Difference between revisions of "Card Tech Minutes 2012.02.22"

From IHE Wiki
Jump to navigation Jump to search
(Created page with "=== Attendees === * Duncan Wood (Medical Micrographics) * Harry Solomon (GE) * Nick Gawrit (heartbase) * Chris Melo ( Philips) === Agenda === editorial discussion on document ...")
 
 
(One intermediate revision by the same user not shown)
Line 3: Line 3:
 
* Duncan Wood (Medical Micrographics)
 
* Duncan Wood (Medical Micrographics)
 
* Harry Solomon (GE)
 
* Harry Solomon (GE)
* Nick Gawrit (heartbase)
+
* Nick Gawrit (Heartbase)
 
* Chris Melo ( Philips)
 
* Chris Melo ( Philips)
 +
* Anthony Scinicariello (St. Jude)
  
 
=== Agenda ===
 
=== Agenda ===
editorial discussion on document structure
+
* editorial discussion on document structure
guidelines agreed on reorganizing the CDA document - move certain document-wide data from procedure to header section
+
** guidelines agreed on reorganizing the CDA document - move certain document-wide data from procedure to header section
decision to NOT inherit completely from C-CDA, but to align with it. this is because we cannot restrict IHE profiles to a US-Realm.  
+
** decision to NOT inherit completely from C-CDA, but to align with it. This is because we cannot restrict IHE profiles to a US-Realm.  
As soon as C-CDA addresses the US-Realm issue we can look to direct inheritence then in TF maintenance.
+
*** As soon as C-CDA addresses the US-Realm issue we can look to direct inheritence then in TF maintenance.
 +
 
 +
=== Notes ===
 +
* Chris presented draft header element constraints for CRC which included the full list from the C-CDA header and the C-CDA Procedure Note header and additional constraints will be added based on CIRC header constraints and Cath constraints
 +
** CRC will explicitly state that it is agnostic of realmCode – so it could, using national extensions, be used as US-realm or Universal realm.
 +
** CRC will have a separate template Id and not include C-CDA procedure note or CIRC document template Ids, since it is specific to Cath reporting.
 +
** Constraints will be re-used with the same conformance ID if and only if they remain unchanged from the C-CDA or CIRC constraints.
 +
** These header constraints will be reviewed individually and one complete list will be provided for the CRC header.
 +
* CRC header element review – Nick had made a proposal of the mapping of NCDR CathPCI registry codes to CRC header elements.  This set of data elements was reviewed and
 +
** several were mapped to specific header elements.  These header elements that will be included in the CDA header do not need SNOMED codes – they will just use the CDA element names.
 +
** several were deemed to be national extensions so should not be included in CRC
 +
** several were deemed to be not applicable for a cath report
 +
** some are included in body sections and are not included in the header
 +
* Harry agreed to begin work on the conversion of CIRC sections to align with the C-CDA section templates and will focus on Medical History Section for next week

Latest revision as of 12:53, 12 March 2012

Attendees

  • Duncan Wood (Medical Micrographics)
  • Harry Solomon (GE)
  • Nick Gawrit (Heartbase)
  • Chris Melo ( Philips)
  • Anthony Scinicariello (St. Jude)

Agenda

  • editorial discussion on document structure
    • guidelines agreed on reorganizing the CDA document - move certain document-wide data from procedure to header section
    • decision to NOT inherit completely from C-CDA, but to align with it. This is because we cannot restrict IHE profiles to a US-Realm.
      • As soon as C-CDA addresses the US-Realm issue we can look to direct inheritence then in TF maintenance.

Notes

  • Chris presented draft header element constraints for CRC which included the full list from the C-CDA header and the C-CDA Procedure Note header and additional constraints will be added based on CIRC header constraints and Cath constraints
    • CRC will explicitly state that it is agnostic of realmCode – so it could, using national extensions, be used as US-realm or Universal realm.
    • CRC will have a separate template Id and not include C-CDA procedure note or CIRC document template Ids, since it is specific to Cath reporting.
    • Constraints will be re-used with the same conformance ID if and only if they remain unchanged from the C-CDA or CIRC constraints.
    • These header constraints will be reviewed individually and one complete list will be provided for the CRC header.
  • CRC header element review – Nick had made a proposal of the mapping of NCDR CathPCI registry codes to CRC header elements. This set of data elements was reviewed and
    • several were mapped to specific header elements. These header elements that will be included in the CDA header do not need SNOMED codes – they will just use the CDA element names.
    • several were deemed to be national extensions so should not be included in CRC
    • several were deemed to be not applicable for a cath report
    • some are included in body sections and are not included in the header
  • Harry agreed to begin work on the conversion of CIRC sections to align with the C-CDA section templates and will focus on Medical History Section for next week