DEV Technical Framework

From IHE Wiki
Jump to navigation Jump to search

Overview

DEV TF Transition

  • With the 2019 domain name change from IHE Patient Care Devices (PCD) to simply Devices (DEV), the domain charter and organization also changed to incorporate a broader concept of integration profiles that include "health devices", and not the previously narrower focus on integration scenarios that include at least one "regulated medical device". This version of the IHE DEV TF page reflects the 2020 transition to this broader charter, still in process.
  • The 2020 Edition (10.0) of the IHE DEV Technical Framework (TF) will be updated to reflect both the name change, and more importantly the latest IHE International TF template (also updated early 2020). This page will be updated once the 2020 DEV TF is published later in the year.

PCD TF References

The IHE PCD Technical Framework is composed of a set of profiles that address specific integration scenarios that include at least one regulated medical device (per the PCD Charter).
* Vol. 1 (PCD TF-1): Integration Profiles
* Vol. 2 (PCD TF-2): Transactions
* Vol. 3 (PCD TF-3): Semantic Content

Current Framework Status

Links to current versions of all volumes of the IHE DEV Technical Framework, and current IHE DEV Framework Supplements, may be found at: 

DEV Technical Frameworks listing on ihe.net

DEV Transaction Map

Many of the DEV Profiles include transactions, specified in the Technical Framework Volume 2 Transactions, which are allocated on a domain basis.

Note: That the table indicates not only the DEV-x transaction labels, but for the PCD-x transactions that are from the pre-DEV technical framework versions (1.0 to 9.0), a 2nd column is added to maintain those aliased transaction identifiers as well.

This table identifies the currently allocated transactions and the profiles to which they belong:

ID PCD ID Transaction Title Profile Source Actor Receiving Actor Notes
DEV-01 PCD-01 Communicate PCD Data DEC Device Observation Reporter (DOR) Device Observation Consumer (DOC)
DEV-02 PCD-02 Subscribe to PCD Data SPD Device Observation Consumer (DOC) Device Observation Filter (DOF)
DEV-03 PCD-03 Communicate Infusion Order PIV Infusion Order Programmer (IOP) Infusion Order Consumer (IOC)
DEV-04 PCD-04 Report Alert (Alarm) ACM Alert (Alarm) Reporter (AR) Alert (Alarm) Manager (AM) Formerly ACM-01
DEV-05 PCD-05 Report Alert (Alarm) Status ACM Alert (Alarm) Manager (AM) Alert (Alarm) Reporter (AR) Formerly ACM-02
DEV-06 PCD-06 Disseminate Alert (Alarm) ACM Alert (Alarm) Manager (AM) Alert (Alarm) Communicator (AC) Formerly ACM-03
DEV-07 PCD-07 Report Dissemination Alert (Alarm) Status ACM Alert (Alarm) Communicator (AC) Alert (Alarm) Manager (AM) Formerly ACM-04
DEV-08 PCD-08 (Reserved) ACM      
DEV-09 PCD-09 Communicate IDC Observation IDCO Device Observation Reporter (DOR) Device Observation Consumer (DOC) IDC WG Web Page
DEV-10 PCD-10 Communicate Infusion Pump Event IPEC Device Observation Reporter (DOR) Device Observation Consumer (DOC)  
DEV-11 PCD-11 (Reserved) ACM      
DEV-12 PCD-12 Retrospective Data Query RDQ Retrospective Data Consumer (RDC) Retrospective Data Reporter(RDR)  
DEV-13 PCD-13 Retrospective Data Reply RDQ Retrospective Data Reporter(RDR) Retrospective Data Consumer (RDC)  
DEV-14 PCD-14 (Reserved)        
DEV-15 PCD-15 Device Management Information Observation (DMIO) MEMDMC Device Management Information Reporter (DMIR) Device Management Information Consumer (DMIC)  
DEV-16 PCD-16 Report Location Observation (RLO) MEMLS Location Observation Reporter (LOR) Location Observation Consumer (LOC)  
DEV-17 PCD-17 Assert Device-Patient Association PCIM Device-Patient Association Reporter (DPAR) Device-Patient Association Manager (DPAM) Deprecated, use DEV-51;
DEV-18 PCD-18 Assert Device-Patient Disassociation PCIM Device-Patient Association Reporter (DPAR) Device-Patient Association Manager (DPAM) Deprecated, use DEV-51;
DEV-19 PCD-19 Query Device-Patient Associations PCIM Device-Patient Association Consumer(DPAC) Device-Patient Association Manager (DPAM)  
DEV-20 PCD-20 Register Device PCIM Device-Patient Association Reporter (DPAR) Device-Patient Association Manager (DPAM)  
DEV-21 Communicate FHIR PHD Data POU Device Observation Reporter Device Observation Consumer Formerly PCH-01;
DEV-22 Communicate RESTful PHD Data POU Device Observation Reporter Device Observation Consumer Formerly PCH-02;
DEV-23 ... 50 (Reserved) SDPi     Note: Current SDPi (1.0) transaction count is 22; more highly possible for this version!
DEV-51 Assert Device-Patient Association State PCIM Device-Patient Association Reporter (DPAR) Device-Patient Association Manager (DPAM) Formerly PCD-17 & PCD-18
DEV-52 Report Device-Patient Association State PCIM Device-Patient Association Manager (DPAM) Device-Patient Association Consumer (DPAC)

NOTE: Hyperlinks need to be updated

Technical Framework Section Numbers for Profiles

Section Profile
3 Device Enterprise Communication (DEC)
4 Point-of-Care Infusion Verification (PIV)
5 Implantable Device - Cardiac - Observation
6 Alert Communication Management (ACM)
7 Infusion Pump Event Communication (IPEC)
8 Reserved - Point-of-Care Identity Management (PCIM)
9 Reserved - Personal Health Device Observation Upload (POU)
10 Reserved - Service-oriented Device Point-of-care Interoperability - Plug-and-trust (SDPi-P)
11 Reserved - Service-oriented Device Point-of-care Interoperability - Reporting (SDPi-R)
12 Reserved - Service-oriented Device Point-of-care Interoperability - Alerting (SDPi-A)
13 Reserved - Service-oriented Device Point-of-care Interoperability - external Control (SDPi-xC)

Technical Framework Appendix Assignments

The following table identifies both published and reserved appendix sections for the IHE DEV Technical Framework:

Volume Appendix Title Status Comment
TF-0 A Actor Definitions FT
TF-0 B Transaction Descriptions FT
TF-0 B IHE Transaction Descriptions FT
TF-1 A Rosetta Terminology Mapping (RTM) FT
TF-1 A Requirements Management for Plug-and-Trust Interoperability PPC Reserved: SDPi Supplement (Pre-Public Comment)
TF-1 B ISO/IEEE 11073 SDC Requirements Coverage PPC Reserved: SDPi Supplement (Pre-Public Comment)
TF-2 A Mapping ISO/IEEE 11073 Domain Information Model to HL7 FT
TF-2 B Common Segment Descriptions FT
TF-2 C Common Data Types FT
TF-2 D Reserved FT Note: Previous content was deprecated;
TF-2 E Examples of messages FT
TF-2 F HL7 Message Profiling Convention FT
TF-2 G HL7 Implementation Notes FT
TF-2 H IHE Integration Statements FT
TF-2 I Message Transport using MLLP FT
TF-2 J Message Transport using WS* FT
TF-2 K Message Transport Using WCTP (ACM Transactions [PCD-06] and PCD-07) FT
TF-2 L Alert (Alarm) Fatigue FT
TF-2 M Infusion Pump Events FT
TF-2 A Proposed Messages TI PCIM Supplement; Clarify appendix title
TF-2 A POU Usage of FHIR Resource and RESTful FHIR API TI POU Supplement
TF-2 A Transaction Examples TI MEMDMC Supplement; Clarify appendix title
TF-2 A Transaction Examples TI MEMLS Supplement; Clarify appendix title
TF-2 A ISO/IEEE 11073 SDC Message Specifications (Normative) PPC Reserved; SDPi Supplement (Pre-Public Comment)

Public Comments Archive

You can find an archive of early public comments on PCD documents at http://forums.rsna.org/forumdisplay.php?f=347.