This profile provides an HL7 CDA Implementation Guide for an Electrophysiology Implant/Explant Procedure Report, derived from the Procedure Note specifications as defined in the IHE Health Story Consolidation, Release 1. The content is based on the ACC NCDR ICD Registry version 1.2 data set. | This profile provides an HL7 CDA Implementation Guide for an Electrophysiology Implant/Explant Procedure Report, derived from the Procedure Note specifications as defined in the IHE Health Story Consolidation, Release 1. The content is based on the ACC NCDR ICD Registry version 1.2 data set. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
==Systems Affected== | ==Systems Affected== |
Revision as of 12:22, 21 July 2017
Summary
This profile specifies the content structure for a clinical report of an electrophysiology procedure recorded in an EP Lab. Such procedures include Implantable Cardioverter Defibrillator (ICD) Implant, Permanent Pacemaker (PPM)/Implantable Pulse Generator (IPG) Implant, Implantable Cardiac Monitor Implant, Lead Implant, ICD Explant, Generator Change, Lead Explant, Lead Abandonment, and Imaging associated with Implant/Explant (e.g., Venogram).
Benefits
<If the profile can improve Cost, Safety, Quality or Efficiency then list the specific examples of that benefit (e.g. error reduction, increased throughput) and how they come about (e.g. SWF reduces patient errors due to mistyped demographics at the modality by transfering demographics electronically from the Order Filler). Consider using a bullet list for readability. Such benefits help users and vendors make the business case for the profile. If the profile does not improve any aspect of Cost, Safety, Quality or Efficiency feel free to talk about something else here.>
Details
This profile provides an HL7 CDA Implementation Guide for an Electrophysiology Implant/Explant Procedure Report, derived from the Procedure Note specifications as defined in the IHE Health Story Consolidation, Release 1. The content is based on the ACC NCDR ICD Registry version 1.2 data set.
Systems Affected
The EPRC profile is a content profile, which defines the content of a Cardiac Electrophysiology Report. The means of interchanging the report is not detailed in this profile but addressed in other profiles like DRPT, XDS or PDI. In general two types of systems would be relevant: A reporting workstation, Cardiovascular Information System or an EP Analysis workstation which creates a report and distributes it via one of the mechanism mentioned above. A workstation or system which is receiving and displaying the report. This could be an EMR/EHR System or any type of reporting workstation.
Actors & Transactions:
Specification
Profile Status: Trial Implementation
Documents:
Underlying Standards:
- HL7 CDA Release 2.0
- HL7 Implementation Guide for CDA® Release 2: IHE Health Story Consolidation, Release 1
See Also
Related Profiles
As a content integration profile EPRC provides the payload for any of the exchange mechanisms of the following profiles
- Displayable Reports (DRPT) for the creation, exchange and management of cardiac imaging reports within an enterprise
- Portable Data for Imaging (PDI) for storage and exchange of cardiac imaging Reports on exchangeable media
- Cross Enterprise Document Sharing (XDS) for storage and retrieval of cardiac imaging reports in a cross enterprise setting