1.3.6.1.4.1.19376.1.3.1

From IHE Wiki
Revision as of 13:26, 24 June 2008 by Srrenly (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Return to: XDS-LAB Harmonization
Return to: Laboratory Content Modules

Development Only

The PCC Wiki Content is used only for development of IHE PCC Content. The Normative content of the PCC Technical Framework and the current supplements can be found at http://www.ihe.net/Technical_Framework/index.cfm#PCC

Trial.gif Laboratory Report Data Processing Entry 1.3.6.1.4.1.19376.1.3.1

At least one Lab Report Data Processing Entry shall be present. The <entry> SHALL contain a single <act> sub-element. This <act> is hereafter referred to as the Specimen Act.


The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.


Uses

See Templates using Laboratory Report Data Processing Entry

Specification
Laboratory Report Data Processing Entry Example
<entry typeCode="DRIV">
  <templateId root="1.3.6.1.4.1.19376.1.3"/>
  <act classCode="ACT" moodCode="EVN">
    <statusCode code="completed"/>
    ...
  </act>
</entry>


<templateId root="1.3.6.1.4.1.19376.1.3.1"/>

The <templateId> element identifies this <entry> as a Laboratory Report Data Processing Entry. The templateId SHALL be recorded as shown above, root="1.3.6.1.4.1.19376.1.3.1".

<act classCode="ACT" moodCode="EVN"/>

There shall be one Act sub-element. This <act> is hereafter referred to as the Specimen Act. This sub-element uses the following modules conforming to the following requirements. These modules, when present, shall be recorded as <entryRelationship> elements under the Specimen Act.

Modules unique to the document body
Sub-Element Opt Description
1.3.6.1.4.1.19376.1.3.1.1 R2 Notification Organizer
1.3.6.1.4.1.19376.1.3.1.1.1 R2 Notifiable Condition
1.3.6.1.4.1.19376.1.3.1.1.2 R2 Case Identifier
1.3.6.1.4.1.19376.1.3.1.1.3 R2 Outbreak Identifier
1.3.6.1.4.1.19376.1.3.1.2 R2 Specimen Collection
1.3.6.1.4.1.19376.1.3.1.3 R2 Specimen Received
1.3.6.1.4.1.19376.1.3.1.4 R2 Laboratory Battery Organizer
1.3.6.1.4.1.19376.1.3.1.5 R2 Laboratory Isolate Organizer
1.3.6.1.4.1.19376.1.3.1.6 R Laboratory Observation
1.3.6.1.4.1.19376.1.5.3.1.4.2 O Annotation Comment (PCC)


Modules with counterparts in the cda header
Sub-Element Opt Description
1.3.6.1.4.1.19376.1.3.3.1.2.1 R2 Non-Human Subject
1.3.6.1.4.1.19376.1.3.3.1.3.1 R2 Human Patient with Non-Human Subject
1.3.6.1.4.1.19376.1.3.3.1.5 O Laboratory Result Verifier
1.3.6.1.4.1.19376.1.3.3.1.7 O Laboratory Performer