Difference between revisions of "DEV Technical Framework"

From IHE Wiki
Jump to navigation Jump to search
m (→‎Technical Framework Section Numbers for Profiles: Added section content back in + added SDPi reserved sections)
Line 12: Line 12:
  
 
==Current Framework Status==
 
==Current Framework Status==
  Links to current versions of all volumes of the IHE PCD Technical Framework, and current IHE PCD Framework Supplements, may be found at:  
+
  Links to current versions of all volumes of the IHE DEV Technical Framework, and current IHE DEV Framework Supplements, may be found at:  
  
[http://ihe.net/Technical_Frameworks/#pcd PCD Technical Frameworks listing on ihe.net]
+
[http://ihe.net/Technical_Frameworks/#dev DEV Technical Frameworks listing on ihe.net]
  
 
==DEV Transaction Map==
 
==DEV Transaction Map==

Revision as of 13:35, 10 July 2020

Overview

The IHE PCD Technical Framework is composed of a set of profiles that address specific integration scenarios that include at least one regulated medical device (per the PCD Charter).

Current Framework Status

Links to current versions of all volumes of the IHE DEV Technical Framework, and current IHE DEV Framework Supplements, may be found at: 

DEV Technical Frameworks listing on ihe.net

DEV Transaction Map

Many of the DEV Profiles include transactions, specified in the Technical Framework Volume 2 Transactions, which are allocated on a domain basis.

Note: That the table indicates not only the DEV-x transaction labels, but for the PCD-x transactions that are from the pre-DEV technical framework versions (1.0 to 9.0), a 2nd column is added to maintain those aliased transaction identifiers as well.

This table identifies the currently allocated transactions and the profiles to which they belong:

ID PCD ID Transaction Title Profile Source Actor Receiving Actor Notes
DEV-01 PCD-01 Communicate PCD Data DEC Device Observation Reporter (DOR) Device Observation Consumer (DOC)
DEV-02 PCD-02 Subscribe to PCD Data SPD Device Observation Consumer (DOC) Device Observation Filter (DOF)
DEV-03 PCD-03 Communicate Infusion Order PIV Infusion Order Programmer (IOP) Infusion Order Consumer (IOC)
DEV-04 PCD-04 Report Alert (Alarm) ACM Alert (Alarm) Reporter (AR) Alert (Alarm) Manager (AM) Formerly ACM-01
DEV-05 PCD-05 Report Alert (Alarm) Status ACM Alert (Alarm) Manager (AM) Alert (Alarm) Reporter (AR) Formerly ACM-02
DEV-06 PCD-06 Disseminate Alert (Alarm) ACM Alert (Alarm) Manager (AM) Alert (Alarm) Communicator (AC) Formerly ACM-03
DEV-07 PCD-07 Report Dissemination Alert (Alarm) Status ACM Alert (Alarm) Communicator (AC) Alert (Alarm) Manager (AM) Formerly ACM-04
DEV-08 PCD-08 (Reserved) ACM      
DEV-09 PCD-09 Communicate IDC Observation IDCO Device Observation Reporter (DOR) Device Observation Consumer (DOC) IDC WG Web Page
DEV-10 PCD-10 Communicate Infusion Pump Event IPEC Device Observation Reporter (DOR) Device Observation Consumer (DOC)  
DEV-11 PCD-11 (Reserved) ACM      
DEV-12 PCD-12 Retrospective Data Query RDQ Retrospective Data Consumer (RDC) Retrospective Data Reporter(RDR)  
DEV-13 PCD-13 Retrospective Data Reply RDQ Retrospective Data Reporter(RDR) Retrospective Data Consumer (RDC)  
DEV-14 PCD-14 (Reserved)        
DEV-15 PCD-15 Device Management Information Observation (DMIO) MEMDMC Device Management Information Reporter (DMIR) Device Management Information Consumer (DMIC)  
DEV-16 PCD-16 Report Location Observation (RLO) MEMLS Location Observation Reporter (LOR) Location Observation Consumer (LOC)  
DEV-17 PCD-17 Assert Device-Patient Association PCIM Device-Patient Association Reporter (DPAR) Device-Patient Association Manager (DPAM) Deprecated, use DEV-51;
DEV-18 PCD-18 Assert Device-Patient Disassociation PCIM Device-Patient Association Reporter (DPAR) Device-Patient Association Manager (DPAM) Deprecated, use DEV-51;
DEV-19 PCD-19 Query Device-Patient Associations PCIM Device-Patient Association Consumer(DPAC) Device-Patient Association Manager (DPAM)  
DEV-20 PCD-20 Register Device PCIM Device-Patient Association Reporter (DPAR) Device-Patient Association Manager (DPAM)  
DEV-21 Communicate FHIR PHD Data POU Device Observation Reporter Device Observation Consumer Formerly PCH-01;
DEV-22 Communicate RESTful PHD Data POU Device Observation Reporter Device Observation Consumer Formerly PCH-02;
DEV-23 ... 50 (Reserved) SDPi     Note: Current SDPi (1.0) transaction count is 22; more highly possible for this version!
DEV-51 Assert Device-Patient Association State PCIM Device-Patient Association Reporter (DPAR) Device-Patient Association Manager (DPAM) Formerly PCD-17 & PCD-18
DEV-52 Report Device-Patient Association State PCIM Device-Patient Association Manager (DPAM) Device-Patient Association Consumer (DPAC)

NOTE: Hyperlinks need to be updated

Technical Framework Section Numbers for Profiles

Section Profile
3 Device Enterprise Communication (DEC)
4 Point-of-Care Infusion Verification (PIV)
5 Implantable Device - Cardiac - Observation
6 Alert Communication Management (ACM)
7 Infusion Pump Event Communication (IPEC)
8 Reserved - Point-of-Care Identity Management (PCIM)
9 Reserved - Personal Health Device Observation Upload (POU)
10 Reserved - Service-oriented Device Point-of-care Interoperability - Plug-and-trust (SDPi-P)
11 Reserved - Service-oriented Device Point-of-care Interoperability - Reporting (SDPi-R)
12 Reserved - Service-oriented Device Point-of-care Interoperability - Alerting (SDPi-A)
13 Reserved - Service-oriented Device Point-of-care Interoperability - external Control (SDPi-xC)

Public Comments Archive

You can find an archive of early public comments on PCD documents at http://forums.rsna.org/forumdisplay.php?f=347.