Difference between revisions of "1.3.6.1.4.1.19376.1.3.1.2"

From IHE Wiki
Jump to navigation Jump to search
Line 57: Line 57:
  
 
=====<code code=" " codeSystem=" " codeSystemName=" " displayName=" "/>=====
 
=====<code code=" " codeSystem=" " codeSystemName=" " displayName=" "/>=====
Specimen Collection MAY contain a unique code from an international standard, such as LOINC.
+
Specimen Collection SHALL contain a unique code from an international standard, such as LOINC.
  
 
=====<effectiveTime value=" "/>=====
 
=====<effectiveTime value=" "/>=====

Revision as of 14:51, 20 June 2008

Return to: XDS-LAB Harmonization
Return to: Laboratory Content Modules
Return to: Laboratory Data Processing Entry

Development Only

The PCC Wiki Content is used only for development of IHE PCC Content. The Normative content of the PCC Technical Framework and the current supplements can be found at http://www.ihe.net/Technical_Framework/index.cfm#PCC

Trial.gif Specimen Collection 1.3.6.1.4.1.19376.1.3.1.2

Specimen Collection, when present, SHALL be recorded an <act> in an <entryRelationship> under the Laboratory Data Processing Entry as demonstrated in the figure below. The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.



Uses

See Templates using Specimen Collection

Specification
Specimen Collection Example
<ClinicalDocument>
  ...
  <component typeCode="COMP">
    <structuredBody classCode="DOCBODY" moodCode="EVN">
      <component typeCode="COMP">
        <section classCode="DOCSECT">
          <templateId extension="??" root="1.3.6.1.4.1.19376.1.3.3.2.1"/>
          ...
          <entry typeCode="DRIV">
            <templateId extension="Lab.Report.Data.Processing.Entry" root="1.3.6.1.4.1.19376.1.3.1"/>
            <act classCode="ACT" moodCode="EVN">
              ...
              <entryRelationship typeCode="COMP">
                <act classCode="ACT" moodCode="EVN">
                  <templateId extension="??" root="1.3.6.1.4.1.19376.1.3.1.2"/>
                  <code code="33882-2" codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC" 
                        displayName="Collection"/>
                  <effectiveTime value="20071108000000.0000-0500"/>
                  <participant typeCode="PRF">
                    <participantRole>
                      <addr>
                        <streetAddressLine>7000 Hosptial Drive</streetAddressLine>
                        <city>Chicago</city>
                        <state>IL</state>
                        <postalCode>60622</postalCode>
                      </addr>
                      <telecom value="tel: 312-555-5555"/>
                    </participantRole>
                  </participant>
                </act>
              </entryRelationship>
              ...
            </act>
          </entry>
        </section>
      </component>
      ...
    </structuredBody>
  </component>
</ClinicalDocument>


<templateId extension="??" root="1.3.6.1.4.1.19376.1.3.1.2"/>

The <templateId> element identifies this <act> as the Specimen Collection. The templateId SHALL be recorded as shown above, root="1.3.6.1.4.1.19376.1.3.1.2".

Specimen Collection SHALL contain a unique code from an international standard, such as LOINC.

<effectiveTime value=" "/>

Specimen Collection SHALL contain the date and time of collection.

<participant typeCode="PRF">

Specimen Collection MAY contain the collecting participant.