Trial.gif Specimen Site 1.3.6.1.4.1.19376.1.3.1.8

Specimen Site, when present, SHALL be recorded an <act> in an <entryRelationship> under the Laboratory Data Processing Entry as demonstrated in the figure below. The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.



Uses

See Templates using Specimen Site

Specification
Specimen Site Example
<ClinicalDocument>
  ...
  <component typeCode="COMP">
    <structuredBody classCode="DOCBODY" moodCode="EVN">
      <component typeCode="COMP">
        <section classCode="DOCSECT">
          <templateId root="1.3.6.1.4.1.19376.1.3.3.2.1"/>
          ...
          <entry typeCode="DRIV">
            <templateId root="1.3.6.1.4.1.19376.1.3.1"/>
            <act classCode="ACT" moodCode="EVN">
              ...
              <specimen typeCode="SPC">
                <specimenRole classCode="SPEC">
                  <id extension="5555" root="1.3.6.1.4.1.19376.1.3.4"/>
                  <specimenPlayingEntity>
                    <code code="BLD" codeSystem="2.16.840.1.113883.5.129" codeSystemName="HL7" displayName="Blood"/>
                  </specimenPlayingEntity>
                </specimenRole>
              </specimen>
              ...
              <entryRelationship typeCode="">
                <procedure classCode="PROC" moodCode="EVN">
                  <templateId root="1.3.6.1.4.1.19376.1.3.1.8"/>
                  <effectiveTime value="20080404000000.0000-0400"/>
                  <targetSiteCode code="T-D079D" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT" displayName="Elbow"/>
                  <specimen typeCode="SPC">
                    <specimenRole classCode="SPEC">
                      <id extension="5555" root="1.3.6.1.4.1.19376.1.3.4"/>
                    </specimenRole>
                  </specimen>
                </procedure>
              </entryRelationship>
              ...
            </act>
          </entry>
        </section>
      </component>
      ...
    </structuredBody>
  </component>
</ClinicalDocument>


<templateId root="1.3.6.1.4.1.19376.1.3.1.8"/>

The <templateId> element identifies this <act> as the Specimen Site. The templateId SHALL be recorded as shown above, root="1.3.6.1.4.1.19376.1.3.1.8".

<effectiveTime value=" "/>

The Specimen Site time value MAY be present.

<targetSiteCode/>

The Specimen Site SHALL contain a unique code from an international standard, such as SNOMED.

<specimen/>

Specimen Site SHALL include the <specimen> element holding <id> when more than ONE <specimen> is listed.