background-color:tan"
 
| RTM - Rosetta Terminology Mapping
 
| Tests Ready
 
| All PCD Profiles except IDCO and RDQ require conformance with RTM. Versions are available at [http://wiki.ihe.net/index.php?title=PCD_Profile_Rosetta_Terminology_Mapping]
 
 
|- style="background-color:tan"
 
| WCM - Waveform Communication.
 
| Tests Ready
 
| Gazelle and NIST will provide tests appropriate to the actor you have selected.
 
 
|- style="background-color:tan"
 
| MEMDMC - Medical Device Management Device Management Communication
 
| Tests Ready
 
| Gazelle and NIST will provide tests appropriate to the actor you have selected.
 
 
|- style="background-color:tan"
 
| MEMDLS - Medical Device Management Location Services
 
| Tests Ready
 
| Gazelle and NIST will provide tests appropriate to the actor you have selected.
 
|}
 
 
== Pharmacy ==
 
[mailto:eric.poiseau@inria.fr Eric Poiseau] is the Technical Project Manager who oversees testing in this domain.
 
{| style="width:100%" border="1" cellpadding="3"
 
! Profile !! Status of pre-Connectathon tests !! Tool to use / Notes
 
|- style="background-color:salmon"
 
| CMPD - Community Medication Prescription and Dispense
 
|
 
|
 
|- style="background-color:salmon"
 
| DIS - Pharmacy Dispense
 
|
 
| Use '''Gazelle External Validation Service''' for CDA document validation.
 
|- style="background-color:salmon"
 
| HMW - Hospital Medication Workflow
 
|
 
| Use the ''' HMW simulator'''. Use '''Gazelle External Validation Service''' for HL7V2 message validation.
 
|- style="background-color:salmon"
 
| PADV - Pharmaceutical Advice
 
|
 
| Use '''Gazelle External Validation Service''' for CDA document validation.
 
|- style="background-color:salmon"
 
| PRE - Pharmacy Prescription
 
|
 
| Use '''Gazelle External Validation Service''' for CDA document validation.
 
|- style="background-color:salmon"
 
|}
 
 
==Quality, Research, Public Health==
 
[mailto:moores@mir.wustl.edu Steve Moore] is the Technical Project Manager who oversees testing in this domain.
 
{| style="width:100%" border="1" cellpadding="3"
 
! Profile !! Status of pre-Connectathon tests !! Tool to use / Notes
 
|- style="background-color:yellow"
 
| ADX - Aggregate Data Exchange
 
| '''TEST READY'''
 
|  '''Content Data Structure Creator''' actor use the '''Gazelle External Validation Services (EVS client) - IHE - SDMX'''
 
|- style="background-color:yellow"
 
| BFDR-E - Birth & Fetal Death Reporting -Enhanced
 
| '''TESTS READY'''
 
| '''Form Filler, Form Mgr, Form Processor''' actors use the '''RFD Testing System'''
 
|- style="background-color:yellow"
 
| CRD - Clinical Research Document
 
| '''TESTS READY'''
 
| '''Form Filler''' actors use the '''Gazelle External Validation Services (EVS client) - CDA validator'''
 
|- style="background-color:yellow"
 
| CRPC - Clinical Research Process Content
 
|
 
| No test tool
 
|- style="background-color:yellow"
 
| DEX - Data Element Exchange
 
|
 
| No test tool
 
|- style="background-color:yellow"
 
| DSC - Drug Safety Content
 
|
 
| No test tool
 
|- style="background-color:yellow"
 
| EHDI - Early Hearing Detection & Intervention
 
|
 
| No test tool
 
|- style="background-color:yellow"
 
| EHDI-WD - Early Hearing Detection & Intervention Workflow Definintion
 
|
 
| No test tool
 
|
 
|- style="background-color:yellow"
 
| FP - Family Planning
 
|
 
|
 
|- style="background-color:yellow"
 
| HW - Healthy Weight
 
| '''TESTS READY'''
 
| '''Info Source''' and '''Form Receiver Msg Exporter''' actors use '''NIST HL7 v2.x Message Validation Tool'''
 
|- style="background-color:yellow"
 
| NANI - Newborn Admission Notification Information
 
|
 
| No test tool
 
|- style="background-color:yellow"
 
| PRPH-Ca - Physician Reporting to a Public Health Repository - Cancer Registry
 
| '''TESTS READY'''
 
| '''Content Creator''' actors use the '''Gazelle External Validation Services (EVS client) - CDA validator'''
 
|- style="background-color:yellow"
 
|QME-EH - Quality Measure Execution - Early Hearing
 
|
 
| No test tool
 
|- style="background-color:yellow"
 
| RM - Research Mapping
 
|
 
| No test tool
 
|- style="background-color:yellow"
 
| RPE - Retrieve Protocol for Execution
 
|
 
| No test tool
 
|- style="background-color:yellow"
 
| RSP - Redaction Services
 
|
 
| No test tool
 
|- style="background-color:yellow"
 
| SDC - Structured Data Capture
 
|
 
| No test tool
 
|- style="background-color:yellow"
 
| VRDR - Vital Records Death Reporting
 
| '''TESTS READY'''
 
| '''Form Filler, Form Mgr, Form Processor''' actors use the '''RFD Testing System'''
 
 
'''Information Source''' and '''Form Rcvr Msg Exporter''' actors use the '''Vital Records Validation tool''' from NIST
 
|}
 
 
==Radiology==
 
[mailto:felhofer.lynn@gmail.com Lynn Felhofer] is the Technical Project Manager who oversees testing in this domain.
 
 
{| style="width:100%" border="1" cellpadding="3"
 
! Profile !! Status of pre-Connectathon tests !! Tool to use / Notes
 
|- style="background-color:lightblue"
 
| AIR - AI Results
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| ARI - Access to Radiology Information
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| BIR - Basic Image Review (incl. BIR viewer on PDI media)
 
| '''TESTS READY'''
 
|  No test tools.  '''Image Display''' see test plan at [https://wiki.ihe.net/index.php/Image_Display_Tests#Test_Case_4700:_BIR_Connectathon_tests this link]
 
|- style="background-color:lightblue"
 
| CDS-OAT - Clinical Decision Support - Order Appropriateness Tracking
 
| '''TESTS READY'''
 
| No CDS-OAT-specific tools.  '''Order Placer''' and '''Order Filler''' use '''Gazelle External Validation Service (EVSClient)''' to evaluate base requirements for RAD-2, 3, 4
 
|- style="background-color:lightblue"
 
| CHG - Charge Posting
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| CPI - Consistent Presentation of Images
 
| '''TESTS READY'''
 
| Use '''DICOMScope'''
 
|- style="background-color:lightblue"
 
| CXCAD - Presentation of Chest CAD SR
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| DBT - Digital Breast Tomosynthesis
 
 
| No test tools specific to DBT.  Tests defined for '''MOD''', '''Img Display''' & '''Img Mgr''' to exchange pre-connectathon samples & validate DICOM objects.
 
|- style="background-color:lightblue"
 
| DIFF - MR Diffusion Imaging
 
|
 
| No test tools specific to DIFF.  Tests defined for '''MOD''', '''Img Display''' & '''Img Mgr''' to exchange pre-connectathon samples & validate DICOM objects.
 
|- style="background-color:lightblue"
 
| EBIW - Encounter-based Imaging Workflow
 
 
| No test tool
 
|- style="background-color:lightblue"
 
| ED - Evidence Documents
 
|
 
| No test tools specific to ED.  Tests defined for '''MOD''', '''Img Display''' & '''Img Mgr''' to exchange pre-connectathon samples & validate DICOM objects.
 
|- style="background-color:lightblue"
 
| FUS - Image Fusion
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| IID - Invoke Image Display
 
 
| No test tool; one pre-Connectathon test for '''Image Display''' to load test data to use for Connectathon testing.
 
|- style="background-color:lightblue"
 
| IOCM - Image Object Change Management
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| IDPE - Import & Display of External Priors
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| IRWF.b - Import Reconciliation Workflow
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| KIN - Key Image Note
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| MAMMO - Mammography Image
 
| '''TESTS READY'''
 
| No test tools.  '''Image Display''' see test plan at [https://wiki.ihe.net/index.php/MESA/Image_Display_Mammo this link]
 
|- style="background-color:lightblue"
 
| MAP - Management of Acquisition Protocols
 
|
 
| No test tools.
 
 
|- style="background-color:lightblue"
 
| MAWF - Mammography Acquisition Workflow
 
|
 
| No test tools specific to MAWF.  Tests defined for '''MOD''', '''Img Display''' & '''Img Mgr''' to exchange pre-connectathon samples & validate DICOM objects.
 
|- style="background-color:lightblue"
 
| MRRT - Management of Radiology Reporting Templates
 
 
| No test tool'
 
|- style="background-color:lightblue"
 
| NMI - Nuclear Medicine Image
 
| '''TESTS READY'''
 
| No test tools.  '''Image Display''' see test plan at [https://wiki.ihe.net/index.php/Image_Display_Tests#Nuclear_Medicine_Profile_Tests this link]
 
|- style="background-color:lightblue"
 
| PAWF - Post-Acquisition Workflow
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| PDI - Portable Data for Imaging
 
| '''TESTS READY'''
 
| '''Portable Media Creator actor''' use '''PDI Media Tester application'''
 
|- style="background-color:lightblue"
 
| PERF - CT/MR Perfusion Imaging with Contrast
 
|
 
| No test tool specific to PERF.  Tests defined for '''MOD''', '''Img Display''' & '''Img Mgr''' to exchange pre-connectathon samples & validate DICOM objects.
 
|- style="background-color:lightblue"
 
| PGP - Presentation of Grouped Procedures
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| PIR - Patient Information Reconciliation
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| RD - Results Distribution
 
|
 
| no test tool
 
|- style="background-color:lightblue"
 
| REM - Radiation Exposure Monitoring
 
| '''TESTS READY'''
 
| '''MOD''' actor use '''REM PixelMed DoseUtility'''
 
|- style="background-color:lightblue"
 
| REM-NM - Radiation Exposure Monitoring for Nuclear Medican
 
| '''TESTS READY'''
 
| '''MOD''' actor use '''REM PixelMed DoseUtility'''
 
|- style="background-color:lightblue"
 
| RWF - Reporting Workflow
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| SINR - Simple Image and Numeric Report
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| SMI - Stereotactic Mammography Image
 
|
 
| No test tool specific to SMI.  Tests defined for '''MOD''', '''Img Display''' & '''Img Mgr''' to exchange pre-connectathon samples & validate DICOM objects.
 
|- style="background-color:lightblue"
 
| SOLE - Standardized Operational Log of Events
 
|  '''TESTS READY'''
 
| Use '''Gazelle Security Suite''' to validate log event contents and send them to the Syslog Collector
 
|- style="background-color:lightblue"
 
| SWF - Scheduled Workflow
 
| '''TESTS READY'''
 
| '''MOD actor''' use the '''Gazelle External Validation Service''' for DICOM object validation.  Use '''Gazelle Order Manager''' as a Modality Worklist SCP.  (Note: MESA Tools are now retired.)
 
 
'''ADT, OP and OF actors''' use the '''Gazelle External Validation Service''' to check the HL7 messages you send.
 
 
'''OP, OF actors''', use '''Gazelle Patient Manager''' as an ADT simulator to send RAD-1 and RAD-12 messages.  Use '''Gazelle Order Manager''' as a simulator to send ORM messages, RAD-2, RAD-3. (Note: MESA Tools are now retired.)
 
 
'''Img Mgr actor''' use Order Manager as a simulator to send RAD-4 and RAD-13.  (Note: MESA Tools are now retired.)
 
 
No tools for Image Display & PPSM actors.
 
|- style="background-color:lightblue"
 
| SWF.b - Scheduled Workflow.b
 
| '''TESTS READY'''
 
| '''MOD actor''' use the '''Gazelle External Validation Service''' for DICOM object validation.  Use '''Gazelle Order Manager''' as a Modality Worklist SCP.  (Note: MESA Tools are now retired.)
 
 
'''ADT, OP and OF actors''' use '''Gazelle Patient Manager''' as an ADT simulator to send RAD-1 and RAD-12 messages. Use the '''Gazelle External Validation Service''' to check the HL7 messages you send.
 
 
'''OP, OF actors''' use '''Order Manager''' as a simulator for HL7v2.5.1 order msgs: RAD-2, RAD-3.  (Note: MESA Tools are now retired.)
 
 
'''IM actor''' use '''Order Manager''' as a simulator for HL7v2.5.1 order msgs: RAD-4, RAD-13.  (Note: MESA Tools are now retired
 
 
No tools for Image Display & PPSM actors.
 
|- style="background-color:lightblue"
 
| SWF & PIR - as updated in the Multiple Image Manager/Archive (MIMA) TI Supplement
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| TCE - Teaching FIle and Clinical Trial Export
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| WIA - Web-based Image Access
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| WIC - Web-based Image Capture
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| XCA-I - Cross Community Access for Imaging
 
| '''TESTS READY'''
 
| '''Init Img GW''' and '''Resp Img GW''' use '''XDS Toolkit v7.x.x'''
 
 
Also, use the '''Gazelle XD* client''' for sending RAD-69 and RAD-75 messages. 
 
|- style="background-color:lightblue"
 
| XDR-I - Cross-enterprise Document Reliable Interchange for Imaging
 
|
 
| No test tool
 
|- style="background-color:lightblue"
 
| XDS-I.b - Cross-enterprise Document Sharing for Imaging
 
| '''TESTS READY'''
 
| '''Img Doc Source''' use '''XDS Toolkit v7.x.x''' (or later release)
 
 
Also, use the '''Gazelle XD* client''' for sending RAD-68, -69, -55 messages, and the '''Gazelle External Validation Service - WADO validator'''
 
|}
 
 
* [https://docs.google.com/spreadsheets/d/1J6vlKJE4UbWzqlfRiMmIt0Kb14kPR8r52YL6Xfw7QzQ/edit?usp=sharing PCHA CTT]
 
  
  
 
[[Testing and Tools Committee]]
 
[[Testing and Tools Committee]]

Revision as of 14:21, 8 April 2022

Overview

This page contains information about test tools available for testing IHE Profiles. Several organization contribute to this set of tools; thus, the tools currently reside in different locations and have a variety of support models (jira, email lists). Not all IHE profiles have test tools. This can be a challenge for new implementers, but it is the current state of affairs.

These tools are commonly used in the context of an IHE Connectathon. In that case, the test management tool called 'Gazelle' gives you a customized list of tests to do based on the IHE profiles you support. The tools referenced on this page can be used outside of a Connectathon, but the information on this page assumes that Gazelle is helping to manage testing.

Index to IHE Test Tools

This table lists the tools available for testing IHE profiles, along with links to the tool & documentation.
To determine which tool to use for the profile you want to test, please refer to the domain-specific Index to Pre-Connectathon Tests in the next section.

Tool Developed by Type Tool Location / Installation User documentation & Training Ready to use? Support Used for
CDA Validation tool NIST web-based or download CDA Validation Tool CDA Tool home page Yes CDA Validator contact PCC: all CDA-based profiles except APE, TRS, ETS, ITS
DICOM Central Archive J4CARE web-based Central Archive @ IHE-E Yes
DICOMscope CPI Visualization tools OFFIS install/run locally DICOMScope - IHE Display Consistency distribution page

Or, DICOMScope v. 3.6.4 for 64-bit Windows

DICOMscope overview page Yes https://forum.dcmtk.org/ RAD: CPI
DVTk DICOM validator Philips, ICT access via External Validation Service Front-End, IHE-->DICOM DVTk training & documentation Yes DVTk forum various DICOM-based profiles
Edge Test Tool HealthIT.gov web-based ETT Validators Documentation Yes Help ITI: XDM
FHIR toolkit (MHD / Asbestos) v4.x.x NIST install/run locally Toolkit download Installation Guide Yes MHD implementors google group ITI: MHD
Gazelle CDA Generator IHE-Europe at Kereval web-based CDA Generator CDA Generator info page Yes
Gazelle External Validation Services (EVS) aka "EVSClient" IHE-Europe at Kereval web-based External Validation Service Front-End Gazelle External Validation Services user guide Yes submit issues & questions to our Jira issue tracker AP: APW, ARPH

CARD: CATH, ECHO, REWF, STRESS, CRC, RCS-C

ITI: many; see here

LAB: LAW, LBL, LCSD, LDA, LPOCT, LTW

PCC: XBeR, XTHM

PHARM: DIS, HMW, PADV, PRE, CMPD-WD

QRPH: ADX

RAD: XDS-I.b (Wado)

Gazelle DSUB validator IHE-Europe at Kereval web-based access via External Validation Service Front-End, IHE-->DSUB DSUB validator info page Yes ITI: DSUB
Gazelle HPD validator & simulator IHE-Europe at Kereval web-based access via External Validation Service Front-End, IHE-->Healthcare Provider Directory

HPD Simulator

HPD simulator info page Yes submit issues & questions to our Jira issue tracker ITI: HPD
Gazelle HL7 validator IHE-Europe at Kereval web-based Gazelle HL7 validator HL7 validator info Yes submit issues & questions to our Jira issue tracker many
Gazelle HMW simulator IHE-Europe at Kereval web-based HMW Simulator HMW simulator user guide Yes submit issues & questions to our Jira issue tracker PHARM: HMW
Gazelle LBL simulator IHE-Europe at Kereval web-based LBL simulator LBL simulator user guide Yes submit issues & questions to our Jira issue tracker LAB: LBL
Gazelle LCSD simulator IHE-Europe at Kereval web-based LCSD Simulator LCSD simulator user guide Yes submit issues & questions to our Jira issue tracker LAB: LCSD
Gazelle Order Manager simulator IHE-Europe at Kereval web-based Order Manager application Order Manager user guide Yes submit issues & questions to our Jira issue tracker RAD, EYE, CARD: HL7 orders & DICOM MWL

LAB: LTW, LAW

Gazelle PatientManager - PAM, XCPD, PIX* & PDQ* (HL7v2, v3, FHIR STU3), ADT simulator IHE-Europe at Kereval web-based Patient Manager application user guide Yes submit issues & questions to our Jira issue tracker ITI: PAM, XCPD, PDQ*, PIX*, PDS for XDS

RAD, EYE, CARD: ADT actor

Gazelle Proxy IHE-Europe at Kereval web-based Gazelle proxy Proxy user guide Yes submit issues & questions to our Jira issue tracker proxy for non-TLS msgs
Gazelle Security Suite (gss) IHE-Europe at Kereval web-based http://gazelle.ihe.net/gss ATNA pre-CAT test cases

User Guide

Yes submit issues & questions to our jira issue tracker ITI: ATNA

RAD: SOLE

Gazelle-STS SecurityToken Service (SAML) IHE-Europe at Kereval web-based Service URL pre-CAT test case

User Guide

Yes https://gazelle.ihe.net/jira/projects/STS/issues/STS-7?filter=allopenissues Jira issue tracker] ITI: XUA, IUA (w/ SAML)
Gazelle SVS simulator & validator IHE-Europe at Kereval web-based Gazelle Sharing Value Set Simulator

access SVS msg validator via External Validation Service Front End, IHE--Sharing Value Sets

SVS Simulator user guide

Value sets provided by the SVS Simulator

Yes submit issues & questions to our Jira issue tracker ITI: SVS
Gazelle WADO validator IHE-Europe at Kereval web-based access via External Validation Service Front-End, IHE-->Wado WADO validator info page Yes RAD: XDS-I.b
Gazelle XD* (XD Star) Client Application IHE-Europe at Kereval web-based Gazelle XD* Client Application Introduction to XDStarClient Yes submit issues & questions to our Jira issue tracker ITI: servers in XDS, XDR, XCA, MPQ, DSUB, XCPD, XCF

RAD: XDS-I, XCA-I

Gazelle XDW validator IHE-Europe at Kereval web-based access via External Validation Service Front-End, IHE-->XDW XDW validation service info page Yes ITI: XDW

PCC: XBer-WD,XTHM-WD

Gazelle XUA assertion validator IHE-Europe at Kereval web-based access via External Validation Service Front-End, IHE-->Assertions Assertion validator info page Yes submit issues & questions to our Jira issue tracker ITI: XUA
HL7 v2.x Msg ValidationTool NIST NIST HL7v2.x Msg Validation Tool Documentation Yes Contact us QRPH: VRDR (2015), HW (2015)
MESA Tools MIR RETIRED as of Oct-2019 Actor test plans (Note: These contain test cases that are still used w/o MESA tools.)
MRRT tool MIR RETIRED as of Oct-2019
PCD Isolated & Instance testing NIST web-based IHE-PCD Pre-Connectathon Test Tool IHE-PCD Pre-Connectathon tool home page Yes NIST support team and join PCD testing google group PCD: all profiles
PDI Media Tester application Northwestern install/run locally Test Cases and tool Yes RAD: PDI
PIX / PDQ tool NIST web-based IHE PIX and PDQ Pre-Connectathon Test Tool PIX / PDQ Tool documentation Yes IHE PIX/PDQ google group ITI: PDQ, PDQv3, PIX, PIXv3, XPID
REM DoseUtility tool PixelMed web-based or install locally access via External Validation Service Front-End, IHE-->DICOM how to use DoseUtility Yes RAD: REM
RFD Testing System MIR RETIRED as of Oct-2019
RO Test Tool 2007 DVTk download access via DVTk download page Yes IHE-RO
Vital Records Tool NIST web-based access via NIST VR Validation Tool VR Tool Presentation Yes website admin QRPH: VRDR HL7v2
XDS Public Registry Server (v4.x.x) NIST RETIRED as of May-2018
XDS toolkit v7.x.x NIST install/run locally XDS Toolkit download XDS Toolkit Release notes

Documentation

Yes XDS implementors google group ITI: XDS.b, XDR, XCA, MPQ, RMD, RMU

RAD: XDS-I.b, XCA-I

XUA Security Token Service (STS) Kereval web-based STS info page service URL Yes submit issues & questions to our Jira issue tracker ITI: XUA, IUA w/ SAML



What if a test reports a problem in my software?

The IHE tools are intended to test compliance with specifications in the IHE Technical Frameworks.

When a tool logs an error, it is reporting a difference between a message produced by a vendor application and the tool developer’s interpretation of the requirements in the Technical Framework.

So, a typical reaction by an implementer to an error reported by a tool is one of:

  • “Oh wow, I have a gap in my implementation. I can now fix it so that my message is compliant with the requirements in the IHE Technical Framework.”
  • “The tool reported this error, but I think my implementation is correct.” In that case, you should report the error. We will make an assessment of the tool vs. the specification and will happily fix the tool as needed.
  • “The tool reported an error, but for ‘X’ reason (product-specific, deployment-scenario-specific…), I will not change my implementation to be 100% IHE-compliant for this message."

A given tool rarely, if ever, provides 100% coverage in evaluating an implementation vs. IHE Technical Framework requirements. For some IHE profiles, there is more than one tool, each providing different coverage.

In the context of a Connectathon, IHE promotes a combination of compliance testing between your implementation and a tool **and** face-to-face interoperabity testing between vendors at IHE Connectathons. We believe that combination helps implementers both shake out bugs in their implementation and also demonstrate their ability to interoperate with other vendors based on specifications in IHE Profiles.

IHE Technical Project Managers who have overseen testing at NA and EU IHE Connectathons for many years have heard more than once developers describe the built-in “if Connectathon” switch in their software -- the ability to "turn on" certain capabilities to satisfy a tool or Connectathon test. We cringe every time. If your software fails a tool-based test or peer-to-peer test, you should do the assessment in the bullet list above. In this email thread, John Moehrke (ITI Tech Cmte) provides an example in the context of an audit message.

For the purpose of IHE Connectathon testing, we have never “failed” a vendor for its implementation of a IHE profile/actor because of a single error message reported by a tool.


Testing and Tools Committee